Silver Nanoparticles and Polydimethylsiloxane-coated Paper for the Simultaneous Detection of Ascorbic Acid and Hydroquinone

IF 2.7 4区 化学 Q2 CHEMISTRY, INORGANIC & NUCLEAR
Nutthaya Butwong, Siriboon Mukdasai, Pimpanitpa Kunthadong, Kamolwan Rintramee, Thidarat Kunawong
{"title":"Silver Nanoparticles and Polydimethylsiloxane-coated Paper for the Simultaneous Detection of Ascorbic Acid and Hydroquinone","authors":"Nutthaya Butwong,&nbsp;Siriboon Mukdasai,&nbsp;Pimpanitpa Kunthadong,&nbsp;Kamolwan Rintramee,&nbsp;Thidarat Kunawong","doi":"10.1007/s10876-024-02697-8","DOIUrl":null,"url":null,"abstract":"<div><p>This study developed a novel paper-based sensor for the simultaneous analysis of ascorbic acid (AA) and hydroquinone (HQ). The sensor utilized polyvinyl alcohol (PVA)-stabilized silver nanoparticles (AgNPs-PVA) as the reagent probe and PVA media acted as the filter for separation of the analytes. Polydimethylsiloxane (PDMS) and ethanol serve as the stationary phase and eluent, respectively, exploiting the differences in analyte reactions and solubility to achieve their separation on the filter paper. The circular sensor’s central zone was AA’s detection area, while HQ was detected in the outer ring region. AA induced an immediate color change in the test kit, whereas HQ required a 20-minute elution with ethanol followed by colorimetric analysis. All analytes exhibited relative standard deviations of repeatability and reproducibility below 2.7% and 9.5%, respectively. Under optimal conditions, the linear detection range for HQ was 0.2-2.0 mg⋅L<sup>− 1</sup>, while AA was 0.1-2.0 mg⋅L<sup>− 1</sup>. The detection limit was determined to be 0.05 mg⋅L<sup>− 1</sup> for AA and 0.1 mg⋅L<sup>− 1</sup> for HQ. The recoveries of AA and HQ in cosmetic cream samples ranged from 80 to 110%. The accuracy of the sensor’s measurements was further validated by comparison with the HPLC-DAD method.</p></div>","PeriodicalId":618,"journal":{"name":"Journal of Cluster Science","volume":"35 8","pages":"2837 - 2848"},"PeriodicalIF":2.7000,"publicationDate":"2024-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cluster Science","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s10876-024-02697-8","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, INORGANIC & NUCLEAR","Score":null,"Total":0}
引用次数: 0

Abstract

This study developed a novel paper-based sensor for the simultaneous analysis of ascorbic acid (AA) and hydroquinone (HQ). The sensor utilized polyvinyl alcohol (PVA)-stabilized silver nanoparticles (AgNPs-PVA) as the reagent probe and PVA media acted as the filter for separation of the analytes. Polydimethylsiloxane (PDMS) and ethanol serve as the stationary phase and eluent, respectively, exploiting the differences in analyte reactions and solubility to achieve their separation on the filter paper. The circular sensor’s central zone was AA’s detection area, while HQ was detected in the outer ring region. AA induced an immediate color change in the test kit, whereas HQ required a 20-minute elution with ethanol followed by colorimetric analysis. All analytes exhibited relative standard deviations of repeatability and reproducibility below 2.7% and 9.5%, respectively. Under optimal conditions, the linear detection range for HQ was 0.2-2.0 mg⋅L− 1, while AA was 0.1-2.0 mg⋅L− 1. The detection limit was determined to be 0.05 mg⋅L− 1 for AA and 0.1 mg⋅L− 1 for HQ. The recoveries of AA and HQ in cosmetic cream samples ranged from 80 to 110%. The accuracy of the sensor’s measurements was further validated by comparison with the HPLC-DAD method.

用于同时检测抗坏血酸和对苯二酚的银纳米粒子和聚二甲基硅氧烷涂层纸
本研究开发了一种新型纸基传感器,用于同时分析抗坏血酸(AA)和对苯二酚(HQ)。该传感器利用聚乙烯醇(PVA)稳定银纳米粒子(AgNPs-PVA)作为试剂探针,聚乙烯醇介质作为分离分析物的过滤器。聚二甲基硅氧烷(PDMS)和乙醇分别作为固定相和洗脱剂,利用分析物反应和溶解度的差异实现它们在滤纸上的分离。圆形传感器的中心区域是 AA 的检测区域,而 HQ 则在外圈区域检测。AA 在检测试剂盒中会立即变色,而 HQ 则需要用乙醇洗脱 20 分钟后才能进行比色分析。所有分析物的重复性和再现性的相对标准偏差分别低于 2.7% 和 9.5%。在最佳条件下,HQ 的线性检测范围为 0.2-2.0 mg-L-1,AA 为 0.1-2.0 mg-L-1。AA 和 HQ 的检测限分别为 0.05 mg⋅L- 1 和 0.1 mg⋅L- 1。化妆品膏霜样品中 AA 和 HQ 的回收率为 80% 至 110%。通过与 HPLC-DAD 方法进行比较,进一步验证了传感器测量的准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Cluster Science
Journal of Cluster Science 化学-无机化学与核化学
CiteScore
6.70
自引率
0.00%
发文量
166
审稿时长
3 months
期刊介绍: The journal publishes the following types of papers: (a) original and important research; (b) authoritative comprehensive reviews or short overviews of topics of current interest; (c) brief but urgent communications on new significant research; and (d) commentaries intended to foster the exchange of innovative or provocative ideas, and to encourage dialogue, amongst researchers working in different cluster disciplines.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信