The effects of electronic cigarette smoking on retinal nerve fiber layer, ganglion cell layer, inner plexiform layer, and choroidal thickness.

IF 1.6 4区 医学 Q3 OPHTHALMOLOGY
Dharshini Balasubaramaniam, Yi Wen Lim, Shamala Retnasabapathy, Fazilawati A Qamarruddin, Sujaya Singh
{"title":"The effects of electronic cigarette smoking on retinal nerve fiber layer, ganglion cell layer, inner plexiform layer, and choroidal thickness.","authors":"Dharshini Balasubaramaniam, Yi Wen Lim, Shamala Retnasabapathy, Fazilawati A Qamarruddin, Sujaya Singh","doi":"10.1080/15569527.2024.2423265","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare the thickness of the retinal nerve fibre layer (RNFL), ganglion cell layer (GCL), inner plexiform layer (IPL), and choroid in healthy electronic cigarette smokers and non-smokers using spectral domain optical coherence tomography (SD-OCT).</p><p><strong>Material and method: </strong>25 healthy electronic cigarette smokers and 25 age- and gender-matched healthy non-smokers were included in the study. RNFL, GCL, IPL and choroidal thickness were measured by SD-OCT using an automated programme. After normality tests, an independent sample <i>t</i>-test was used to analyse the differences in RNFL, GCL, IPL, and choroidal thickness values between the groups.</p><p><strong>Results: </strong>The mean age of electronic cigarette smokers and non-smokers was 33.68 and 33.64 years, respectively. The mean smoking history was 6.6 years (range 5-8 years). Most of the participants smoked 2-5 ml of e-liquid per day (52%), while 36% smoked more than 5 ml and 12% smoked less than 2 ml per day. The mean intraocular pressure in the electronic cigarette smoker group was 15.0 mmHg, while the non-smoker group was 15.32 mmHg. The mean axial length in the electronic cigarette smoker group and non-smoker group was 23.36 and 23.63 mm, respectively. No significant difference was observed regarding RNFL, GCL, IPL or choroidal thickness between both groups.</p><p><strong>Conclusion: </strong>The thickness of the RNFL, GCL, IPL, and choroid was found to be similar in both the healthy electronic cigarette smokers and non-smokers groups.</p>","PeriodicalId":11023,"journal":{"name":"Cutaneous and Ocular Toxicology","volume":" ","pages":"1-6"},"PeriodicalIF":1.6000,"publicationDate":"2024-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cutaneous and Ocular Toxicology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/15569527.2024.2423265","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To compare the thickness of the retinal nerve fibre layer (RNFL), ganglion cell layer (GCL), inner plexiform layer (IPL), and choroid in healthy electronic cigarette smokers and non-smokers using spectral domain optical coherence tomography (SD-OCT).

Material and method: 25 healthy electronic cigarette smokers and 25 age- and gender-matched healthy non-smokers were included in the study. RNFL, GCL, IPL and choroidal thickness were measured by SD-OCT using an automated programme. After normality tests, an independent sample t-test was used to analyse the differences in RNFL, GCL, IPL, and choroidal thickness values between the groups.

Results: The mean age of electronic cigarette smokers and non-smokers was 33.68 and 33.64 years, respectively. The mean smoking history was 6.6 years (range 5-8 years). Most of the participants smoked 2-5 ml of e-liquid per day (52%), while 36% smoked more than 5 ml and 12% smoked less than 2 ml per day. The mean intraocular pressure in the electronic cigarette smoker group was 15.0 mmHg, while the non-smoker group was 15.32 mmHg. The mean axial length in the electronic cigarette smoker group and non-smoker group was 23.36 and 23.63 mm, respectively. No significant difference was observed regarding RNFL, GCL, IPL or choroidal thickness between both groups.

Conclusion: The thickness of the RNFL, GCL, IPL, and choroid was found to be similar in both the healthy electronic cigarette smokers and non-smokers groups.

吸电子烟对视网膜神经纤维层、神经节细胞层、内丛状层和脉络膜厚度的影响。
目的:使用光谱域光学相干断层扫描(SD-OCT)比较健康电子烟吸烟者和非吸烟者的视网膜神经纤维层(RNFL)、神经节细胞层(GCL)、内丛状层(IPL)和脉络膜的厚度。使用自动程序通过 SD-OCT 测量 RNFL、GCL、IPL 和脉络膜厚度。经过正态性检验后,采用独立样本 t 检验分析各组间 RNFL、GCL、IPL 和脉络膜厚度值的差异:电子烟吸烟者和非吸烟者的平均年龄分别为 33.68 岁和 33.64 岁。平均吸烟史为 6.6 年(5-8 年不等)。大多数参与者(52%)每天吸 2-5 毫升电子烟液,36% 吸 5 毫升以上,12% 吸 2 毫升以下。电子烟吸食者组的平均眼压为 15.0 毫米汞柱,而非吸食者组为 15.32 毫米汞柱。电子烟吸烟者组和非吸烟者组的平均眼轴长度分别为 23.36 毫米和 23.63 毫米。两组的 RNFL、GCL、IPL 或脉络膜厚度均无明显差异:结论:健康的电子烟吸烟者组和非吸烟者组的 RNFL、GCL、IPL 和脉络膜厚度相似。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.30
自引率
6.20%
发文量
40
审稿时长
1 months
期刊介绍: Cutaneous and Ocular Toxicology is an international, peer-reviewed journal that covers all types of harm to cutaneous and ocular systems. Areas of particular interest include pharmaceutical and medical products; consumer, personal care, and household products; and issues in environmental and occupational exposures. In addition to original research papers, reviews and short communications are invited, as well as concise, relevant, and critical reviews of topics of contemporary significance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信