Joo Myung Lee, Seung Hun Lee, Woochan Kwon, Han Byul Kim, David Hong, Hyun Kuk Kim, Sang-Geon Cho, Doosup Shin, Ki Seong Park, Jahae Kim, Jang Bae Moon, Ho-Chun Song, Seungrok Lee, Dong-Heon Ha, Jinah Jang, Youngkeun Ahn, Myung Ho Jeong, Ki Hong Choi, Taek Kyu Park, Jeong Hoon Yang, Young Bin Song, Joo-Yong Hahn, Seung-Hyuk Choi, Hyeon-Cheol Gwon, Young Joon Hong
{"title":"Experimental validation of coronary stenosis severity and development of ischemic myocardium.","authors":"Joo Myung Lee, Seung Hun Lee, Woochan Kwon, Han Byul Kim, David Hong, Hyun Kuk Kim, Sang-Geon Cho, Doosup Shin, Ki Seong Park, Jahae Kim, Jang Bae Moon, Ho-Chun Song, Seungrok Lee, Dong-Heon Ha, Jinah Jang, Youngkeun Ahn, Myung Ho Jeong, Ki Hong Choi, Taek Kyu Park, Jeong Hoon Yang, Young Bin Song, Joo-Yong Hahn, Seung-Hyuk Choi, Hyeon-Cheol Gwon, Young Joon Hong","doi":"10.1016/j.rec.2024.10.006","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction and objectives: </strong>The current study aimed to evaluate the causal association between hemodynamically significant stenosis and the occurrence of ischemic myocardium using an experimental animal model of coronary artery stenosis.</p><p><strong>Methods: </strong>In Yorkshire swine (n = 10), coronary stenosis in the left anterior descending artery was induced using a customized vascular occluder to create varying degrees of occlusion severity (40%-99%). Serial changes in coronary pressure and flow velocity were measured in the left anterior descending artery before and after the implantation of the vascular occluder. At 1 month, 13N-ammonia positron emission tomography (PET) was performed, followed by the collection of isolated hearts for 2,3,5-Triphenyltetrazolium chloride (TTC) staining to quantify the percent area of necrotic myocardium. Three animals in the control group were evaluated using the same protocols, but without the implantation of a vascular occluder Results: The median diameter stenosis after vascular occluder implantation was 61.3% (Q1-Q3: 55.9%-72.3%). Significant differences were observed in hyperemic stenosis resistance, fractional flow reserve (FFR), stress perfusion defect and reversibility in PET, as well as in necrotic myocardium in TTC staining based on stenosis severity (control group: < 50%, 50%-70%, 70%-90%, and > 90%) (all P < .010). Animals with FFR < 0.75 at 1 month exhibited a significantly higher area of stress perfusion defect (30.7 ± 3.1% vs 6.0 ± 4.2%, P < .001), reversibility in PET (11.0 ± 4.0% vs 0.0 ± 0.0%, P = .006), and necrotic myocardium in TTC staining (15.8 ± 6.4% vs 0.0 ± 0.0%, P < .001) than those with FFR ≥ 0.75.</p><p><strong>Conclusions: </strong>In a porcine model, the induction of hemodynamically significant stenosis with FFR < 0.75 was associated with the development of stress perfusion defects and reversibility in PET, as well as necrotic myocardium identified by pathology.</p>","PeriodicalId":38430,"journal":{"name":"Revista española de cardiología (English ed.)","volume":" ","pages":""},"PeriodicalIF":7.2000,"publicationDate":"2024-10-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista española de cardiología (English ed.)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.rec.2024.10.006","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction and objectives: The current study aimed to evaluate the causal association between hemodynamically significant stenosis and the occurrence of ischemic myocardium using an experimental animal model of coronary artery stenosis.
Methods: In Yorkshire swine (n = 10), coronary stenosis in the left anterior descending artery was induced using a customized vascular occluder to create varying degrees of occlusion severity (40%-99%). Serial changes in coronary pressure and flow velocity were measured in the left anterior descending artery before and after the implantation of the vascular occluder. At 1 month, 13N-ammonia positron emission tomography (PET) was performed, followed by the collection of isolated hearts for 2,3,5-Triphenyltetrazolium chloride (TTC) staining to quantify the percent area of necrotic myocardium. Three animals in the control group were evaluated using the same protocols, but without the implantation of a vascular occluder Results: The median diameter stenosis after vascular occluder implantation was 61.3% (Q1-Q3: 55.9%-72.3%). Significant differences were observed in hyperemic stenosis resistance, fractional flow reserve (FFR), stress perfusion defect and reversibility in PET, as well as in necrotic myocardium in TTC staining based on stenosis severity (control group: < 50%, 50%-70%, 70%-90%, and > 90%) (all P < .010). Animals with FFR < 0.75 at 1 month exhibited a significantly higher area of stress perfusion defect (30.7 ± 3.1% vs 6.0 ± 4.2%, P < .001), reversibility in PET (11.0 ± 4.0% vs 0.0 ± 0.0%, P = .006), and necrotic myocardium in TTC staining (15.8 ± 6.4% vs 0.0 ± 0.0%, P < .001) than those with FFR ≥ 0.75.
Conclusions: In a porcine model, the induction of hemodynamically significant stenosis with FFR < 0.75 was associated with the development of stress perfusion defects and reversibility in PET, as well as necrotic myocardium identified by pathology.