{"title":"\"Brain Biopsy Revolution: Unveiling the Core Syringe Technique with Clinical Insights\".","authors":"Mohammed Bafaquh, Noor Alghanuim, Gmaan Alzhrani, Fatimah A Alghabban, Arwa S AlShamekh, Mohammed Daghriri, Othman T Almutairi, Sarah Bin Abdulqader, Lahbib Soualmi, Najeeb Alomar, Khulood K Alraddadi, Fahd R AlSubaie","doi":"10.1016/j.wneu.2024.10.103","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Obtaining a definitive pathological diagnosis from brain tissue sampling was challenging due to the small, non-representative sample. This study introduced a novel syringe technique for brain biopsy aimed at enhancing diagnostic accuracy by obtaining core tissue samples that better represent the targeted tissue.</p><p><strong>Methods: </strong>The ten patients with atypical brain lesions underwent the syringe biopsy. After meticulous preoperative planning with neuronavigation, a minimally invasive approach was used: a 3 cm skin incision and a 14 mm burr hole were created. A modified 3-cc syringe was used to create negative pressure and cannulate the brain tissue. The desired sample size (24 cm³) was obtained by controlling the syringe depth and withdrawal. Medical records were reviewed to assess sample analysis results and any complications.</p><p><strong>Results: </strong>The syringe technique successfully yielded adequate tissue samples in 9 out of 10 patients. In one case, the desired tissue could not be retrieved and required a microsurgical approach for removal. In all ten cases, a correct diagnosis was made without significant complications.</p><p><strong>Conclusion: </strong>The preliminary findings suggest that the syringe technique is both safe and effective for obtaining substantial volumes of brain tissue, facilitating accurate pathological evaluation in cases of complex neurological disorders.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.wneu.2024.10.103","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Obtaining a definitive pathological diagnosis from brain tissue sampling was challenging due to the small, non-representative sample. This study introduced a novel syringe technique for brain biopsy aimed at enhancing diagnostic accuracy by obtaining core tissue samples that better represent the targeted tissue.
Methods: The ten patients with atypical brain lesions underwent the syringe biopsy. After meticulous preoperative planning with neuronavigation, a minimally invasive approach was used: a 3 cm skin incision and a 14 mm burr hole were created. A modified 3-cc syringe was used to create negative pressure and cannulate the brain tissue. The desired sample size (24 cm³) was obtained by controlling the syringe depth and withdrawal. Medical records were reviewed to assess sample analysis results and any complications.
Results: The syringe technique successfully yielded adequate tissue samples in 9 out of 10 patients. In one case, the desired tissue could not be retrieved and required a microsurgical approach for removal. In all ten cases, a correct diagnosis was made without significant complications.
Conclusion: The preliminary findings suggest that the syringe technique is both safe and effective for obtaining substantial volumes of brain tissue, facilitating accurate pathological evaluation in cases of complex neurological disorders.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.