Nanosilver and Graphene Oxide Modified Screen-Printed Carbon Electrode for Electrochemical Detection of Bisphenol A

IF 1 4区 化学 Q4 CHEMISTRY, ANALYTICAL
H. Wan, X. Xie, H. Liu, S. Mahmud, H. Liu
{"title":"Nanosilver and Graphene Oxide Modified Screen-Printed Carbon Electrode for Electrochemical Detection of Bisphenol A","authors":"H. Wan,&nbsp;X. Xie,&nbsp;H. Liu,&nbsp;S. Mahmud,&nbsp;H. Liu","doi":"10.1134/S1061934824701077","DOIUrl":null,"url":null,"abstract":"<p>In this study, a highly sensitive electrochemical sensor for the detection of bisphenol A (BPA) was developed by modifying a screen-printed carbon electrode (SPCE) with silver nanoparticles (AgNPs) and graphene oxide (GO) composites. The electrochemical properties of the modified electrode interface were meticulously investigated through cyclic voltammetry (CV) and electrochemical impedance spectroscopy, employing 1.0 mM [Fe(CN)<sub>6</sub>]<sup>3–</sup>/[Fe(CN)<sub>6</sub>]<sup>4–</sup> as a redox probe. The findings demonstrate that the AgNPs/GO/SPCE composite exhibits superior electrical conductivity and facilitates rapid electron transfer compared to both GO/SPCE and SPCE alone. The electrochemical behavior of BPA on the AgNPs/GO/SPCE electrode was comprehensively studied using CV, revealing exceptional electrocatalytic properties for BPA oxidation. To assess the analytical performance, differential pulse voltammetry was employed. Results unequivocally show a significant improvement in the electrochemical responses when using AgNPs/GO/SPCE. Calibration curves exhibited linear ranges of 0.25–2.19 μM with a remarkable limit of detection of 0.046 μM for BPA. Furthermore, the established method was applied for the determination of BPA in plastic products, achieving satisfactory reproducibility and recovery. This novel AgNPs/GO/SPCE-based sensor holds promise for the sensitive and reliable detection of BPA in various environmental and industrial applications.</p>","PeriodicalId":606,"journal":{"name":"Journal of Analytical Chemistry","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1134/S1061934824701077","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

In this study, a highly sensitive electrochemical sensor for the detection of bisphenol A (BPA) was developed by modifying a screen-printed carbon electrode (SPCE) with silver nanoparticles (AgNPs) and graphene oxide (GO) composites. The electrochemical properties of the modified electrode interface were meticulously investigated through cyclic voltammetry (CV) and electrochemical impedance spectroscopy, employing 1.0 mM [Fe(CN)6]3–/[Fe(CN)6]4– as a redox probe. The findings demonstrate that the AgNPs/GO/SPCE composite exhibits superior electrical conductivity and facilitates rapid electron transfer compared to both GO/SPCE and SPCE alone. The electrochemical behavior of BPA on the AgNPs/GO/SPCE electrode was comprehensively studied using CV, revealing exceptional electrocatalytic properties for BPA oxidation. To assess the analytical performance, differential pulse voltammetry was employed. Results unequivocally show a significant improvement in the electrochemical responses when using AgNPs/GO/SPCE. Calibration curves exhibited linear ranges of 0.25–2.19 μM with a remarkable limit of detection of 0.046 μM for BPA. Furthermore, the established method was applied for the determination of BPA in plastic products, achieving satisfactory reproducibility and recovery. This novel AgNPs/GO/SPCE-based sensor holds promise for the sensitive and reliable detection of BPA in various environmental and industrial applications.

Abstract Image

用于电化学检测双酚 A 的纳米银和石墨烯氧化物改性丝网印刷碳电极
本研究通过用银纳米颗粒(AgNPs)和氧化石墨烯(GO)复合材料修饰丝网印刷碳电极(SPCE),开发了一种用于检测双酚 A(BPA)的高灵敏度电化学传感器。采用 1.0 mM [Fe(CN)6]3-/[Fe(CN)6]4- 作为氧化还原探针,通过循环伏安法 (CV) 和电化学阻抗谱仔细研究了改性电极界面的电化学特性。研究结果表明,与单独的 GO/SPCE 和 SPCE 相比,AgNPs/GO/SPCE 复合材料具有更优越的导电性,并能促进电子的快速转移。利用 CV 对 AgNPs/GO/SPCE 电极上双酚 A 的电化学行为进行了全面研究,结果表明该电极对双酚 A 氧化具有优异的电催化性能。为了评估分析性能,采用了差分脉冲伏安法。结果明确显示,使用 AgNPs/GO/SPCE 时,电化学反应明显改善。校准曲线的线性范围为 0.25-2.19 μM,双酚 A 的检出限为 0.046 μM。此外,该方法还被应用于塑料制品中双酚 A 的测定,并取得了令人满意的重现性和回收率。这种基于 AgNPs/GO/SPCE 的新型传感器有望在各种环境和工业应用中灵敏可靠地检测双酚 A。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Analytical Chemistry
Journal of Analytical Chemistry 化学-分析化学
CiteScore
2.10
自引率
9.10%
发文量
146
审稿时长
13 months
期刊介绍: The Journal of Analytical Chemistry is an international peer reviewed journal that covers theoretical and applied aspects of analytical chemistry; it informs the reader about new achievements in analytical methods, instruments and reagents. Ample space is devoted to problems arising in the analysis of vital media such as water and air. Consideration is given to the detection and determination of metal ions, anions, and various organic substances. The journal welcomes manuscripts from all countries in the English or Russian language.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信