Impact of Tigecycline on Coagulation in Severe Infections and Effect of Vitamin K1 Intervention: A Retrospective Single-Center Analysis.

IF 3.1 4区 医学 Q1 Medicine
Haiyan Sun, Xianqing Meng, Xupeng Shao, Liyun Duan, Kailiang Fan
{"title":"Impact of Tigecycline on Coagulation in Severe Infections and Effect of Vitamin K1 Intervention: A Retrospective Single-Center Analysis.","authors":"Haiyan Sun, Xianqing Meng, Xupeng Shao, Liyun Duan, Kailiang Fan","doi":"10.12659/MSM.944778","DOIUrl":null,"url":null,"abstract":"<p><p>BACKGROUND Tigecycline is a tetracycline antibiotic used to treat gram-positive and gram-negative bacterial infections, and bleeding is a dose-dependent adverse effect. Vitamin K1 is a fat-soluble vitamin used to treat hemorrhagic conditions. This retrospective study from a single center included 920 patients treated with tigecycline for bacterial infections between January 2017 and December 2022 and aimed to evaluate the incidence of coagulopathy and the use of vitamin K1. MATERIAL AND METHODS A total of 220 patients were included and divided into a high-dose group (100 mg, every 12 h) and normal-dose group (50 mg, every 12 h) according to the treatment dose of tigecycline. Clinical characteristics and changes in coagulation indicators during tigecycline treatment were collected. Seventy-two patients were treated with vitamin K1, and the changes in coagulation indicators before and after treatment were compared. ANOVA and t test were used to analyze the effects of different doses of tigecycline on coagulation function and the intervention of vitamin K1. RESULTS Among 920 patients, the incidence of coagulopathy was 23.91%. In both groups, coagulopathy occurred on days 5 to 7 after administration, and the high-dose group had worse coagulation function than the normal-dose group, including activated partial thrombin time, prothrombin time, and fibrinogen (P<0.05). After treatment with vitamin K1, fibrinogen increased and activated partial thrombin time and prothrombin time were shortened in both groups (P<0.05 or P<0.01). CONCLUSIONS Tigecycline caused coagulopathy with dose and time dependence. Vitamin K1 can improve tigecycline-induced coagulopathy.</p>","PeriodicalId":48888,"journal":{"name":"Medical Science Monitor","volume":"30 ","pages":"e944778"},"PeriodicalIF":3.1000,"publicationDate":"2024-11-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11542504/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Science Monitor","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.12659/MSM.944778","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

BACKGROUND Tigecycline is a tetracycline antibiotic used to treat gram-positive and gram-negative bacterial infections, and bleeding is a dose-dependent adverse effect. Vitamin K1 is a fat-soluble vitamin used to treat hemorrhagic conditions. This retrospective study from a single center included 920 patients treated with tigecycline for bacterial infections between January 2017 and December 2022 and aimed to evaluate the incidence of coagulopathy and the use of vitamin K1. MATERIAL AND METHODS A total of 220 patients were included and divided into a high-dose group (100 mg, every 12 h) and normal-dose group (50 mg, every 12 h) according to the treatment dose of tigecycline. Clinical characteristics and changes in coagulation indicators during tigecycline treatment were collected. Seventy-two patients were treated with vitamin K1, and the changes in coagulation indicators before and after treatment were compared. ANOVA and t test were used to analyze the effects of different doses of tigecycline on coagulation function and the intervention of vitamin K1. RESULTS Among 920 patients, the incidence of coagulopathy was 23.91%. In both groups, coagulopathy occurred on days 5 to 7 after administration, and the high-dose group had worse coagulation function than the normal-dose group, including activated partial thrombin time, prothrombin time, and fibrinogen (P<0.05). After treatment with vitamin K1, fibrinogen increased and activated partial thrombin time and prothrombin time were shortened in both groups (P<0.05 or P<0.01). CONCLUSIONS Tigecycline caused coagulopathy with dose and time dependence. Vitamin K1 can improve tigecycline-induced coagulopathy.

替加环素对严重感染患者凝血功能的影响以及维生素 K1 干预的效果:单中心回顾性分析
背景 惕加环素是一种四环素类抗生素,用于治疗革兰氏阳性和革兰氏阴性细菌感染,出血是一种剂量依赖性不良反应。维生素 K1 是一种脂溶性维生素,用于治疗出血性疾病。这项来自单个中心的回顾性研究纳入了2017年1月至2022年12月期间使用替加环素治疗细菌感染的920例患者,旨在评估凝血病的发生率和维生素K1的使用情况。材料与方法 共纳入 220 例患者,根据替加环素的治疗剂量分为高剂量组(100 毫克,每 12 小时一次)和正常剂量组(50 毫克,每 12 小时一次)。收集替加环素治疗期间的临床特征和凝血指标变化。72 例患者接受了维生素 K1 治疗,并比较了治疗前后凝血指标的变化。采用方差分析和 t 检验分析不同剂量替加环素对凝血功能的影响以及维生素 K1 的干预作用。结果 920 例患者中,凝血功能障碍发生率为 23.91%。两组患者均在用药后第 5 至 7 天出现凝血功能障碍,且大剂量组的凝血功能(包括活化部分凝血酶时间、凝血酶原时间和纤维蛋白原)差于正常剂量组(P<0.05)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Medical Science Monitor
Medical Science Monitor MEDICINE, RESEARCH & EXPERIMENTAL-
CiteScore
6.40
自引率
3.20%
发文量
514
审稿时长
3.0 months
期刊介绍: Medical Science Monitor (MSM) established in 1995 is an international, peer-reviewed scientific journal which publishes original articles in Clinical Medicine and related disciplines such as Epidemiology and Population Studies, Product Investigations, Development of Laboratory Techniques :: Diagnostics and Medical Technology which enable presentation of research or review works in overlapping areas of medicine and technology such us (but not limited to): medical diagnostics, medical imaging systems, computer simulation of health and disease processes, new medical devices, etc. Reviews and Special Reports - papers may be accepted on the basis that they provide a systematic, critical and up-to-date overview of literature pertaining to research or clinical topics. Meta-analyses are considered as reviews. A special attention will be paid to a teaching value of a review paper. Medical Science Monitor is internationally indexed in Thomson-Reuters Web of Science, Journals Citation Report (JCR), Science Citation Index Expanded (SCI), Index Medicus MEDLINE, PubMed, PMC, EMBASE/Excerpta Medica, Chemical Abstracts CAS and Index Copernicus.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信