Safety and Efficacy of Lumen-Apposing Metal Stents for Management of Late Refractory Gastro-jejunal Structures in Patients with Roux-en-Y Gastric Bypass (with Video).
Rohit Agrawal, Soban Maan, Alejandra Méndez, Mouaz Haffar, Ethan M Cohen, Ayowumi A Adekolu, Matthew Krafft, Shyam Thakkar, Shailendra Singh
{"title":"Safety and Efficacy of Lumen-Apposing Metal Stents for Management of Late Refractory Gastro-jejunal Structures in Patients with Roux-en-Y Gastric Bypass (with Video).","authors":"Rohit Agrawal, Soban Maan, Alejandra Méndez, Mouaz Haffar, Ethan M Cohen, Ayowumi A Adekolu, Matthew Krafft, Shyam Thakkar, Shailendra Singh","doi":"10.1007/s10620-024-08707-z","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Roux-en-Y gastric bypass (RYGB) related late gastro-jejunal (GJ) strictures are often resistant to endoscopic balloon dilations. Lumen-apposing metal stents (LAMSs) have been used to treat benign strictures with favorable results. However, the data remains limited to justify LAMS use for management of post-RYGB late GJ strictures. We aim to evaluate the safety and efficacy of LAMS placement for the management of late GJ strictures that are refractory to balloon dilations in post-RYGB patients.</p><p><strong>Methods: </strong>This was a single center retrospective study that included all post-RYGB patients who underwent LAMS placement for management of late GJ strictures that had previously failed balloon dilations. Primary outcomes were technical and clinical success, and secondary outcomes were LAMS-related adverse events.</p><p><strong>Results: </strong>A total of 28 patients underwent LAMS placement for management of GJ strictures. Median age was 60.5 (IQR 50.5, 67.0) years and majority were females (27, 96.4%). Median interval between surgery and first diagnosis of GJ stricture was 13 years (IQR 7, 17.5). 20 × 10 mm LAMS was the most used stent (n = 24, 85.7%). The median procedure time was 23.5 (IQR 14.5, 32.0) minutes. Technical and short-term clinical success of LAMS placement was 100% (95% CI 87.9-100.0). Long-term success was achieved in 19 out of 25 patients (76.0%, 95% CI 56.6-88.5) that had over 3 months follow-up after LAMS removal. Stent migration was noted in 2 (7.1%) patients, and 1 (3.6%) patient each experienced pain and minor bleeding without the need for additional interventions. No patient in our cohort required surgical revision of GJ anastomosis.</p><p><strong>Conclusion: </strong>Placement of LAMS is safe, technically feasible, and associated with a high clinical success rate in patients with late GJ strictures after RYGB who have failed prior balloon dilations. Placement of LAMS can be considered early in patients requiring multiple balloon dilations.</p>","PeriodicalId":11378,"journal":{"name":"Digestive Diseases and Sciences","volume":" ","pages":""},"PeriodicalIF":2.5000,"publicationDate":"2024-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digestive Diseases and Sciences","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10620-024-08707-z","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: Roux-en-Y gastric bypass (RYGB) related late gastro-jejunal (GJ) strictures are often resistant to endoscopic balloon dilations. Lumen-apposing metal stents (LAMSs) have been used to treat benign strictures with favorable results. However, the data remains limited to justify LAMS use for management of post-RYGB late GJ strictures. We aim to evaluate the safety and efficacy of LAMS placement for the management of late GJ strictures that are refractory to balloon dilations in post-RYGB patients.
Methods: This was a single center retrospective study that included all post-RYGB patients who underwent LAMS placement for management of late GJ strictures that had previously failed balloon dilations. Primary outcomes were technical and clinical success, and secondary outcomes were LAMS-related adverse events.
Results: A total of 28 patients underwent LAMS placement for management of GJ strictures. Median age was 60.5 (IQR 50.5, 67.0) years and majority were females (27, 96.4%). Median interval between surgery and first diagnosis of GJ stricture was 13 years (IQR 7, 17.5). 20 × 10 mm LAMS was the most used stent (n = 24, 85.7%). The median procedure time was 23.5 (IQR 14.5, 32.0) minutes. Technical and short-term clinical success of LAMS placement was 100% (95% CI 87.9-100.0). Long-term success was achieved in 19 out of 25 patients (76.0%, 95% CI 56.6-88.5) that had over 3 months follow-up after LAMS removal. Stent migration was noted in 2 (7.1%) patients, and 1 (3.6%) patient each experienced pain and minor bleeding without the need for additional interventions. No patient in our cohort required surgical revision of GJ anastomosis.
Conclusion: Placement of LAMS is safe, technically feasible, and associated with a high clinical success rate in patients with late GJ strictures after RYGB who have failed prior balloon dilations. Placement of LAMS can be considered early in patients requiring multiple balloon dilations.
期刊介绍:
Digestive Diseases and Sciences publishes high-quality, peer-reviewed, original papers addressing aspects of basic/translational and clinical research in gastroenterology, hepatology, and related fields. This well-illustrated journal features comprehensive coverage of basic pathophysiology, new technological advances, and clinical breakthroughs; insights from prominent academicians and practitioners concerning new scientific developments and practical medical issues; and discussions focusing on the latest changes in local and worldwide social, economic, and governmental policies that affect the delivery of care within the disciplines of gastroenterology and hepatology.