Rapid detection of human adenovirus by multiple cross displacement amplification combined with nanoparticle-based biosensor platform

IF 6.5 Q1 BIOTECHNOLOGY & APPLIED MICROBIOLOGY
Linglong Wan , Xiaolan Huang , Jin Fu , Fei Xiao , Nan Jia , Yu Zhang , Min Chen , Xiong Zhu , Shijun Li , Juan Zhou , Yi Wang
{"title":"Rapid detection of human adenovirus by multiple cross displacement amplification combined with nanoparticle-based biosensor platform","authors":"Linglong Wan ,&nbsp;Xiaolan Huang ,&nbsp;Jin Fu ,&nbsp;Fei Xiao ,&nbsp;Nan Jia ,&nbsp;Yu Zhang ,&nbsp;Min Chen ,&nbsp;Xiong Zhu ,&nbsp;Shijun Li ,&nbsp;Juan Zhou ,&nbsp;Yi Wang","doi":"10.1016/j.snr.2024.100252","DOIUrl":null,"url":null,"abstract":"<div><div>Human adenoviruses (HAdV), particularly serotypes 3 and 7 (HAdV-3 and HAdV-7), are significant respiratory pathogens that contribute to high morbidity rates and severe pneumonia in infants and children. The lack of distinct clinical presentations and effective treatments highlights the urgent need for rapid and reliable diagnostic methods for HAdV-3 and HAdV-7. This study devises a novel detection assay, termed HAdV-MCDA-LFB, which combines isothermal multiple cross displacement amplification (MCDA) with a nanoparticle-based lateral flow biosensor (LFB). Targeting the conserved hexon gene, HAdV-MCDA-LFB demonstrated high sensitivity, detecting low to 10 fg of hexon-containing plasmid per reaction without cross-reaction under the optimized conditions. Moreover, HAdV-MCDA-LFB exhibited comparable diagnostic accuracy to real-time PCR in clinical sample analysis, indicating its practical applicability. The whole procedure, including rapid template preparation (15 min), MCDA reaction (40 min at 67 °C) and result interpretation (&lt;5 min), can be completed within one hour. Together, this rapid turnaround time, coupled with its simplicity and accuracy, makes HAdV-MCDA-LFB a promising point-of-care diagnostic tool for HAdV-3 and HAdV-7, particularly in resource-limited settings.</div></div>","PeriodicalId":426,"journal":{"name":"Sensors and Actuators Reports","volume":"8 ","pages":"Article 100252"},"PeriodicalIF":6.5000,"publicationDate":"2024-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors and Actuators Reports","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666053924000687","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOTECHNOLOGY & APPLIED MICROBIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Human adenoviruses (HAdV), particularly serotypes 3 and 7 (HAdV-3 and HAdV-7), are significant respiratory pathogens that contribute to high morbidity rates and severe pneumonia in infants and children. The lack of distinct clinical presentations and effective treatments highlights the urgent need for rapid and reliable diagnostic methods for HAdV-3 and HAdV-7. This study devises a novel detection assay, termed HAdV-MCDA-LFB, which combines isothermal multiple cross displacement amplification (MCDA) with a nanoparticle-based lateral flow biosensor (LFB). Targeting the conserved hexon gene, HAdV-MCDA-LFB demonstrated high sensitivity, detecting low to 10 fg of hexon-containing plasmid per reaction without cross-reaction under the optimized conditions. Moreover, HAdV-MCDA-LFB exhibited comparable diagnostic accuracy to real-time PCR in clinical sample analysis, indicating its practical applicability. The whole procedure, including rapid template preparation (15 min), MCDA reaction (40 min at 67 °C) and result interpretation (<5 min), can be completed within one hour. Together, this rapid turnaround time, coupled with its simplicity and accuracy, makes HAdV-MCDA-LFB a promising point-of-care diagnostic tool for HAdV-3 and HAdV-7, particularly in resource-limited settings.

Abstract Image

通过多重交叉置换扩增结合纳米粒子生物传感器平台快速检测人类腺病毒
人类腺病毒(HAdV),尤其是血清型 3 和 7(HAdV-3 和 HAdV-7),是导致婴幼儿高发病率和严重肺炎的重要呼吸道病原体。由于缺乏独特的临床表现和有效的治疗方法,因此迫切需要快速可靠的 HAdV-3 和 HAdV-7 诊断方法。本研究设计了一种新型检测方法,称为 HAdV-MCDA-LFB,它将等温多重交叉位移扩增(MCDA)与基于纳米粒子的侧流生物传感器(LFB)相结合。针对保守的 hexon 基因,HAdV-MCDA-LFB 表现出极高的灵敏度,在优化条件下,每次反应可检测低至 10 fg 的含 hexon 质粒,且无交叉反应。此外,在临床样本分析中,HAdV-MCDA-LFB 的诊断准确性可与实时 PCR 相媲美,这表明它具有实用性。整个过程包括快速模板制备(15 分钟)、MCDA 反应(40 分钟,67 ℃)和结果判读(5 分钟),可在一小时内完成。这种快速的周转时间,再加上其简便性和准确性,使 HAdV-MCDA-LFB 成为一种很有前途的 HAdV-3 和 HAdV-7 床旁诊断工具,尤其是在资源有限的环境中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
9.60
自引率
0.00%
发文量
60
审稿时长
49 days
期刊介绍: Sensors and Actuators Reports is a peer-reviewed open access journal launched out from the Sensors and Actuators journal family. Sensors and Actuators Reports is dedicated to publishing new and original works in the field of all type of sensors and actuators, including bio-, chemical-, physical-, and nano- sensors and actuators, which demonstrates significant progress beyond the current state of the art. The journal regularly publishes original research papers, reviews, and short communications. For research papers and short communications, the journal aims to publish the new and original work supported by experimental results and as such purely theoretical works are not accepted.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信