New solid phase microextraction fibers with green clay coating via radio frequency magnetron sputtering for detecting low-polar compounds in water samples
Jhon Fiscal-Ladino , Juan Jose Lozada-Castro , Jhon Jairo Rios-Acevedo , Diego Montaño-Montoya , Eduardo Carasek , Pablo Richter , Alvaro Pulzara-Mora , Liliana Moncayo Martínez , Milton Rosero-Moreano
{"title":"New solid phase microextraction fibers with green clay coating via radio frequency magnetron sputtering for detecting low-polar compounds in water samples","authors":"Jhon Fiscal-Ladino , Juan Jose Lozada-Castro , Jhon Jairo Rios-Acevedo , Diego Montaño-Montoya , Eduardo Carasek , Pablo Richter , Alvaro Pulzara-Mora , Liliana Moncayo Martínez , Milton Rosero-Moreano","doi":"10.1016/j.aca.2024.343375","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Developing highly sensitive and selective measurement techniques to detect trace compounds in diverse matrices is a significant challenge in analytical chemistry. These techniques must adhere to green chemistry principles by minimizing organic solvent use, simplifying sample preparation, and streamlining process steps. Additionally, there is a growing need for sustainable analytical methods due to increased environmental awareness. The problem addressed in this work is the need for an eco-friendly and efficient method for the extraction and detection of trace organochlorine pesticides in water samples.</div></div><div><h3>Results</h3><div>We employed SPME using a novel clay thin film sorbent, deposited on a nickel-titanium alloy wire via magnetron sputtering. Montmorillonite clay was chosen for its excellent adsorption properties and eco-friendly nature, aligning with green chemistry principles. The approach involved coating the SPME fiber with hydrophobic modified montmorillonite clay, followed by silylation. The method was tested for extracting 12 model organochlorine pesticides, including BHC, lindane, and DDT, demonstrating high isolation efficiency. The coated thin film and its silylation modification were characterized using standard spectroscopic techniques, confirming the successful creation of a new adsorbent phase. The direct immersion SPME approach achieved relative recoveries ranging from 65 % to 99 %, with reproducibility (RSD) below 6 %. This method provided low detection limits (10–15 ng L<sup>−1</sup>) and quantitation limits (32–50 ng L<sup>−1</sup>).</div></div><div><h3>Significance</h3><div>Our approach offers an eco-friendly, highly efficient solution for the extraction and detection of trace organochlorine pesticides. The significant improvement in recovery rates and reproducibility, combined with low detection and quantitation limits, underscores the potential of this method to enhance analytical practices in environmental monitoring and public health. Furthermore, the use of sustainable materials and processes aligns with global efforts to reduce environmental impact in analytical chemistry.</div></div>","PeriodicalId":240,"journal":{"name":"Analytica Chimica Acta","volume":"1332 ","pages":"Article 343375"},"PeriodicalIF":5.7000,"publicationDate":"2024-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytica Chimica Acta","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0003267024011760","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Background
Developing highly sensitive and selective measurement techniques to detect trace compounds in diverse matrices is a significant challenge in analytical chemistry. These techniques must adhere to green chemistry principles by minimizing organic solvent use, simplifying sample preparation, and streamlining process steps. Additionally, there is a growing need for sustainable analytical methods due to increased environmental awareness. The problem addressed in this work is the need for an eco-friendly and efficient method for the extraction and detection of trace organochlorine pesticides in water samples.
Results
We employed SPME using a novel clay thin film sorbent, deposited on a nickel-titanium alloy wire via magnetron sputtering. Montmorillonite clay was chosen for its excellent adsorption properties and eco-friendly nature, aligning with green chemistry principles. The approach involved coating the SPME fiber with hydrophobic modified montmorillonite clay, followed by silylation. The method was tested for extracting 12 model organochlorine pesticides, including BHC, lindane, and DDT, demonstrating high isolation efficiency. The coated thin film and its silylation modification were characterized using standard spectroscopic techniques, confirming the successful creation of a new adsorbent phase. The direct immersion SPME approach achieved relative recoveries ranging from 65 % to 99 %, with reproducibility (RSD) below 6 %. This method provided low detection limits (10–15 ng L−1) and quantitation limits (32–50 ng L−1).
Significance
Our approach offers an eco-friendly, highly efficient solution for the extraction and detection of trace organochlorine pesticides. The significant improvement in recovery rates and reproducibility, combined with low detection and quantitation limits, underscores the potential of this method to enhance analytical practices in environmental monitoring and public health. Furthermore, the use of sustainable materials and processes aligns with global efforts to reduce environmental impact in analytical chemistry.
期刊介绍:
Analytica Chimica Acta has an open access mirror journal Analytica Chimica Acta: X, sharing the same aims and scope, editorial team, submission system and rigorous peer review.
Analytica Chimica Acta provides a forum for the rapid publication of original research, and critical, comprehensive reviews dealing with all aspects of fundamental and applied modern analytical chemistry. The journal welcomes the submission of research papers which report studies concerning the development of new and significant analytical methodologies. In determining the suitability of submitted articles for publication, particular scrutiny will be placed on the degree of novelty and impact of the research and the extent to which it adds to the existing body of knowledge in analytical chemistry.