{"title":"C1q-Fixing De Novo Donor Specific Antibodies in Therapeutic Management of Chronic Antibody-Mediated Rejection Postkidney Transplantation","authors":"Masayuki Tasaki, Kazuhide Saito, Masahiro Ikeda, Yoshihiko Tomita","doi":"10.1016/j.transproceed.2024.10.022","DOIUrl":null,"url":null,"abstract":"<div><h3>Backgrounds</h3><div>Evidence for C1q-fixing donor-specific antibodies (DSA) after chronic antibody-mediated rejection (CABMR) treatment is lacking. We investigated if C1q-DSA could predict therapy response in patients with biopsy-proven CABMR.</div></div><div><h3>Material and Methods</h3><div>Twenty kidney transplant patients with late-onset DSA were enrolled. Patients with biopsy-proven CABMR received three plasma pheresis sessions, one dose of rituximab (375 mg/m<sup>2</sup>), and steroid pulse therapy. We monitored IgG-DSA, C1q-DSA, and renal graft function for >2 years post-CABMR treatment. Patients with C1q-DSA mean fluorescence intensity (MFI) decreased by less than 50% post-treatment were classified as C1q-nonresponders. We compared Banff classification scores (g, ptc, cg, c4d) before and 6 months after treatment.</div></div><div><h3>Results</h3><div>Fourteen (70%) of 20 patients were C1q-DSA positive. The MFIs of IgG-DSA and C1q-DSA before treatment were significantly higher in the C1q-DSA positive group than in the negative group, at 20,035 and 10,918 (<em>P</em> = .008) and 17,702 and 21 (<em>P</em> < .001), respectively. Fifteen patients (75%) were diagnosed with CABMR via biopsy, and 12 patients received rejection therapy. Five (41.7%) patients were C1q-responders and seven (58.3%) were C1q-nonresponders. The MFIs of C1q-DSA before treatment were not significantly different between the two groups (11,521 vs. 13,985). Renal graft function was stable after treatment in C1q-responders for 3 years. In contrast, renal graft function tended to deteriorate in C1q-nonresponders. Biopsy showed improvement in scores in 75% of C1q-responders while deterioration in scores in 42.9% of C1q-nonresponders.</div></div><div><h3>Conclusions</h3><div>C1q-DSA may be a good predictor of outcomes after CABMR treatment.</div></div>","PeriodicalId":23246,"journal":{"name":"Transplantation proceedings","volume":"56 9","pages":"Pages 1961-1966"},"PeriodicalIF":0.8000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transplantation proceedings","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0041134524005347","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"IMMUNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Backgrounds
Evidence for C1q-fixing donor-specific antibodies (DSA) after chronic antibody-mediated rejection (CABMR) treatment is lacking. We investigated if C1q-DSA could predict therapy response in patients with biopsy-proven CABMR.
Material and Methods
Twenty kidney transplant patients with late-onset DSA were enrolled. Patients with biopsy-proven CABMR received three plasma pheresis sessions, one dose of rituximab (375 mg/m2), and steroid pulse therapy. We monitored IgG-DSA, C1q-DSA, and renal graft function for >2 years post-CABMR treatment. Patients with C1q-DSA mean fluorescence intensity (MFI) decreased by less than 50% post-treatment were classified as C1q-nonresponders. We compared Banff classification scores (g, ptc, cg, c4d) before and 6 months after treatment.
Results
Fourteen (70%) of 20 patients were C1q-DSA positive. The MFIs of IgG-DSA and C1q-DSA before treatment were significantly higher in the C1q-DSA positive group than in the negative group, at 20,035 and 10,918 (P = .008) and 17,702 and 21 (P < .001), respectively. Fifteen patients (75%) were diagnosed with CABMR via biopsy, and 12 patients received rejection therapy. Five (41.7%) patients were C1q-responders and seven (58.3%) were C1q-nonresponders. The MFIs of C1q-DSA before treatment were not significantly different between the two groups (11,521 vs. 13,985). Renal graft function was stable after treatment in C1q-responders for 3 years. In contrast, renal graft function tended to deteriorate in C1q-nonresponders. Biopsy showed improvement in scores in 75% of C1q-responders while deterioration in scores in 42.9% of C1q-nonresponders.
Conclusions
C1q-DSA may be a good predictor of outcomes after CABMR treatment.
期刊介绍:
Transplantation Proceedings publishes several different categories of manuscripts, all of which undergo extensive peer review by recognized authorities in the field prior to their acceptance for publication.
The first type of manuscripts consists of sets of papers providing an in-depth expression of the current state of the art in various rapidly developing components of world transplantation biology and medicine. These manuscripts emanate from congresses of the affiliated transplantation societies, from Symposia sponsored by the Societies, as well as special Conferences and Workshops covering related topics.
Transplantation Proceedings also publishes several special sections including publication of Clinical Transplantation Proceedings, being rapid original contributions of preclinical and clinical experiences. These manuscripts undergo review by members of the Editorial Board.
Original basic or clinical science articles, clinical trials and case studies can be submitted to the journal?s open access companion title Transplantation Reports.