{"title":"Selection of Force Sensors for <i>In Situ</i> Measurement of Neotissue Microenvironments.","authors":"Marta Rodriguez Navas, Eric M Darling","doi":"10.1089/ten.tea.2024.0192","DOIUrl":null,"url":null,"abstract":"<p><p>Mechanical forces are a critical stimulus in both native and engineered tissues. Direct measurement of these microenvironmental forces has been challenging, particularly for cell-dense models. To address this, we previously developed hydrogel-based force sensors that are approximately the size of a cell and can be imaged over time to computationally assess the forces exerted by surrounding cells and matrix. The goal of this project was to identify how the physical characteristics of force sensors impact measurements. Sensors were varied in size, elastic modulus, and surface coating before being included in stem cell suspensions that then spontaneously self-assembled into spheroidal neotissues. Using this model of early mesenchymal condensation, we hypothesized that larger, softer sensors would provide greater sensitivity and precision, whereas protein coatings would influence the directionality of applied forces (tensile vs. compressive). These experiments were conducted using a high-content imaging system that allowed analysis of over a thousand sensors to evaluate the various conditions. Results indicated that measurement fidelity was highest for force sensors that had a diameter >20 µm and modulus ∼0.2 kPa. Extremely soft sensors deformed too much, whereas stiffer sensors deformed too little. Collagen and N-cadherin coatings, which replicated cell-matrix or cell-cell binding, respectively, allowed for tensile forces to be exerted on the sensors, with greater forces being observed for N-cadherin sensors in these highly cellular neotissue constructs. Uncoated sensors were universally compressed due to the lack of cell-sensor adhesion. Disruption of the actin cytoskeleton lessened microenvironmental forces, whereas disruption of microtubules had no measurable effect. Potential future applications of the technology include studies of <i>in situ</i> forces in developing tissues as well as a real-time sensor for monitoring the growth of engineered constructs.</p>","PeriodicalId":56375,"journal":{"name":"Tissue Engineering Part A","volume":" ","pages":""},"PeriodicalIF":3.5000,"publicationDate":"2024-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Tissue Engineering Part A","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1089/ten.tea.2024.0192","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CELL & TISSUE ENGINEERING","Score":null,"Total":0}
引用次数: 0
Abstract
Mechanical forces are a critical stimulus in both native and engineered tissues. Direct measurement of these microenvironmental forces has been challenging, particularly for cell-dense models. To address this, we previously developed hydrogel-based force sensors that are approximately the size of a cell and can be imaged over time to computationally assess the forces exerted by surrounding cells and matrix. The goal of this project was to identify how the physical characteristics of force sensors impact measurements. Sensors were varied in size, elastic modulus, and surface coating before being included in stem cell suspensions that then spontaneously self-assembled into spheroidal neotissues. Using this model of early mesenchymal condensation, we hypothesized that larger, softer sensors would provide greater sensitivity and precision, whereas protein coatings would influence the directionality of applied forces (tensile vs. compressive). These experiments were conducted using a high-content imaging system that allowed analysis of over a thousand sensors to evaluate the various conditions. Results indicated that measurement fidelity was highest for force sensors that had a diameter >20 µm and modulus ∼0.2 kPa. Extremely soft sensors deformed too much, whereas stiffer sensors deformed too little. Collagen and N-cadherin coatings, which replicated cell-matrix or cell-cell binding, respectively, allowed for tensile forces to be exerted on the sensors, with greater forces being observed for N-cadherin sensors in these highly cellular neotissue constructs. Uncoated sensors were universally compressed due to the lack of cell-sensor adhesion. Disruption of the actin cytoskeleton lessened microenvironmental forces, whereas disruption of microtubules had no measurable effect. Potential future applications of the technology include studies of in situ forces in developing tissues as well as a real-time sensor for monitoring the growth of engineered constructs.
期刊介绍:
Tissue Engineering is the preeminent, biomedical journal advancing the field with cutting-edge research and applications that repair or regenerate portions or whole tissues. This multidisciplinary journal brings together the principles of engineering and life sciences in the creation of artificial tissues and regenerative medicine. Tissue Engineering is divided into three parts, providing a central forum for groundbreaking scientific research and developments of clinical applications from leading experts in the field that will enable the functional replacement of tissues.