Cardiac troponin I release after transcatheter closure of atrial septal defects is associated with supraventricular arrhythmias on early follow-up.

IF 1.5 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Postepy W Kardiologii Interwencyjnej Pub Date : 2024-09-01 Epub Date: 2024-08-14 DOI:10.5114/aic.2024.142326
Paweł Prochownik, Klaudia Bielecka, Tadeusz Przewłocki, Zuzanna Sachajko, Urszula Gancarczyk, Piotr Wilkołek, Michał Tworek, Piotr Podolec, Larysa Bielecka, Monika Komar
{"title":"Cardiac troponin I release after transcatheter closure of atrial septal defects is associated with supraventricular arrhythmias on early follow-up.","authors":"Paweł Prochownik, Klaudia Bielecka, Tadeusz Przewłocki, Zuzanna Sachajko, Urszula Gancarczyk, Piotr Wilkołek, Michał Tworek, Piotr Podolec, Larysa Bielecka, Monika Komar","doi":"10.5114/aic.2024.142326","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Atrial septal defects (ASD) are prevalent congenital heart anomalies found in the adult population. Percutaneous ASD closure has become a routine clinical practice. Elevation of postprocedural transient cardiac biomarkers and exacerbation of supraventricular arrhythmias have been reported in the subject literature.</p><p><strong>Aim: </strong>To explore the relationship between cardiac troponin I (cTnI) elevation and supraventricular ectopy (SVE) following percutaneous closure of secundum atrial septal defect (ASD) in adult patients.</p><p><strong>Material and methods: </strong>600 consecutive patients who underwent successful transcatheter ASD secundum closure were analyzed. Serum levels of cTnI were measured before and within 72 h of device implantation. 24-hour Holter monitoring was performed before the procedure, at 1 month, and at 6 months of follow-up.</p><p><strong>Results: </strong>SVE burden increased 1 month after the procedure (median 1021.00; min.-max. 11.00-29 862.00) compared to baseline values (median 146.00; min.-max. 0-1865.00; <i>p</i> < 0.01). 61.7% of patients demonstrated a cTnI rise exceeding 50% of the upper reference limit within 24 h of the procedure. A statistically significant positive correlation between SVE burden 1 month after the procedure and periprocedural cTnI increase (<i>p</i> < 0.05, <i>r</i> = 0.41) was observed, while cTnI levels significantly correlated with procedure and fluoroscopy time (<i>p</i> < 0.001), device size (<i>p</i> < 0.001) and maximal ASD diameter (<i>p</i> < 0.001).</p><p><strong>Conclusions: </strong>A significant increase of cTnI is noted frequently after transcatheter ASD closure and seems to predict exacerbation in SVE burden on short-term follow up. The independent risk factors of cTnI rise are prolonged procedure duration and larger device sizes.</p>","PeriodicalId":49678,"journal":{"name":"Postepy W Kardiologii Interwencyjnej","volume":"20 3","pages":"338-344"},"PeriodicalIF":1.5000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11506394/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Postepy W Kardiologii Interwencyjnej","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5114/aic.2024.142326","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/14 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Atrial septal defects (ASD) are prevalent congenital heart anomalies found in the adult population. Percutaneous ASD closure has become a routine clinical practice. Elevation of postprocedural transient cardiac biomarkers and exacerbation of supraventricular arrhythmias have been reported in the subject literature.

Aim: To explore the relationship between cardiac troponin I (cTnI) elevation and supraventricular ectopy (SVE) following percutaneous closure of secundum atrial septal defect (ASD) in adult patients.

Material and methods: 600 consecutive patients who underwent successful transcatheter ASD secundum closure were analyzed. Serum levels of cTnI were measured before and within 72 h of device implantation. 24-hour Holter monitoring was performed before the procedure, at 1 month, and at 6 months of follow-up.

Results: SVE burden increased 1 month after the procedure (median 1021.00; min.-max. 11.00-29 862.00) compared to baseline values (median 146.00; min.-max. 0-1865.00; p < 0.01). 61.7% of patients demonstrated a cTnI rise exceeding 50% of the upper reference limit within 24 h of the procedure. A statistically significant positive correlation between SVE burden 1 month after the procedure and periprocedural cTnI increase (p < 0.05, r = 0.41) was observed, while cTnI levels significantly correlated with procedure and fluoroscopy time (p < 0.001), device size (p < 0.001) and maximal ASD diameter (p < 0.001).

Conclusions: A significant increase of cTnI is noted frequently after transcatheter ASD closure and seems to predict exacerbation in SVE burden on short-term follow up. The independent risk factors of cTnI rise are prolonged procedure duration and larger device sizes.

经导管封堵房间隔缺损后的心肌肌钙蛋白 I 释放与早期随访的室上性心律失常有关。
导言:房间隔缺损(ASD)是成年人群中常见的先天性心脏畸形。经皮房间隔缺损(ASD)封堵术已成为常规临床实践。目的:探讨成年患者经皮关闭房间隔缺损(ASD)后心肌肌钙蛋白 I(cTnI)升高与室上性心律失常(SVE)之间的关系。材料与方法:分析了 600 例连续接受成功经导管ASD房间隔缺损关闭术的患者。在设备植入前和植入后 72 小时内测量血清 cTnI 水平。术前、术后 1 个月和随访 6 个月时进行 24 小时 Holter 监测:结果:与基线值(中位数 146.00;最小值-最大值 0-1865.00;p <0.01)相比,术后 1 个月 SVE 负荷增加(中位数 1021.00;最小值-最大值 11.00-29 862.00)。61.7%的患者在手术后 24 小时内 cTnI 升幅超过参考上限的 50%。术后1个月的SVE负荷与围手术期cTnI升高之间存在统计学意义上的正相关(p < 0.05,r = 0.41),而cTnI水平与手术和透视时间(p < 0.001)、设备大小(p < 0.001)和ASD最大直径(p < 0.001)显著相关:结论:经导管ASD闭合术后,cTnI经常出现明显升高,似乎可预测短期随访中SVE负担的加重。cTnI 升高的独立风险因素是手术时间延长和设备尺寸增大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Postepy W Kardiologii Interwencyjnej
Postepy W Kardiologii Interwencyjnej 医学-心血管系统
CiteScore
1.60
自引率
15.40%
发文量
36
审稿时长
6-12 weeks
期刊介绍: Postępy w Kardiologii Interwencyjnej/Advances in Interventional Cardiology is indexed in: Index Copernicus, Ministry of Science and Higher Education Index (MNiSW). Advances in Interventional Cardiology is a quarterly aimed at specialists, mainly at cardiologists and cardiosurgeons. Official journal of the Association on Cardiovascular Interventions of the Polish Cardiac Society.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信