Immediate implant placement in the premolar maxillary area: a cone-beam computed tomography study.

IF 2.2 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Ali Najm, Amer Bihorac, Vinícius de Carvalho Machado, Bruno Ramos Chrcanovic
{"title":"Immediate implant placement in the premolar maxillary area: a cone-beam computed tomography study.","authors":"Ali Najm, Amer Bihorac, Vinícius de Carvalho Machado, Bruno Ramos Chrcanovic","doi":"10.5051/jpis.2303580179","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This research aimed to investigate potential factors associated with the risk of perforation of the labial bone plate, nasal floor, or maxillary sinus floor during immediate implant placement (IIP) in the maxillary premolar area, utilizing a cone-beam computed tomography (CBCT) virtual study.</p><p><strong>Methods: </strong>CBCT exams from 179 eligible participants, encompassing 716 teeth, were included. Implants were virtually positioned in 2 orientations: along the long axis of the tooth (the prosthetically-driven position) and in an optimal position relative to adjacent anatomical structures (the bone-driven position). Binary logistic regression analysis was employed to assess potential associations between perforation or invasion and various covariates, including sex, age, tooth region, the distance from the tooth apex to the nasal floor or maxillary sinus floor, the angle between the prosthetically- and bone-driven positions (implant-line A angle [ILAA]), and the labial concavity angle (LCA).</p><p><strong>Results: </strong>The mean ILAA was 18.3°±8.0°, and the angle was significantly larger for the second premolar compared to the first premolar. The mean minimum implant length was 13.0±2.1 mm, with a bone anchorage of 4 mm. The incidence of perforation was 84.1% for the prosthetically-driven position and 40.5% for the bone-driven position. Factors associated with a higher risk of cortical bone wall perforation or invasion of the 2-mm safety margin from surrounding anatomical structures (in the bone-driven position) included female sex, older age, shorter distance from the tooth apex to the nasal cavity/maxillary sinus, and smaller LCA.</p><p><strong>Conclusions: </strong>A high prevalence of cortical bone wall perforation or invasion of the 2-mm safety margin is anticipated when performing IIP in the maxillary premolar region.</p>","PeriodicalId":48795,"journal":{"name":"Journal of Periodontal and Implant Science","volume":" ","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2024-08-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Periodontal and Implant Science","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5051/jpis.2303580179","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This research aimed to investigate potential factors associated with the risk of perforation of the labial bone plate, nasal floor, or maxillary sinus floor during immediate implant placement (IIP) in the maxillary premolar area, utilizing a cone-beam computed tomography (CBCT) virtual study.

Methods: CBCT exams from 179 eligible participants, encompassing 716 teeth, were included. Implants were virtually positioned in 2 orientations: along the long axis of the tooth (the prosthetically-driven position) and in an optimal position relative to adjacent anatomical structures (the bone-driven position). Binary logistic regression analysis was employed to assess potential associations between perforation or invasion and various covariates, including sex, age, tooth region, the distance from the tooth apex to the nasal floor or maxillary sinus floor, the angle between the prosthetically- and bone-driven positions (implant-line A angle [ILAA]), and the labial concavity angle (LCA).

Results: The mean ILAA was 18.3°±8.0°, and the angle was significantly larger for the second premolar compared to the first premolar. The mean minimum implant length was 13.0±2.1 mm, with a bone anchorage of 4 mm. The incidence of perforation was 84.1% for the prosthetically-driven position and 40.5% for the bone-driven position. Factors associated with a higher risk of cortical bone wall perforation or invasion of the 2-mm safety margin from surrounding anatomical structures (in the bone-driven position) included female sex, older age, shorter distance from the tooth apex to the nasal cavity/maxillary sinus, and smaller LCA.

Conclusions: A high prevalence of cortical bone wall perforation or invasion of the 2-mm safety margin is anticipated when performing IIP in the maxillary premolar region.

上颌前磨牙区即刻种植体植入:锥形束计算机断层扫描研究。
目的:本研究旨在利用锥束计算机断层扫描(CBCT)虚拟研究,调查上颌前磨牙区即刻种植体植入(IIP)过程中唇骨板、鼻底或上颌窦底穿孔风险的潜在相关因素:方法:共纳入 179 名符合条件的参与者的 CBCT 检查结果,包括 716 颗牙齿。种植体被虚拟定位在两个方向:沿牙齿长轴(修复驱动位置)和相对于邻近解剖结构的最佳位置(骨驱动位置)。采用二元逻辑回归分析评估穿孔或入侵与各种协变量(包括性别、年龄、牙区、牙顶到鼻底或上颌窦底的距离、修复体位置与骨驱动位置之间的角度(种植线 A 角 [ILAA])以及唇凹角 (LCA) )之间的潜在关联:平均 ILAA 为 18.3°±8.0°,第二前磨牙的角度明显大于第一前磨牙。种植体的平均最小长度为(13.0±2.1)毫米,骨锚定为 4 毫米。修复体驱动位置的穿孔发生率为 84.1%,骨驱动位置的穿孔发生率为 40.5%。与皮质骨壁穿孔或周围解剖结构侵入2毫米安全边缘(骨驱动位置)风险较高相关的因素包括女性、年龄较大、牙顶到鼻腔/上颌窦的距离较短以及LCA较小:结论:在上颌前磨牙区进行 IIP 时,预计皮质骨壁穿孔或侵入 2 毫米安全边缘的发生率较高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Periodontal and Implant Science
Journal of Periodontal and Implant Science DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.30
自引率
5.30%
发文量
38
期刊介绍: Journal of Periodontal & Implant Science (JPIS) is a peer-reviewed and open-access journal providing up-to-date information relevant to professionalism of periodontology and dental implantology. JPIS is dedicated to global and extensive publication which includes evidence-based original articles, and fundamental reviews in order to cover a variety of interests in the field of periodontal as well as implant science.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信