Qiya Gao, Jie Fu, Fangying Xiong, Jiawang Wang, Ziyue Qin, Shuang Li
{"title":"A Multi-Channel Urine Sensing Detection System Based on Creatinine, Uric Acid, and pH.","authors":"Qiya Gao, Jie Fu, Fangying Xiong, Jiawang Wang, Ziyue Qin, Shuang Li","doi":"10.3390/bios14100473","DOIUrl":null,"url":null,"abstract":"<p><p>Urine analysis represents a crucial diagnostic technique employed in clinical laboratories. Creatinine and uric acid in urine are essential biomarkers in the human body and are widely utilized in clinical analysis. Research has demonstrated a correlation between the normal physiological concentrations of creatinine and uric acid in urine and an increased risk of hypertension, cardiovascular diseases, and kidney disease. Furthermore, the pH of urine indicates the body's metabolic processes and homeostatic balance. In this study, an integrated multi-channel electrochemical sensing system was developed, combining electrochemical analysis techniques, microelectronic design, and nanomaterials. The architecture of an intelligent medical detection system and the production of an interactive interface for smartphones were accomplished. Initially, multi-channel selective electrodes were designed for creatinine, uric acid, and pH detection. The detection range was 10 nM to 100 μM for creatinine, 100 μM to 500 μM for uric acid, and 4 to 9 for pH. Furthermore, interference experiments were also conducted to verify the specificity of the sensors. Subsequently, multi-channel double-sided sensing electrodes and function-integrated hardware were designed, with the standard equations of target analytes stored in the system's read-only memory. Moreover, a WeChat mini-program platform was developed for smartphone interaction, enabling off-body detection and real-time display of target analytes through smartphones. Finally, the aforementioned electrochemical detection electrodes were integrated with the smart sensing system and wirelessly interfaced with smartphones, allowing for intelligent real-time detection in primary healthcare and individual household settings.</p>","PeriodicalId":48608,"journal":{"name":"Biosensors-Basel","volume":"14 10","pages":""},"PeriodicalIF":4.9000,"publicationDate":"2024-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11506577/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors-Basel","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/bios14100473","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Urine analysis represents a crucial diagnostic technique employed in clinical laboratories. Creatinine and uric acid in urine are essential biomarkers in the human body and are widely utilized in clinical analysis. Research has demonstrated a correlation between the normal physiological concentrations of creatinine and uric acid in urine and an increased risk of hypertension, cardiovascular diseases, and kidney disease. Furthermore, the pH of urine indicates the body's metabolic processes and homeostatic balance. In this study, an integrated multi-channel electrochemical sensing system was developed, combining electrochemical analysis techniques, microelectronic design, and nanomaterials. The architecture of an intelligent medical detection system and the production of an interactive interface for smartphones were accomplished. Initially, multi-channel selective electrodes were designed for creatinine, uric acid, and pH detection. The detection range was 10 nM to 100 μM for creatinine, 100 μM to 500 μM for uric acid, and 4 to 9 for pH. Furthermore, interference experiments were also conducted to verify the specificity of the sensors. Subsequently, multi-channel double-sided sensing electrodes and function-integrated hardware were designed, with the standard equations of target analytes stored in the system's read-only memory. Moreover, a WeChat mini-program platform was developed for smartphone interaction, enabling off-body detection and real-time display of target analytes through smartphones. Finally, the aforementioned electrochemical detection electrodes were integrated with the smart sensing system and wirelessly interfaced with smartphones, allowing for intelligent real-time detection in primary healthcare and individual household settings.
Biosensors-BaselBiochemistry, Genetics and Molecular Biology-Clinical Biochemistry
CiteScore
6.60
自引率
14.80%
发文量
983
审稿时长
11 weeks
期刊介绍:
Biosensors (ISSN 2079-6374) provides an advanced forum for studies related to the science and technology of biosensors and biosensing. It publishes original research papers, comprehensive reviews and communications. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. Electronic files and software regarding the full details of the calculation or experimental procedure, if unable to be published in a normal way, can be deposited as supplementary electronic material.