{"title":"High-Throughput Drug Stability Assessment via Biomimetic Metalloporphyrin-Catalyzed Reactions Using Laser-Assisted Rapid Evaporative Ionization Mass Spectrometry (LA-REIMS).","authors":"András Marton, Zsombor Mohácsi, Balázs Decsi, Balázs Csillag, Júlia Balog, Richard Schäffer, Tamás Karancsi, György Tibor Balogh","doi":"10.3390/pharmaceutics16101266","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> Building extensive drug candidate libraries as early in the development pipeline as possible, with high-throughput in vitro absorption, distribution, metabolism, and excretion (ADME) profiling, is crucial for the selection of lead compounds to guide subsequent research and production phases. Traditionally, the analysis of metabolic stability assays heavily relies on high-throughput LC-MS/MS (liquid chromatography tandem mass spectrometry) techniques to meet with the lead profiling demands. Laser-assisted rapid evaporative ionization mass spectrometry (LA-REIMS) is a quick and efficient technique for characterizing complex biological samples without laborious sample preparation. <b>Objective:</b> In this study, using an automated LA-REIMS well plate reader, achieving an 8 s per sample measurement time, the oxidative metabolic stability of active drug agents was assessed using biomimetic metalloporphyrin-based oxidative model reactions. <b>Results:</b> The results obtained using the novel LA-REIMS-based protocol were compared to and corroborated by those obtained using conventional HPLC-UV-MS (high performance liquid chromatography with ultra-violet detection coupled with mass spectrometry) measurements. <b>Conclusions:</b> LA-REIMS emerges as a promising technique, demonstrating potential suitability for semi-quantitative high-throughput metabolic stability in an optimized solvent environment.</p>","PeriodicalId":19894,"journal":{"name":"Pharmaceutics","volume":"16 10","pages":""},"PeriodicalIF":4.9000,"publicationDate":"2024-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11510429/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pharmaceutics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/pharmaceutics16101266","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Building extensive drug candidate libraries as early in the development pipeline as possible, with high-throughput in vitro absorption, distribution, metabolism, and excretion (ADME) profiling, is crucial for the selection of lead compounds to guide subsequent research and production phases. Traditionally, the analysis of metabolic stability assays heavily relies on high-throughput LC-MS/MS (liquid chromatography tandem mass spectrometry) techniques to meet with the lead profiling demands. Laser-assisted rapid evaporative ionization mass spectrometry (LA-REIMS) is a quick and efficient technique for characterizing complex biological samples without laborious sample preparation. Objective: In this study, using an automated LA-REIMS well plate reader, achieving an 8 s per sample measurement time, the oxidative metabolic stability of active drug agents was assessed using biomimetic metalloporphyrin-based oxidative model reactions. Results: The results obtained using the novel LA-REIMS-based protocol were compared to and corroborated by those obtained using conventional HPLC-UV-MS (high performance liquid chromatography with ultra-violet detection coupled with mass spectrometry) measurements. Conclusions: LA-REIMS emerges as a promising technique, demonstrating potential suitability for semi-quantitative high-throughput metabolic stability in an optimized solvent environment.

利用激光辅助快速蒸发电离质谱法 (LA-REIMS) 通过仿生金属卟啉催化反应进行高通量药物稳定性评估
背景:通过高通量体外吸收、分布、代谢和排泄(ADME)分析,在研发初期建立广泛的候选药物库,对于选择先导化合物以指导后续研究和生产阶段至关重要。传统上,代谢稳定性分析主要依靠高通量 LC-MS/MS(液相色谱串联质谱)技术来满足先导化合物分析的需求。激光辅助快速蒸发离子化质谱(LA-REIMS)是一种快速、高效的技术,可用于表征复杂的生物样品,而无需费力地制备样品。研究目的本研究使用自动 LA-REIMS 孔板阅读器,在每个样品 8 秒的测量时间内,利用基于仿金属卟啉的生物氧化模型反应评估了活性药物的氧化代谢稳定性。结果:使用基于 LA-REIMS 的新方案得出的结果与使用传统 HPLC-UV-MS(高效液相色谱-紫外检测-质谱联用)测量得出的结果进行了比较和印证。结论LA-REIMS 是一种很有前途的技术,它证明了在优化的溶剂环境中半定量高通量代谢稳定性的潜在适用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Pharmaceutics
Pharmaceutics Pharmacology, Toxicology and Pharmaceutics-Pharmaceutical Science
CiteScore
7.90
自引率
11.10%
发文量
2379
审稿时长
16.41 days
期刊介绍: Pharmaceutics (ISSN 1999-4923) is an open access journal which provides an advanced forum for the science and technology of pharmaceutics and biopharmaceutics. It publishes reviews, regular research papers, communications,  and short notes. Covered topics include pharmacokinetics, toxicokinetics, pharmacodynamics, pharmacogenetics and pharmacogenomics, and pharmaceutical formulation. Our aim is to encourage scientists to publish their experimental and theoretical details in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信