Development and preliminary evaluation of a novel preoperative index for quantitative analysis of photoreceptor loss in full-thickness macular holes.

IF 2.4 3区 医学 Q2 OPHTHALMOLOGY
Alberto Quarta, Andrea Govetto, Annamaria Porreca, Lisa Toto, Marta Di Nicola, Maria Ludovica Ruggeri, Matteo Gironi, Mario Nubile, Luca Agnifili, Mario R Romano, Rodolfo Mastropasqua
{"title":"Development and preliminary evaluation of a novel preoperative index for quantitative analysis of photoreceptor loss in full-thickness macular holes.","authors":"Alberto Quarta, Andrea Govetto, Annamaria Porreca, Lisa Toto, Marta Di Nicola, Maria Ludovica Ruggeri, Matteo Gironi, Mario Nubile, Luca Agnifili, Mario R Romano, Rodolfo Mastropasqua","doi":"10.1007/s00417-024-06654-z","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To identify novel quantitative parameters for evaluating photoreceptor loss in full-thickness macular holes (FTMH), exploring their potential clinical impact on postoperative functional and anatomical recovery.</p><p><strong>Methods: </strong>This pilot study enrolled 38 eyes from 38 patients diagnosed with FTMH. Preoperatively, eyes underwent analysis and were subsequently followed for six months post-surgery. Best-corrected visual acuity (BCVA) was recorded, and cross-sectional images of FTMH were obtained using B-scan optical coherence tomography (OCT) and en-face OCT. Quantitative assessment of ellipsoid zone (EZ) and external limiting membrane (ELM) integrity changes was conducted and correlated with postoperative anatomical and functional recovery. The photoreceptor Integrity Index (PIIN), calculated as the ratio of photoreceptor area to lumen hole area measured at customized segmentation, was correlated with the minimum and base diameters of the hole, positive change in BCVA, preoperative EZ defect (EZd), preoperative ELM defect (ELMd), and changes in EZ and ELM over the six-month follow-up period (∆-EZ and ∆-ELM). The main outcome measures focused on evaluating the effectiveness of PIIN in predicting postoperative anatomical and functional changes.</p><p><strong>Results: </strong>A higher PIIN correlated with a greater BCVA change over six months (p < 0.001). Univariate regression analysis using the PIIN as a predictor for positive change in BCVA (|∆-BCVA| [logMAR]) over time yielded significant results (p < 0.001). Additionally, the PIIN significantly correlated with EZd at baseline, ELM at baseline, and ELMd change over the six-month follow-up period.</p><p><strong>Conclusion: </strong>The PIIN shows promise as a tool for evaluating photoreceptor loss in macular holes and estimating postoperative functional and anatomical recovery.</p><p><strong>Key messages: </strong>What is known Previous studies have extensively used optical coherence tomography (OCT) to investigate various biomarkers for assessing patients with full-thickness macular hole (FTMH), without considering detailed MH ultrastructural features Existing indexes used to predict surgical outcomes for FTMH primarily depend on geometrical parameters and do not integrate detailed ultrastructural characteristics, such as cellular components.  What is new A novel concept introduces the quantitative measurement of residual photoreceptors located at the edge of FTMH. The Photoreceptor Integrity Index (PIIN) integrates different ultrastructural components of macular holes, aiming to become a valuable clinical tool to predict both anatomical and functional recovery outcomes following surgical intervention for FTMH.</p>","PeriodicalId":12795,"journal":{"name":"Graefe’s Archive for Clinical and Experimental Ophthalmology","volume":" ","pages":"637-645"},"PeriodicalIF":2.4000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11953196/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Graefe’s Archive for Clinical and Experimental Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00417-024-06654-z","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/26 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To identify novel quantitative parameters for evaluating photoreceptor loss in full-thickness macular holes (FTMH), exploring their potential clinical impact on postoperative functional and anatomical recovery.

Methods: This pilot study enrolled 38 eyes from 38 patients diagnosed with FTMH. Preoperatively, eyes underwent analysis and were subsequently followed for six months post-surgery. Best-corrected visual acuity (BCVA) was recorded, and cross-sectional images of FTMH were obtained using B-scan optical coherence tomography (OCT) and en-face OCT. Quantitative assessment of ellipsoid zone (EZ) and external limiting membrane (ELM) integrity changes was conducted and correlated with postoperative anatomical and functional recovery. The photoreceptor Integrity Index (PIIN), calculated as the ratio of photoreceptor area to lumen hole area measured at customized segmentation, was correlated with the minimum and base diameters of the hole, positive change in BCVA, preoperative EZ defect (EZd), preoperative ELM defect (ELMd), and changes in EZ and ELM over the six-month follow-up period (∆-EZ and ∆-ELM). The main outcome measures focused on evaluating the effectiveness of PIIN in predicting postoperative anatomical and functional changes.

Results: A higher PIIN correlated with a greater BCVA change over six months (p < 0.001). Univariate regression analysis using the PIIN as a predictor for positive change in BCVA (|∆-BCVA| [logMAR]) over time yielded significant results (p < 0.001). Additionally, the PIIN significantly correlated with EZd at baseline, ELM at baseline, and ELMd change over the six-month follow-up period.

Conclusion: The PIIN shows promise as a tool for evaluating photoreceptor loss in macular holes and estimating postoperative functional and anatomical recovery.

Key messages: What is known Previous studies have extensively used optical coherence tomography (OCT) to investigate various biomarkers for assessing patients with full-thickness macular hole (FTMH), without considering detailed MH ultrastructural features Existing indexes used to predict surgical outcomes for FTMH primarily depend on geometrical parameters and do not integrate detailed ultrastructural characteristics, such as cellular components.  What is new A novel concept introduces the quantitative measurement of residual photoreceptors located at the edge of FTMH. The Photoreceptor Integrity Index (PIIN) integrates different ultrastructural components of macular holes, aiming to become a valuable clinical tool to predict both anatomical and functional recovery outcomes following surgical intervention for FTMH.

开发并初步评估用于定量分析全厚黄斑孔内感光细胞损失的新型术前指数。
目的:确定评估全厚黄斑孔(FTMH)中感光细胞损失的新型定量参数,探索其对术后功能和解剖恢复的潜在临床影响:这项试验性研究共纳入了 38 名被诊断为 FTMH 患者的 38 只眼睛。术前对眼球进行分析,术后随访六个月。记录最佳矫正视力(BCVA),并使用 B 扫描光学相干断层扫描(OCT)和面内 OCT 获得 FTMH 的横截面图像。对椭圆带(EZ)和外限膜(ELM)的完整性变化进行了定量评估,并将其与术后解剖和功能恢复联系起来。光感受器完整性指数(PIIN)是根据定制分割时测量的光感受器面积与腔孔面积之比计算得出的,与腔孔的最小直径和基底直径、BCVA的正向变化、术前EZ缺损(EZd)、术前ELM缺损(ELMd)以及EZ和ELM在6个月随访期内的变化(∆-EZ和∆-ELM)相关。主要结果指标侧重于评估 PIIN 在预测术后解剖和功能变化方面的有效性:结果:PIIN 越高,BCVA 在 6 个月内的变化越大(p < 0.001)。将 PIIN 作为 BCVA(|Δ-BCVA|| [logMAR] )随时间发生正向变化的预测因子进行单变量回归分析,结果显著(p < 0.001)。此外,PIIN 与基线时的 EZd、基线时的 ELM 以及随访 6 个月期间 ELMd 的变化有显著相关性:结论:PIIN有望成为评估黄斑孔内光感受器损失以及估计术后功能和解剖恢复的工具:已知信息 以往的研究广泛使用光学相干断层扫描(OCT)来研究评估全厚黄斑孔(FTMH)患者的各种生物标志物,但没有考虑详细的MH超微结构特征。 新概念 新概念引入了对位于 FTMH 边缘的残余感光细胞的定量测量。光感受器完整性指数(PIIN)综合了黄斑孔的不同超微结构成分,旨在成为一种有价值的临床工具,用于预测 FTMH 手术干预后的解剖和功能恢复结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.40
自引率
7.40%
发文量
398
审稿时长
3 months
期刊介绍: Graefe''s Archive for Clinical and Experimental Ophthalmology is a distinguished international journal that presents original clinical reports and clini-cally relevant experimental studies. Founded in 1854 by Albrecht von Graefe to serve as a source of useful clinical information and a stimulus for discussion, the journal has published articles by leading ophthalmologists and vision research scientists for more than a century. With peer review by an international Editorial Board and prompt English-language publication, Graefe''s Archive provides rapid dissemination of clinical and clinically related experimental information.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信