Comparison of exercise training modalities and change in peak oxygen consumption in heart failure with preserved ejection fraction: a secondary analysis of the OptimEx-Clin trial.
Stephan Mueller, Marina Kabelac, Isabel Fegers-Wustrow, Ephraim B Winzer, Andreas B Gevaert, Paul Beckers, Bernhard Haller, Frank Edelmann, Jeffrey W Christle, Mark J Haykowsky, Vandana Sachdev, Dalane W Kitzman, Axel Linke, Volker Adams, Ulrik Wisloff, Burkert Pieske, Emeline van Craenenbroeck, Martin Halle
{"title":"Comparison of exercise training modalities and change in peak oxygen consumption in heart failure with preserved ejection fraction: a secondary analysis of the OptimEx-Clin trial.","authors":"Stephan Mueller, Marina Kabelac, Isabel Fegers-Wustrow, Ephraim B Winzer, Andreas B Gevaert, Paul Beckers, Bernhard Haller, Frank Edelmann, Jeffrey W Christle, Mark J Haykowsky, Vandana Sachdev, Dalane W Kitzman, Axel Linke, Volker Adams, Ulrik Wisloff, Burkert Pieske, Emeline van Craenenbroeck, Martin Halle","doi":"10.1093/eurjpc/zwae332","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>Exercise training (ET) is an effective therapy in heart failure with preserved ejection fraction (HFpEF), but the influence of different ET characteristics is unclear. We aimed to evaluate the associations between ET frequency, duration, intensity [% heart rate reserve (%HRR)] and estimated energy expenditure (EEE) with the change in peak oxygen consumption (V̇O2) over 3 months of moderate continuous training (MCT, 5×/week) or high-intensity interval training (HIIT, 3×/week) in HFpEF.</p><p><strong>Methods and results: </strong>ET duration and heart rate (HR) were recorded with a smartphone application. EEE was calculated using the HR data during ET and the individual HR-V̇O2 relationships during cardiopulmonary exercise testing. Differences between groups and associations between ET characteristics and peak V̇O2 change were assessed with linear regression analyses. Peak V̇O2 improved by 9.2 ± 13.2% after MCT and 8.7 ± 15.9% after HIIT (P = 0.67). The average EEE of 1 HIIT session was equivalent to ∼1.42 MCT sessions and when adjusted for EEE, the mean difference between MCT and HIIT was -0.1% (P = 0.98). For both MCT and HIIT, peak V̇O2 change was positively associated with ET frequency (MCT: R2 = 0.103; HIIT: R2 = 0.149) and duration/week (MCT: R2 = 0.120; HIIT: R2 = 0.125; all P < 0.05). Average %HRR was negatively associated with peak V̇O2 change in MCT (R2 = 0.101; P = 0.034), whereas no significant association was found in HIIT (P = 0.234). Multiple regression analyses explained ∼1/3 of the variance in peak V̇O2 change.</p><p><strong>Conclusion: </strong>In HFpEF, isocaloric HIIT and MCT seem to be equally effective over 3 months. Within each mode, increasing ET frequency or duration/week may be more effective to improve peak V̇O2 than increasing ET intensity.</p>","PeriodicalId":12051,"journal":{"name":"European journal of preventive cardiology","volume":null,"pages":null},"PeriodicalIF":8.4000,"publicationDate":"2024-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European journal of preventive cardiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/eurjpc/zwae332","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Aims: Exercise training (ET) is an effective therapy in heart failure with preserved ejection fraction (HFpEF), but the influence of different ET characteristics is unclear. We aimed to evaluate the associations between ET frequency, duration, intensity [% heart rate reserve (%HRR)] and estimated energy expenditure (EEE) with the change in peak oxygen consumption (V̇O2) over 3 months of moderate continuous training (MCT, 5×/week) or high-intensity interval training (HIIT, 3×/week) in HFpEF.
Methods and results: ET duration and heart rate (HR) were recorded with a smartphone application. EEE was calculated using the HR data during ET and the individual HR-V̇O2 relationships during cardiopulmonary exercise testing. Differences between groups and associations between ET characteristics and peak V̇O2 change were assessed with linear regression analyses. Peak V̇O2 improved by 9.2 ± 13.2% after MCT and 8.7 ± 15.9% after HIIT (P = 0.67). The average EEE of 1 HIIT session was equivalent to ∼1.42 MCT sessions and when adjusted for EEE, the mean difference between MCT and HIIT was -0.1% (P = 0.98). For both MCT and HIIT, peak V̇O2 change was positively associated with ET frequency (MCT: R2 = 0.103; HIIT: R2 = 0.149) and duration/week (MCT: R2 = 0.120; HIIT: R2 = 0.125; all P < 0.05). Average %HRR was negatively associated with peak V̇O2 change in MCT (R2 = 0.101; P = 0.034), whereas no significant association was found in HIIT (P = 0.234). Multiple regression analyses explained ∼1/3 of the variance in peak V̇O2 change.
Conclusion: In HFpEF, isocaloric HIIT and MCT seem to be equally effective over 3 months. Within each mode, increasing ET frequency or duration/week may be more effective to improve peak V̇O2 than increasing ET intensity.
期刊介绍:
European Journal of Preventive Cardiology (EJPC) is an official journal of the European Society of Cardiology (ESC) and the European Association of Preventive Cardiology (EAPC). The journal covers a wide range of scientific, clinical, and public health disciplines related to cardiovascular disease prevention, risk factor management, cardiovascular rehabilitation, population science and public health, and exercise physiology. The categories covered by the journal include classical risk factors and treatment, lifestyle risk factors, non-modifiable cardiovascular risk factors, cardiovascular conditions, concomitant pathological conditions, sport cardiology, diagnostic tests, care settings, epidemiology, pharmacology and pharmacotherapy, machine learning, and artificial intelligence.