Enhanced bone cement distribution in percutaneous vertebroplasty using a curved guide wire: a propensity score matching analysis.

IF 2.2 3区 医学 Q2 ORTHOPEDICS
Xuyan Hu, Zijin Zhang, Yisong Yang, Gang Zhang, Shen Cao, Bing Yu, Yubing Zhang
{"title":"Enhanced bone cement distribution in percutaneous vertebroplasty using a curved guide wire: a propensity score matching analysis.","authors":"Xuyan Hu, Zijin Zhang, Yisong Yang, Gang Zhang, Shen Cao, Bing Yu, Yubing Zhang","doi":"10.1186/s12891-024-07951-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Osteoporotic vertebral compression fractures (OVCF) severely affect the quality of life in the aged population. Percutaneous vertebroplasty (PVP) alleviates pain and stabilizes vertebrae, but suboptimal bone cement distribution can cause complications. Hence, this study aimed to clarify whether a new technique for PVP, using a curved guide wire, enhances the distribution of bone cement and improves clinical outcomes in patients with OVCF.</p><p><strong>Methods: </strong>Patients with single-segment OVCF underwent PVP or curved guide wire percutaneous vertebroplasty (C-PVP). Propensity score matching (PSM) was employed to balanced the baseline characteristics. The primary outcomes were the visual analog scale (VAS) and Oswestry disability index (ODI) scores. The secondary outcomes included assessments of bone cement distribution, bone cement injection volume, radiological parameters, and general clinical results. Additionally, Complications and adverse events were documented.</p><p><strong>Results: </strong>After PSM analysis, each group comprised 54 patients, which significantly reduced baseline differences. The C-PVP group showed better clinical outcomes compared to the traditional PVP group. One month after surgery, the C-PVP group had significantly lower VAS and ODI scores (p < 0.001). These improvements persisted at six months and the final follow-up. Additionally, bone cement distribution scores were better (p < 0.001), injection volume was higher (p = 0.03), leakage was less frequent (p = 0.02), and adjacent vertebral fractures occurred less frequently (p = 0.04) in the C-PVP group. Radiological parameters and overall clinical outcomes revealed no significant differences between the two groups.</p><p><strong>Conclusion: </strong>The use of curved guide wire in PVP significantly improves bone cement distribution and injection volume, resulting in better clinical efficacy in patients with OVCF.</p>","PeriodicalId":9189,"journal":{"name":"BMC Musculoskeletal Disorders","volume":null,"pages":null},"PeriodicalIF":2.2000,"publicationDate":"2024-10-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11495001/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Musculoskeletal Disorders","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12891-024-07951-8","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Osteoporotic vertebral compression fractures (OVCF) severely affect the quality of life in the aged population. Percutaneous vertebroplasty (PVP) alleviates pain and stabilizes vertebrae, but suboptimal bone cement distribution can cause complications. Hence, this study aimed to clarify whether a new technique for PVP, using a curved guide wire, enhances the distribution of bone cement and improves clinical outcomes in patients with OVCF.

Methods: Patients with single-segment OVCF underwent PVP or curved guide wire percutaneous vertebroplasty (C-PVP). Propensity score matching (PSM) was employed to balanced the baseline characteristics. The primary outcomes were the visual analog scale (VAS) and Oswestry disability index (ODI) scores. The secondary outcomes included assessments of bone cement distribution, bone cement injection volume, radiological parameters, and general clinical results. Additionally, Complications and adverse events were documented.

Results: After PSM analysis, each group comprised 54 patients, which significantly reduced baseline differences. The C-PVP group showed better clinical outcomes compared to the traditional PVP group. One month after surgery, the C-PVP group had significantly lower VAS and ODI scores (p < 0.001). These improvements persisted at six months and the final follow-up. Additionally, bone cement distribution scores were better (p < 0.001), injection volume was higher (p = 0.03), leakage was less frequent (p = 0.02), and adjacent vertebral fractures occurred less frequently (p = 0.04) in the C-PVP group. Radiological parameters and overall clinical outcomes revealed no significant differences between the two groups.

Conclusion: The use of curved guide wire in PVP significantly improves bone cement distribution and injection volume, resulting in better clinical efficacy in patients with OVCF.

在经皮椎体成形术中使用弯曲导丝增强骨水泥分布:倾向得分匹配分析。
背景:骨质疏松性椎体压缩骨折(OVCF骨质疏松性椎体压缩骨折(OVCF)严重影响老年人的生活质量。经皮椎体成形术(PVP)可减轻疼痛并稳定椎体,但骨水泥分布不均可能导致并发症。因此,本研究旨在阐明使用弯曲导丝的经皮椎体成形术新技术是否能改善骨水泥的分布,并改善 OVCF 患者的临床疗效:单节段 OVCF 患者接受了 PVP 或弯曲导丝经皮椎体成形术(C-PVP)。采用倾向评分匹配(PSM)平衡基线特征。主要结果为视觉模拟量表(VAS)和Oswestry残疾指数(ODI)评分。次要结果包括骨水泥分布评估、骨水泥注射量、放射学参数和一般临床结果。此外,还记录了并发症和不良事件:经过PSM分析,每组有54名患者,基线差异明显缩小。与传统 PVP 组相比,C-PVP 组的临床效果更好。术后一个月,C-PVP 组的 VAS 和 ODI 评分明显降低(p 结论:C-PVP 组的临床疗效优于传统 PVP 组:在 PVP 中使用弯曲导丝可明显改善骨水泥的分布和注射量,从而提高 OVCF 患者的临床疗效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
BMC Musculoskeletal Disorders
BMC Musculoskeletal Disorders 医学-风湿病学
CiteScore
3.80
自引率
8.70%
发文量
1017
审稿时长
3-6 weeks
期刊介绍: BMC Musculoskeletal Disorders is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of musculoskeletal disorders, as well as related molecular genetics, pathophysiology, and epidemiology. The scope of the Journal covers research into rheumatic diseases where the primary focus relates specifically to a component(s) of the musculoskeletal system.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信