Impact of microchannel width on axons for brain-on-chip applications†

IF 6.1 2区 工程技术 Q1 BIOCHEMICAL RESEARCH METHODS
Lab on a Chip Pub Date : 2024-10-23 DOI:10.1039/D4LC00440J
Katarina Vulić, Giulia Amos, Tobias Ruff, Revan Kasm, Stephan J. Ihle, Joël Küchler, János Vörös and Sean Weaver
{"title":"Impact of microchannel width on axons for brain-on-chip applications†","authors":"Katarina Vulić, Giulia Amos, Tobias Ruff, Revan Kasm, Stephan J. Ihle, Joël Küchler, János Vörös and Sean Weaver","doi":"10.1039/D4LC00440J","DOIUrl":null,"url":null,"abstract":"<p >Technologies for axon guidance for <em>in vitro</em> disease models and bottom up investigations are increasingly being used in neuroscience research. One of the most prevalent patterning methods is using polydimethylsiloxane (PDMS) microstructures due to compatibility with microscopy and electrophysiology which enables systematic tracking of axon development with precision and efficiency. Previous investigations of these guidance platforms have noted axons tend to follow edges and avoid sharp turns; however, the specific impact of spatial constraints remains only partially explored. We investigated the influence of microchannel width beyond a constriction point, as well as the number of available microchannels, on axon growth dynamics. Further, by manipulating the size of micron/submicron-sized PDMS tunnels we investigated the space restriction that prevents growth cone penetration showing that restrictions smaller than 350 nm were sufficient to exclude axons. This research offers insights into the interplay of spatial constraints, axon development, and neural behavior. The findings are important for designing <em>in vitro</em> platforms and <em>in vivo</em> neural interfaces for both fundamental neuroscience and translational applications in rapidly evolving neural implant technologies.</p>","PeriodicalId":85,"journal":{"name":"Lab on a Chip","volume":" 22","pages":" 5155-5166"},"PeriodicalIF":6.1000,"publicationDate":"2024-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://pubs.rsc.org/en/content/articlepdf/2024/lc/d4lc00440j?page=search","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Lab on a Chip","FirstCategoryId":"5","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2024/lc/d4lc00440j","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Technologies for axon guidance for in vitro disease models and bottom up investigations are increasingly being used in neuroscience research. One of the most prevalent patterning methods is using polydimethylsiloxane (PDMS) microstructures due to compatibility with microscopy and electrophysiology which enables systematic tracking of axon development with precision and efficiency. Previous investigations of these guidance platforms have noted axons tend to follow edges and avoid sharp turns; however, the specific impact of spatial constraints remains only partially explored. We investigated the influence of microchannel width beyond a constriction point, as well as the number of available microchannels, on axon growth dynamics. Further, by manipulating the size of micron/submicron-sized PDMS tunnels we investigated the space restriction that prevents growth cone penetration showing that restrictions smaller than 350 nm were sufficient to exclude axons. This research offers insights into the interplay of spatial constraints, axon development, and neural behavior. The findings are important for designing in vitro platforms and in vivo neural interfaces for both fundamental neuroscience and translational applications in rapidly evolving neural implant technologies.

Abstract Image

Abstract Image

微通道宽度对脑芯片应用中轴突的影响
用于体外疾病模型和自下而上研究的轴突导向技术正越来越多地应用于神经科学研究。最普遍的图案化方法之一是使用聚二甲基硅氧烷(PDMS)微结构,因为它与显微镜和电生理学兼容,可以精确高效地系统跟踪轴突的发育。以前对这些引导平台的研究注意到,轴突倾向于沿着边缘发展并避免急转弯;然而,空间限制的具体影响仍只得到了部分探讨。我们研究了收缩点以外的微通道宽度以及可用微通道数量对轴突生长动态的影响。此外,通过操纵微米/亚微米级 PDMS 通道的尺寸,我们研究了阻止生长锥穿透的空间限制,结果显示小于 350 纳米的限制足以将轴突排除在外。这项研究为空间限制、轴突发育和神经行为的相互作用提供了见解。这些发现对于设计体外平台和体内神经接口非常重要,既可用于基础神经科学,也可用于快速发展的神经植入技术的转化应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Lab on a Chip
Lab on a Chip 工程技术-化学综合
CiteScore
11.10
自引率
8.20%
发文量
434
审稿时长
2.6 months
期刊介绍: Lab on a Chip is the premiere journal that publishes cutting-edge research in the field of miniaturization. By their very nature, microfluidic/nanofluidic/miniaturized systems are at the intersection of disciplines, spanning fundamental research to high-end application, which is reflected by the broad readership of the journal. Lab on a Chip publishes two types of papers on original research: full-length research papers and communications. Papers should demonstrate innovations, which can come from technical advancements or applications addressing pressing needs in globally important areas. The journal also publishes Comments, Reviews, and Perspectives.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信