Self-actuated microfluidic chiplet for two-stage multiplex nucleic acid amplification assay†

IF 6.1 2区 工程技术 Q1 BIOCHEMICAL RESEARCH METHODS
Lab on a Chip Pub Date : 2024-10-22 DOI:10.1039/D4LC00752B
Felix Ansah, Marziyeh Hajialyani, Fatemeh Ahmadi, Yuming Gu, Ergün Alperay Tarım, Michael G. Mauk, Gordon A. Awandare and Haim H. Bau
{"title":"Self-actuated microfluidic chiplet for two-stage multiplex nucleic acid amplification assay†","authors":"Felix Ansah, Marziyeh Hajialyani, Fatemeh Ahmadi, Yuming Gu, Ergün Alperay Tarım, Michael G. Mauk, Gordon A. Awandare and Haim H. Bau","doi":"10.1039/D4LC00752B","DOIUrl":null,"url":null,"abstract":"<p >Effective diagnosis of comorbidities and infectious diseases that present similar symptoms requires point-of-need assays capable of co-detecting and differentiating among multiple co-endemic pathogens to enable timely, precision medicine and effective control measures. We previously developed a two-stage isothermal amplification assay dubbed Penn-RAMP to address this need. Penn-RAMP's first stage comprises a recombinase polymerase amplification (RPA), which amplifies all targets of interest in a single reaction chamber for a short duration. The RPA amplicons are then aliquoted into multiple loop-mediated isothermal amplification (LAMP) reaction chambers, each customized with pre-dried primers to amplify a single target or a group of targets. To enable Penn-RAMP at the point of need, we describe here a self-actuated Penn-RAMP chiplet that accommodates the Penn-RAMP assay. Our chiplet employs temperature-controlled phase change valves and capillary valves to self-aliquot first-stage amplicons into multiple (five) second-stage reaction chambers and to seal these chambers. The functionality of our device is demonstrated by co-detecting plant pathogens. The analytical performance of our chiplet is comparable to that of the benchtop Penn-RAMP assay and surpasses that of standalone LAMP assays. Our self-actuated chiplet can be operated standalone with purified nucleic acids or as the downstream amplification module of a sample preparation cassette.</p>","PeriodicalId":85,"journal":{"name":"Lab on a Chip","volume":" 23","pages":" 5175-5183"},"PeriodicalIF":6.1000,"publicationDate":"2024-10-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://pubs.rsc.org/en/content/articlepdf/2024/lc/d4lc00752b?page=search","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Lab on a Chip","FirstCategoryId":"5","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2024/lc/d4lc00752b","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Effective diagnosis of comorbidities and infectious diseases that present similar symptoms requires point-of-need assays capable of co-detecting and differentiating among multiple co-endemic pathogens to enable timely, precision medicine and effective control measures. We previously developed a two-stage isothermal amplification assay dubbed Penn-RAMP to address this need. Penn-RAMP's first stage comprises a recombinase polymerase amplification (RPA), which amplifies all targets of interest in a single reaction chamber for a short duration. The RPA amplicons are then aliquoted into multiple loop-mediated isothermal amplification (LAMP) reaction chambers, each customized with pre-dried primers to amplify a single target or a group of targets. To enable Penn-RAMP at the point of need, we describe here a self-actuated Penn-RAMP chiplet that accommodates the Penn-RAMP assay. Our chiplet employs temperature-controlled phase change valves and capillary valves to self-aliquot first-stage amplicons into multiple (five) second-stage reaction chambers and to seal these chambers. The functionality of our device is demonstrated by co-detecting plant pathogens. The analytical performance of our chiplet is comparable to that of the benchtop Penn-RAMP assay and surpasses that of standalone LAMP assays. Our self-actuated chiplet can be operated standalone with purified nucleic acids or as the downstream amplification module of a sample preparation cassette.

Abstract Image

用于两级多重核酸扩增检测的自驱动微流控芯片组
要有效诊断症状相似的合并症和传染病,需要能够共同检测和区分多种共同流行病原体的需求点检测方法,以便及时采取精准医疗和有效控制措施。为了满足这一需求,我们之前开发了一种两阶段等温扩增检测方法,称为宾夕法尼亚大学-RAMP。Penn-RAMP的第一阶段包括重组酶聚合酶扩增(RPA),在一个反应室中对所有感兴趣的目标进行短时间扩增。然后,RPA 扩增子被等分到多个环路介导等温扩增(LAMP)反应室中,每个反应室都有定制的预干燥引物,用于扩增单个或一组目标。为了在需要时实现宾夕法尼亚-RAMP,我们在此介绍一种可用于宾夕法尼亚-RAMP 分析的自驱动宾夕法尼亚-RAMP 芯片。我们的芯片采用温控相变阀和毛细管阀,将第一阶段的扩增子自流到多个(五个)第二阶段的反应室中,并密封这些反应室。我们的装置通过联合检测植物病原体证明了其功能。我们的芯片的分析性能与台式宾夕法尼亚-RAMP 分析法相当,并超过了独立的 LAMP 分析法。我们的自驱动芯片可与纯化核酸一起独立运行,也可作为样品制备盒的下游扩增模块。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Lab on a Chip
Lab on a Chip 工程技术-化学综合
CiteScore
11.10
自引率
8.20%
发文量
434
审稿时长
2.6 months
期刊介绍: Lab on a Chip is the premiere journal that publishes cutting-edge research in the field of miniaturization. By their very nature, microfluidic/nanofluidic/miniaturized systems are at the intersection of disciplines, spanning fundamental research to high-end application, which is reflected by the broad readership of the journal. Lab on a Chip publishes two types of papers on original research: full-length research papers and communications. Papers should demonstrate innovations, which can come from technical advancements or applications addressing pressing needs in globally important areas. The journal also publishes Comments, Reviews, and Perspectives.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信