Non-orthogonal spectacle correction for irregular astigmatism.

IF 2.8 3区 医学 Q1 OPHTHALMOLOGY
Adela Hulpus, Ritchie Henry, Lynn White, Bernardo T Lopes, Vito Romano, Ahmed Abass
{"title":"Non-orthogonal spectacle correction for irregular astigmatism.","authors":"Adela Hulpus, Ritchie Henry, Lynn White, Bernardo T Lopes, Vito Romano, Ahmed Abass","doi":"10.1111/opo.13405","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the potential improvement in visual acuity and subjective perception of image quality in patients with keratoconus using non-orthogonal correction (NOC) cylinder trial lenses where the steep and flat power meridians are set at angles less or greater than 90°.</p><p><strong>Methods: </strong>A set of NOC plano/cylindrical trial lenses, where the axes between the power meridians were set at a range of non-orthogonal angles, were used to refract 18 participants with keratoconus in whom 23 eyes were used for testing. Corneal elevation data were processed by bespoke MATLAB code from Pentacam Scheimpflug tomographer scans. Each participant first underwent subjective refraction using standard orthogonal cylinder trial lenses, and the monocular best-corrected visual acuity (BCVA, logMAR) was recorded for each eye. They then underwent a second subjective refraction using NOC cylinder trial lenses created for the study and completed a questionnaire to elicit their subjective appraisal of letter clarity and ghosting.</p><p><strong>Results: </strong>Fourteen (61%) eyes demonstrated an increase in objective BCVA with the NOC versus the orthogonal correction; seven (30%) eyes showed no change and in two (9%) eyes, the BCVA was slightly worse. Further, 87% and 79% experienced an increase in letter clarity and a reduction in ghosting, respectively, independent of changes in BCVA. The majority of non-orthogonal angles were in the range of 80°-85°, and it was possible to refine the cylinder and axis of the NOC further compared with the orthogonal correction. All but one of the participants said they would be interested in trying non-orthogonal spectacles if the opportunity arose.</p><p><strong>Conclusions: </strong>Correcting irregular astigmatism in keratoconic individuals with non-orthogonal spectacle correction may provide benefit in terms of increased visual acuity, improvements in letter clarity and a reduction of ghosting effects. This type of correction has the potential to improve the overall quality of life for patients with keratoconus.</p>","PeriodicalId":19522,"journal":{"name":"Ophthalmic and Physiological Optics","volume":null,"pages":null},"PeriodicalIF":2.8000,"publicationDate":"2024-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmic and Physiological Optics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/opo.13405","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To investigate the potential improvement in visual acuity and subjective perception of image quality in patients with keratoconus using non-orthogonal correction (NOC) cylinder trial lenses where the steep and flat power meridians are set at angles less or greater than 90°.

Methods: A set of NOC plano/cylindrical trial lenses, where the axes between the power meridians were set at a range of non-orthogonal angles, were used to refract 18 participants with keratoconus in whom 23 eyes were used for testing. Corneal elevation data were processed by bespoke MATLAB code from Pentacam Scheimpflug tomographer scans. Each participant first underwent subjective refraction using standard orthogonal cylinder trial lenses, and the monocular best-corrected visual acuity (BCVA, logMAR) was recorded for each eye. They then underwent a second subjective refraction using NOC cylinder trial lenses created for the study and completed a questionnaire to elicit their subjective appraisal of letter clarity and ghosting.

Results: Fourteen (61%) eyes demonstrated an increase in objective BCVA with the NOC versus the orthogonal correction; seven (30%) eyes showed no change and in two (9%) eyes, the BCVA was slightly worse. Further, 87% and 79% experienced an increase in letter clarity and a reduction in ghosting, respectively, independent of changes in BCVA. The majority of non-orthogonal angles were in the range of 80°-85°, and it was possible to refine the cylinder and axis of the NOC further compared with the orthogonal correction. All but one of the participants said they would be interested in trying non-orthogonal spectacles if the opportunity arose.

Conclusions: Correcting irregular astigmatism in keratoconic individuals with non-orthogonal spectacle correction may provide benefit in terms of increased visual acuity, improvements in letter clarity and a reduction of ghosting effects. This type of correction has the potential to improve the overall quality of life for patients with keratoconus.

非正交眼镜矫正不规则散光。
目的:研究使用非正交矫正(NOC)圆柱试戴镜片对角膜炎患者视力和图像质量主观感受的潜在改善效果:我们使用了一组非正交矫正圆柱镜片,对 18 名角膜炎患者进行了屈光测试,其中 23 只眼睛接受了测试。角膜抬高数据由定制的 MATLAB 代码从 Pentacam Scheimpflug 层析成像仪扫描中处理。每位受试者首先使用标准正交圆柱试戴镜片进行主观屈光度检查,并记录每只眼睛的单眼最佳矫正视力(BCVA,logMAR)。然后,他们使用为本研究制作的 NOC 柱面试戴镜片进行第二次主观屈光检查,并填写一份问卷,以了解他们对字母清晰度和重影的主观评价:与正交矫正相比,14 只眼睛(61%)的客观 BCVA 有所提高;7 只眼睛(30%)没有变化,2 只眼睛(9%)的 BCVA 略有下降。此外,分别有 87% 和 79% 的患者的字母清晰度有所提高,重影有所减少,这与 BCVA 的变化无关。大多数非正交角膜的角度在 80°-85° 之间,与正交矫正相比,非正交角膜的柱面和轴线有可能进一步细化。除一人外,所有参与者都表示,如果有机会,他们会有兴趣尝试非正交眼镜:结论:用非正交眼镜矫正角膜炎患者的不规则散光可提高视力、改善字母清晰度和减少重影效应。这种矫正方式有可能提高角膜炎患者的整体生活质量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.10
自引率
13.80%
发文量
135
审稿时长
6-12 weeks
期刊介绍: Ophthalmic & Physiological Optics, first published in 1925, is a leading international interdisciplinary journal that addresses basic and applied questions pertinent to contemporary research in vision science and optometry. OPO publishes original research papers, technical notes, reviews and letters and will interest researchers, educators and clinicians concerned with the development, use and restoration of vision.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信