Soodabeh Darzi, Samuel Arba-Mosquera, Kishore Raj Pradhan, Anika Förster, H Burkhard Dick, Suphi Taneri
{"title":"Refractive Coupling Effects in Keratorefractive Lenticule Extraction Procedures: A Machine Learning-Assisted Approach.","authors":"Soodabeh Darzi, Samuel Arba-Mosquera, Kishore Raj Pradhan, Anika Förster, H Burkhard Dick, Suphi Taneri","doi":"10.3928/1081597X-20240826-01","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the impact of refractive couplings in myopia and myopic astigmatism with two different keratorefractive lenticule extraction (KLEx) systems.</p><p><strong>Methods: </strong>This was a retrospective evaluation of refractive outcomes with two different lasers studying 2,841 eyes undergoing small incision lenticule extraction (SMILE) (VisuMax 500; Carl Zeiss Meditec) and 2,528 eyes undergoing SmartSight (ATOS; SCHWIND eye-tech-solutions GmbH). Coupling effects (derived from the ratio between partial slopes) were determined for sphere and cylinder and for spherical equivalent, cardinal, and oblique astigmatism separately.</p><p><strong>Results: </strong>Statistically significant coupling effects were observed for both the VisuMax and ATOS systems, as indicated by <i>P</i> values less than .05. For the VisuMax, a coupling effect of 8% of cylinder into sphere and a 2% coupling of sphere into cylinder was found. For the ATOS, the coupling effect of sphere into cylinder was 1%. A 3% coupling effect of oblique astigmatism into cardinal astigmatism in the VisuMax, and conversely, a 0.1% coupling effect of defocus into oblique astigmatism in the ATOS were found. In cases with no astigmatism plan, sphere had a 2% effect on induced astigmatism in the VisuMax and 0.6% in the ATOS. In high astigmatism plans, sphere had a significant 16% impact on cylinder in the VisuMax. Additionally, the effect of defocus on cardinal astigmatism was 6% in the VisuMax and 0.8% on oblique astigmatism in the ATOS.</p><p><strong>Conclusions: </strong>Despite the <i>P</i> values less than .05 indicating statistical significance, the observed coupling effects were consistently low, with magnitudes below 10%, even for astigmatism exceeding 2.50 diopters. These couplings may be partly attributed to cross-effects of torsional eye movements. Coupling values for KLEx were markedly lower than those reported for non-aspheric excimer laser ablations. The results suggest that surgical results may be refined further by optimizing nomograms to mitigate coupling effects. <b>[<i>J Refract Surg</i>. 2024;40(10):e706-e715.]</b>.</p>","PeriodicalId":16951,"journal":{"name":"Journal of refractive surgery","volume":"40 10","pages":"e706-e715"},"PeriodicalIF":2.9000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3928/1081597X-20240826-01","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To evaluate the impact of refractive couplings in myopia and myopic astigmatism with two different keratorefractive lenticule extraction (KLEx) systems.
Methods: This was a retrospective evaluation of refractive outcomes with two different lasers studying 2,841 eyes undergoing small incision lenticule extraction (SMILE) (VisuMax 500; Carl Zeiss Meditec) and 2,528 eyes undergoing SmartSight (ATOS; SCHWIND eye-tech-solutions GmbH). Coupling effects (derived from the ratio between partial slopes) were determined for sphere and cylinder and for spherical equivalent, cardinal, and oblique astigmatism separately.
Results: Statistically significant coupling effects were observed for both the VisuMax and ATOS systems, as indicated by P values less than .05. For the VisuMax, a coupling effect of 8% of cylinder into sphere and a 2% coupling of sphere into cylinder was found. For the ATOS, the coupling effect of sphere into cylinder was 1%. A 3% coupling effect of oblique astigmatism into cardinal astigmatism in the VisuMax, and conversely, a 0.1% coupling effect of defocus into oblique astigmatism in the ATOS were found. In cases with no astigmatism plan, sphere had a 2% effect on induced astigmatism in the VisuMax and 0.6% in the ATOS. In high astigmatism plans, sphere had a significant 16% impact on cylinder in the VisuMax. Additionally, the effect of defocus on cardinal astigmatism was 6% in the VisuMax and 0.8% on oblique astigmatism in the ATOS.
Conclusions: Despite the P values less than .05 indicating statistical significance, the observed coupling effects were consistently low, with magnitudes below 10%, even for astigmatism exceeding 2.50 diopters. These couplings may be partly attributed to cross-effects of torsional eye movements. Coupling values for KLEx were markedly lower than those reported for non-aspheric excimer laser ablations. The results suggest that surgical results may be refined further by optimizing nomograms to mitigate coupling effects. [J Refract Surg. 2024;40(10):e706-e715.].
期刊介绍:
The Journal of Refractive Surgery, the official journal of the International Society of Refractive Surgery, a partner of the American Academy of Ophthalmology, has been a monthly peer-reviewed forum for original research, review, and evaluation of refractive and lens-based surgical procedures for more than 30 years. Practical, clinically valuable articles provide readers with the most up-to-date information regarding advances in the field of refractive surgery. Begin to explore the Journal and all of its great benefits such as:
• Columns including “Translational Science,” “Surgical Techniques,” and “Biomechanics”
• Supplemental videos and materials available for many articles
• Access to current articles, as well as several years of archived content
• Articles posted online just 2 months after acceptance.