Comparisons of computer simulations and experimental data for capacitive hyperthermia using different split-phantoms.

IF 3 3区 医学 Q2 ONCOLOGY
International Journal of Hyperthermia Pub Date : 2024-01-01 Epub Date: 2024-10-20 DOI:10.1080/02656736.2024.2416999
Rami Muratoglu, Dominik Gerster, Jacek Nadobny, Alexander Hansch, Paul Krahl, Paraskevi Danai Veltsista, Marcus Beck, Daniel Zips, Pirus Ghadjar
{"title":"Comparisons of computer simulations and experimental data for capacitive hyperthermia using different split-phantoms.","authors":"Rami Muratoglu, Dominik Gerster, Jacek Nadobny, Alexander Hansch, Paul Krahl, Paraskevi Danai Veltsista, Marcus Beck, Daniel Zips, Pirus Ghadjar","doi":"10.1080/02656736.2024.2416999","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Several positive clinical trials have demonstrated that capacitive hyperthermia (CHT) improves the effectiveness of radiation therapy for the treatment of various cancer entities. However, the ability of CHT to induce significant heating throughout the body is under debate.</p><p><strong>Objectives: </strong>To perform a pilot study involving comparisons of computer simulations and experimental data using different split-phantoms to validate hyperthermia treatment modeling for pre-planning for a clinical CHT system and to investigate the feasibility of split-phantom measurements in capacitive hyperthermia.</p><p><strong>Materials and methods: </strong>The CHT system EHY-2030 (Oncotherm, Budapest, Hungary) was used. The system provides two electrode sizes, but only the smaller electrode, indicated as D200 electrode, was investigated in this pilot study. Horizontally and vertically splittable, different multi-slice phantoms with dielectric material properties simulating muscle and electrically low conductive fat were produced and heated. During the heating procedure, temperature-time curves were measured, and thermal images were captured. Specific absorption rate values were derived from the temperature rise (TR) values. Concomitantly, computer field simulations utilizing a detailed CAD-based model of the CHT system were performed using the simulation platform Sim4Life and compared with measurements.</p><p><strong>Results: </strong>For the investigated electrode D200 the system power of 75 W was applied, which is half of the maximum power of 150 W and lies in the range of usual values for this electrode applied in patient treatments in our clinic. For 75 W, a heating of 3.6 °C in 6 min in a depth of 1 cm in an agar-based, muscle tissue-equivalent phantom was achieved. The addition of a 1 cm thick, synthetic, low dielectric fat layer reduced the TR up until a depth of 8.5 cm by on average around 38% (from 8.5 cm onwards the absolute local TR is similar, deviations are ≤0.1 °C). In terms of point-to-point absolute SAR comparison (without any normalization), up to a depth of 11 cm in the phantoms central vertical plot, the simulation differs from the measured TR points by on average 25% (ranging from 7% to 36%) for the homogeneous phantom and by on average 43% (ranging from 26% to 60%) for the inhomogeneous phantom.</p><p><strong>Conclusion: </strong>Computer simulations and experimental data were compared for the CHT system EHY-2030 using the D200 electrode, applying a thermal imaging technique for different vertically splittable phantoms. This pilot study data can be used as a guidance regarding the expected heating for this commonly used electrode size but also to further elucidate the significance of non-thermal anticancer effects. Further studies are needed for different sizes and geometries of electrodes and phantoms.</p>","PeriodicalId":14137,"journal":{"name":"International Journal of Hyperthermia","volume":"41 1","pages":"2416999"},"PeriodicalIF":3.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Hyperthermia","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/02656736.2024.2416999","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/20 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Several positive clinical trials have demonstrated that capacitive hyperthermia (CHT) improves the effectiveness of radiation therapy for the treatment of various cancer entities. However, the ability of CHT to induce significant heating throughout the body is under debate.

Objectives: To perform a pilot study involving comparisons of computer simulations and experimental data using different split-phantoms to validate hyperthermia treatment modeling for pre-planning for a clinical CHT system and to investigate the feasibility of split-phantom measurements in capacitive hyperthermia.

Materials and methods: The CHT system EHY-2030 (Oncotherm, Budapest, Hungary) was used. The system provides two electrode sizes, but only the smaller electrode, indicated as D200 electrode, was investigated in this pilot study. Horizontally and vertically splittable, different multi-slice phantoms with dielectric material properties simulating muscle and electrically low conductive fat were produced and heated. During the heating procedure, temperature-time curves were measured, and thermal images were captured. Specific absorption rate values were derived from the temperature rise (TR) values. Concomitantly, computer field simulations utilizing a detailed CAD-based model of the CHT system were performed using the simulation platform Sim4Life and compared with measurements.

Results: For the investigated electrode D200 the system power of 75 W was applied, which is half of the maximum power of 150 W and lies in the range of usual values for this electrode applied in patient treatments in our clinic. For 75 W, a heating of 3.6 °C in 6 min in a depth of 1 cm in an agar-based, muscle tissue-equivalent phantom was achieved. The addition of a 1 cm thick, synthetic, low dielectric fat layer reduced the TR up until a depth of 8.5 cm by on average around 38% (from 8.5 cm onwards the absolute local TR is similar, deviations are ≤0.1 °C). In terms of point-to-point absolute SAR comparison (without any normalization), up to a depth of 11 cm in the phantoms central vertical plot, the simulation differs from the measured TR points by on average 25% (ranging from 7% to 36%) for the homogeneous phantom and by on average 43% (ranging from 26% to 60%) for the inhomogeneous phantom.

Conclusion: Computer simulations and experimental data were compared for the CHT system EHY-2030 using the D200 electrode, applying a thermal imaging technique for different vertically splittable phantoms. This pilot study data can be used as a guidance regarding the expected heating for this commonly used electrode size but also to further elucidate the significance of non-thermal anticancer effects. Further studies are needed for different sizes and geometries of electrodes and phantoms.

使用不同分象进行电容式热疗的计算机模拟与实验数据比较。
导言:多项积极的临床试验表明,电容性热疗(CHT)可提高放射治疗各种癌症的效果。然而,电容式热疗是否能在全身诱发显著的加热效果还存在争议:进行一项试验性研究,使用不同的分裂象对计算机模拟和实验数据进行比较,以验证热疗治疗模型,用于临床热疗系统的预先规划,并研究电容式热疗中分裂象测量的可行性:使用的热疗系统是 EHY-2030(匈牙利布达佩斯 Oncotherm 公司)。该系统提供两种尺寸的电极,但本试验研究只调查了较小的电极,即 D200 电极。制作并加热了可水平和垂直分割的不同多切片模型,这些模型具有模拟肌肉和低导电脂肪的介电材料特性。在加热过程中,测量了温度-时间曲线,并拍摄了热图像。根据温升(TR)值得出比吸收率值。同时,还利用模拟平台 Sim4Life 对基于 CAD 的热电联产系统详细模型进行了计算机现场模拟,并与测量结果进行了比较:对于所研究的电极 D200,所使用的系统功率为 75 W,是最大功率 150 W 的一半,处于本诊所用于患者治疗的电极的常用值范围内。功率为 75 W 时,在琼脂基肌肉组织等效模型中 1 厘米深处,6 分钟内可加热 3.6 °C。加入 1 厘米厚的合成低介电脂肪层后,直到 8.5 厘米深度的 TR 平均降低了约 38%(从 8.5 厘米开始,绝对局部 TR 相似,偏差小于 0.1 °C)。在点对点绝对 SAR 比较方面(未进行任何归一化处理),对于均质模型,模拟结果与测量 TR 点的平均差异为 25%(从 7% 到 36% 不等),而对于非均质模型,模拟结果与测量 TR 点的平均差异为 43%(从 26% 到 60% 不等):对使用 D200 电极的 CHT 系统 EHY-2030 的计算机模拟和实验数据进行了比较,并对不同的垂直可分割模型应用了热成像技术。这项试验性研究数据可用于指导这种常用电极尺寸的预期发热量,也可用于进一步阐明非热抗癌效应的重要性。还需要对不同尺寸和几何形状的电极和模型进行进一步研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.90
自引率
12.90%
发文量
153
审稿时长
6-12 weeks
期刊介绍: The International Journal of Hyperthermia
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信