Optimizing EUS-guided choledochoduodenostomy with lumen-apposing metal stents for primary drainage of malignant distal biliary obstruction (SCORPION-IIp): a prospective pilot study.
Jeska A Fritzsche, Paul Fockens, Marc G Besselink, Olivier R Busch, Freek Daams, Mattheus C B Wielenga, Johanna W Wilmink, Rogier P Voermans, Roy L J Van Wanrooij
{"title":"Optimizing EUS-guided choledochoduodenostomy with lumen-apposing metal stents for primary drainage of malignant distal biliary obstruction (SCORPION-IIp): a prospective pilot study.","authors":"Jeska A Fritzsche, Paul Fockens, Marc G Besselink, Olivier R Busch, Freek Daams, Mattheus C B Wielenga, Johanna W Wilmink, Rogier P Voermans, Roy L J Van Wanrooij","doi":"10.1016/j.gie.2024.10.012","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and aims: </strong>Biliary drainage by ERCP in patients with malignant distal bile duct obstruction (MBO) is frequently associated with adverse events, such as pancreatitis, hampering patient outcomes. EUS-guided choledochoduodenostomy (EUS-CDS) with a lumen-apposing metal stent (LAMS) is a promising alternative in patients with MBO but is associated with a worrisome risk of stent dysfunction. Placement of a fully covered self-expandable metal stent (FCSEMS) through the LAMS, thereby changing the axis of biliary drainage toward the descending duodenum, may decrease the risk of stent dysfunction while maintaining high technical success and low adverse event rates.</p><p><strong>Methods: </strong>This was a prospective single-center pilot study in patients with pathology-confirmed MBO without gastric outlet obstruction. The primary outcome was stent dysfunction, defined as recurrent jaundice after initial clinical success, ongoing jaundice in combination with persistent bile duct dilatation, or cholangitis.</p><p><strong>Results: </strong>Overall, 27 consecutive patients eligible for EUS-CDS were enrolled. The placement of a LAMS was successful in 24 of 27 patients (89%), and placement of a FCSEMS through the LAMS was successful in 20 of 24 (83%); in the remaining 4 patients, a coaxial double-pigtail plastic stent was placed. Two of these 20 patients experienced persistent jaundice requiring stent revision (10%), leading to a clinical success rate of 90%. No patients developed stent dysfunction after initial clinical success.</p><p><strong>Conclusions: </strong>This study showed a stent dysfunction rate of 10% after technically successful EUS-CDS with placement of a FCSEMS through the LAMS. Improving the design of LAMSs may further reduce the rate of stent dysfunction. (Clinical trial registration number: NCT05595122.).</p>","PeriodicalId":12542,"journal":{"name":"Gastrointestinal endoscopy","volume":" ","pages":""},"PeriodicalIF":6.7000,"publicationDate":"2024-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Gastrointestinal endoscopy","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.gie.2024.10.012","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background and aims: Biliary drainage by ERCP in patients with malignant distal bile duct obstruction (MBO) is frequently associated with adverse events, such as pancreatitis, hampering patient outcomes. EUS-guided choledochoduodenostomy (EUS-CDS) with a lumen-apposing metal stent (LAMS) is a promising alternative in patients with MBO but is associated with a worrisome risk of stent dysfunction. Placement of a fully covered self-expandable metal stent (FCSEMS) through the LAMS, thereby changing the axis of biliary drainage toward the descending duodenum, may decrease the risk of stent dysfunction while maintaining high technical success and low adverse event rates.
Methods: This was a prospective single-center pilot study in patients with pathology-confirmed MBO without gastric outlet obstruction. The primary outcome was stent dysfunction, defined as recurrent jaundice after initial clinical success, ongoing jaundice in combination with persistent bile duct dilatation, or cholangitis.
Results: Overall, 27 consecutive patients eligible for EUS-CDS were enrolled. The placement of a LAMS was successful in 24 of 27 patients (89%), and placement of a FCSEMS through the LAMS was successful in 20 of 24 (83%); in the remaining 4 patients, a coaxial double-pigtail plastic stent was placed. Two of these 20 patients experienced persistent jaundice requiring stent revision (10%), leading to a clinical success rate of 90%. No patients developed stent dysfunction after initial clinical success.
Conclusions: This study showed a stent dysfunction rate of 10% after technically successful EUS-CDS with placement of a FCSEMS through the LAMS. Improving the design of LAMSs may further reduce the rate of stent dysfunction. (Clinical trial registration number: NCT05595122.).
期刊介绍:
Gastrointestinal Endoscopy is a journal publishing original, peer-reviewed articles on endoscopic procedures for studying, diagnosing, and treating digestive diseases. It covers outcomes research, prospective studies, and controlled trials of new endoscopic instruments and treatment methods. The online features include full-text articles, video and audio clips, and MEDLINE links. The journal serves as an international forum for the latest developments in the specialty, offering challenging reports from authorities worldwide. It also publishes abstracts of significant articles from other clinical publications, accompanied by expert commentaries.