Feasibility of an artificial intelligence system for tumor response evaluation.

IF 2.9 3区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Nie Xiuli, Chen Hua, Gao Peng, Yu Hairong, Sun Meili, Yan Peng
{"title":"Feasibility of an artificial intelligence system for tumor response evaluation.","authors":"Nie Xiuli, Chen Hua, Gao Peng, Yu Hairong, Sun Meili, Yan Peng","doi":"10.1186/s12880-024-01460-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The objective of this study was to evaluate the feasibility of using Artificial Intelligence (AI) to measure the long-diameter of tumors for evaluating treatment response.</p><p><strong>Methods: </strong>Our study included 48 patients with lung-specific target lesions and conducted 277 measurements. The radiologists recorded the long-diameter in axial imaging plane of the target lesions for each measurement. Meanwhile, AI software was utilized to measure the long-diameter in both the axial imaging plane and in three dimensions (3D). Statistical analyses including the Bland-Altman plot, Spearman correlation analysis, and paired t-test to ascertain the accuracy and reliability of our findings.</p><p><strong>Results: </strong>The Bland-Altman plot showed that the AI measurements had a bias of -0.28 mm and had limits of agreement ranging from - 13.78 to 13.22 mm (P = 0.497), indicating agreement with the manual measurements. However, there was no agreement between the 3D measurements and the manual measurements, with P < 0.001. The paired t-test revealed no statistically significant difference between the manual measurements and AI measurements (P = 0.497), whereas a statistically significant difference was observed between the manual measurements and 3D measurements (P < 0.001).</p><p><strong>Conclusions: </strong>The application of AI in measuring the long-diameter of tumors had significantly improved efficiency and reduced the incidence of subjective measurement errors. This advancement facilitated more convenient and accurate tumor response evaluation.</p>","PeriodicalId":9020,"journal":{"name":"BMC Medical Imaging","volume":"24 1","pages":"280"},"PeriodicalIF":2.9000,"publicationDate":"2024-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11488245/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Medical Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12880-024-01460-9","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The objective of this study was to evaluate the feasibility of using Artificial Intelligence (AI) to measure the long-diameter of tumors for evaluating treatment response.

Methods: Our study included 48 patients with lung-specific target lesions and conducted 277 measurements. The radiologists recorded the long-diameter in axial imaging plane of the target lesions for each measurement. Meanwhile, AI software was utilized to measure the long-diameter in both the axial imaging plane and in three dimensions (3D). Statistical analyses including the Bland-Altman plot, Spearman correlation analysis, and paired t-test to ascertain the accuracy and reliability of our findings.

Results: The Bland-Altman plot showed that the AI measurements had a bias of -0.28 mm and had limits of agreement ranging from - 13.78 to 13.22 mm (P = 0.497), indicating agreement with the manual measurements. However, there was no agreement between the 3D measurements and the manual measurements, with P < 0.001. The paired t-test revealed no statistically significant difference between the manual measurements and AI measurements (P = 0.497), whereas a statistically significant difference was observed between the manual measurements and 3D measurements (P < 0.001).

Conclusions: The application of AI in measuring the long-diameter of tumors had significantly improved efficiency and reduced the incidence of subjective measurement errors. This advancement facilitated more convenient and accurate tumor response evaluation.

肿瘤反应评估人工智能系统的可行性。
目的:本研究旨在评估使用人工智能(AI)测量肿瘤长径以评估治疗反应的可行性:我们的研究纳入了48例肺特异性靶病变患者,进行了277次测量。放射科医生记录了每次测量的靶病灶轴向成像平面长径。同时,利用人工智能软件测量轴向成像平面和三维(3D)的长径。统计分析包括 Bland-Altman 图、Spearman 相关性分析和配对 t 检验,以确定研究结果的准确性和可靠性:布兰德-阿尔特曼图显示,人工智能测量结果的偏差为-0.28毫米,一致性范围为-13.78至13.22毫米(P=0.497),表明与人工测量结果一致。然而,三维测量结果与人工测量结果不一致,P 结论:人工智能在肿瘤长径测量中的应用大大提高了效率,减少了主观测量误差的发生。这一进步有助于更方便、更准确地评估肿瘤反应。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
BMC Medical Imaging
BMC Medical Imaging RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
4.60
自引率
3.70%
发文量
198
审稿时长
27 weeks
期刊介绍: BMC Medical Imaging is an open access journal publishing original peer-reviewed research articles in the development, evaluation, and use of imaging techniques and image processing tools to diagnose and manage disease.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信