David M. Selkowitz , Richard B. Souza , Christopher M. Powers
{"title":"The effect of femoral strapping on hip internal rotation and pain response in females with patellofemoral pain","authors":"David M. Selkowitz , Richard B. Souza , Christopher M. Powers","doi":"10.1016/j.gaitpost.2024.10.007","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Hip internal rotation has been reported to affect patellofemoral joint mechanics and contribute to patellofemoral pain (PFP). The SERF (<u>S</u>tability through <u>E</u>xternal <u>R</u>otation of the <u>F</u>emur) strap was designed to provide hip stability by pulling the thigh into external rotation during weight-bearing activities.</div></div><div><h3>Research question</h3><div>What are the effects of the SERF strap on hip internal rotation and pain response in females with PFP who present with hip internal rotation during weight-bearing activities?</div></div><div><h3>Methods</h3><div>Nineteen females between the ages of 18 and 45 with a diagnosis of PFP participated. Lower extremity kinematics were obtained during three tasks (drop-jump, unilateral step-down, over-ground running) under strap and no-strap conditions. A 10-cm visual analog scale (VAS) was used to assess pain response during each task and strap condition. Participants who exhibited at least 5 degrees of hip internal rotation during at least one of the 3 tasks were included in the final analysis. Peak hip internal rotation and mean VAS score were compared separately between strap conditions across tasks using 2 ×3 (strap condition x task) repeated-measures ANOVAs.</div></div><div><h3>Results</h3><div>Eighteen of the 19 females with PFP met the criteria for the presence of hip internal rotation. There was a significant reduction in peak hip internal rotation across tasks when wearing the SERF strap (mean ± sd = 7.4 ± 2.3, p<0.001). Additionally, the change in mean VAS pain score was significantly lower across tasks when wearing the SERF strap (1.0 ± 1.0, p=0.03).</div></div><div><h3>Significance</h3><div>The SERF strap was effective in reducing hip internal rotation and PFP during dynamic weight-bearing activities in symptomatic females. The SERF strap may be a useful treatment adjunct for persons with PFP who present with poor transverse plane control of the hip.</div></div>","PeriodicalId":12496,"journal":{"name":"Gait & posture","volume":"114 ","pages":"Pages 222-226"},"PeriodicalIF":2.2000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Gait & posture","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0966636224006349","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"NEUROSCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
Background
Hip internal rotation has been reported to affect patellofemoral joint mechanics and contribute to patellofemoral pain (PFP). The SERF (Stability through External Rotation of the Femur) strap was designed to provide hip stability by pulling the thigh into external rotation during weight-bearing activities.
Research question
What are the effects of the SERF strap on hip internal rotation and pain response in females with PFP who present with hip internal rotation during weight-bearing activities?
Methods
Nineteen females between the ages of 18 and 45 with a diagnosis of PFP participated. Lower extremity kinematics were obtained during three tasks (drop-jump, unilateral step-down, over-ground running) under strap and no-strap conditions. A 10-cm visual analog scale (VAS) was used to assess pain response during each task and strap condition. Participants who exhibited at least 5 degrees of hip internal rotation during at least one of the 3 tasks were included in the final analysis. Peak hip internal rotation and mean VAS score were compared separately between strap conditions across tasks using 2 ×3 (strap condition x task) repeated-measures ANOVAs.
Results
Eighteen of the 19 females with PFP met the criteria for the presence of hip internal rotation. There was a significant reduction in peak hip internal rotation across tasks when wearing the SERF strap (mean ± sd = 7.4 ± 2.3, p<0.001). Additionally, the change in mean VAS pain score was significantly lower across tasks when wearing the SERF strap (1.0 ± 1.0, p=0.03).
Significance
The SERF strap was effective in reducing hip internal rotation and PFP during dynamic weight-bearing activities in symptomatic females. The SERF strap may be a useful treatment adjunct for persons with PFP who present with poor transverse plane control of the hip.
期刊介绍:
Gait & Posture is a vehicle for the publication of up-to-date basic and clinical research on all aspects of locomotion and balance.
The topics covered include: Techniques for the measurement of gait and posture, and the standardization of results presentation; Studies of normal and pathological gait; Treatment of gait and postural abnormalities; Biomechanical and theoretical approaches to gait and posture; Mathematical models of joint and muscle mechanics; Neurological and musculoskeletal function in gait and posture; The evolution of upright posture and bipedal locomotion; Adaptations of carrying loads, walking on uneven surfaces, climbing stairs etc; spinal biomechanics only if they are directly related to gait and/or posture and are of general interest to our readers; The effect of aging and development on gait and posture; Psychological and cultural aspects of gait; Patient education.