Imasda Rahmatulloh , Retna Apsari , Syahidatun Na’imah , Tahta Amrillah , Samian , Dyah Hikmawati , Masruroh , Hendra Susanto , M. Yasin , Sulaiman W. Harun
{"title":"Graphene coated optical microfiber for aflatoxin B1 detection","authors":"Imasda Rahmatulloh , Retna Apsari , Syahidatun Na’imah , Tahta Amrillah , Samian , Dyah Hikmawati , Masruroh , Hendra Susanto , M. Yasin , Sulaiman W. Harun","doi":"10.1016/j.rio.2024.100746","DOIUrl":null,"url":null,"abstract":"<div><div>We proposed a graphene coated microfiber-based sensor for enhancing Aflatoxin B1 detection at room temperature. The heat-and-pull technique was used to fabricate the microfiber while the graphene layer was coated using a drop-casting technique. Aflatoxin samples are used as a sensor sensing area soaking solution, whereby the prepared graphene-coated microfiber was used as a sensor probe. The sensing is based on the modulation of transmission intensity and wavelength shift induced by the alteration of concentration of aflatoxin B1 from 0 ppm to 10 ppm. There is an increase in sensitivity from 0.129 dBm/ppm to 0.187 dBm/ppm and an increase in resolution from 0.17 ppm to 0.037 ppm by coating graphene on the microfiber sensor. For the graphene coated microfiber-based sensor, the wavelength shift from 1525.37 nm to 1525.19 nm was obtained when the aflatoxin B1 concentration was increased from 0 to 10 ppm. It reveals a sensitivity of 0.018 nm/ppm with a linearity of more than 90 %. This finding shows that the proposed sensor can be used to detect various concentration of Aflatoxin sample with the ability to offer real time measurement.</div></div>","PeriodicalId":21151,"journal":{"name":"Results in Optics","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Results in Optics","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666950124001433","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Physics and Astronomy","Score":null,"Total":0}
引用次数: 0
Abstract
We proposed a graphene coated microfiber-based sensor for enhancing Aflatoxin B1 detection at room temperature. The heat-and-pull technique was used to fabricate the microfiber while the graphene layer was coated using a drop-casting technique. Aflatoxin samples are used as a sensor sensing area soaking solution, whereby the prepared graphene-coated microfiber was used as a sensor probe. The sensing is based on the modulation of transmission intensity and wavelength shift induced by the alteration of concentration of aflatoxin B1 from 0 ppm to 10 ppm. There is an increase in sensitivity from 0.129 dBm/ppm to 0.187 dBm/ppm and an increase in resolution from 0.17 ppm to 0.037 ppm by coating graphene on the microfiber sensor. For the graphene coated microfiber-based sensor, the wavelength shift from 1525.37 nm to 1525.19 nm was obtained when the aflatoxin B1 concentration was increased from 0 to 10 ppm. It reveals a sensitivity of 0.018 nm/ppm with a linearity of more than 90 %. This finding shows that the proposed sensor can be used to detect various concentration of Aflatoxin sample with the ability to offer real time measurement.