Zeotropic mixture as a working fluid for cascade Rankine cycle-based reverse osmosis: Energy, exergy, and economic analysis

Q1 Chemical Engineering
{"title":"Zeotropic mixture as a working fluid for cascade Rankine cycle-based reverse osmosis: Energy, exergy, and economic analysis","authors":"","doi":"10.1016/j.ijft.2024.100890","DOIUrl":null,"url":null,"abstract":"<div><div>This study investigates the cascade Rankine cycle coupled with a reverse osmosis system for brackish groundwater treatment. The proposed system integrates a steam Rankine cycle (SRC) and an organic Rankine cycle (ORC) in a looped configuration, utilizing solar energy as a heat source. Each Rankine cycle is coupled with reverse osmosis (RO) to produce approximately 1 <em>m</em><sup>3</sup>/<em>h</em> of permeate from each RO system. The system is investigated with working fluid combinations from R1233zd(E), R1234ze(Z), and R1336mzz(Z). Through comprehensive energy, exergy, and economic analyses, the system's performance is evaluated with zeotropic mixtures compared to pure R1233zd(E). The results demonstrate reliable performance with zeotropic mixtures, particularly R1233zd(E)/R1234ze(Z) with a mass composition of 0.6/0.4, demonstrating the maximum ORC expander work output of 1.15 <em>kW</em>. Parametric analysis reveals remarkable performance under different ORC system parameters. Variations in SRC condensation pressure show a trade-off performance between SRC and ORC turbine work output. Exergy analysis reveals an increase in exergy destruction by evaporation-based ORC components and a reduction in exergy destruction by condensation-based components, emphasizing improved irreversibility during the condensation process. Economic analysis indicates a marginal impact on the overall system cost, with the treated water cost ranging from 0.891 to 0.919 $/<em>m</em><sup>3</sup>.</div></div>","PeriodicalId":36341,"journal":{"name":"International Journal of Thermofluids","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Thermofluids","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666202724003306","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Chemical Engineering","Score":null,"Total":0}
引用次数: 0

Abstract

This study investigates the cascade Rankine cycle coupled with a reverse osmosis system for brackish groundwater treatment. The proposed system integrates a steam Rankine cycle (SRC) and an organic Rankine cycle (ORC) in a looped configuration, utilizing solar energy as a heat source. Each Rankine cycle is coupled with reverse osmosis (RO) to produce approximately 1 m3/h of permeate from each RO system. The system is investigated with working fluid combinations from R1233zd(E), R1234ze(Z), and R1336mzz(Z). Through comprehensive energy, exergy, and economic analyses, the system's performance is evaluated with zeotropic mixtures compared to pure R1233zd(E). The results demonstrate reliable performance with zeotropic mixtures, particularly R1233zd(E)/R1234ze(Z) with a mass composition of 0.6/0.4, demonstrating the maximum ORC expander work output of 1.15 kW. Parametric analysis reveals remarkable performance under different ORC system parameters. Variations in SRC condensation pressure show a trade-off performance between SRC and ORC turbine work output. Exergy analysis reveals an increase in exergy destruction by evaporation-based ORC components and a reduction in exergy destruction by condensation-based components, emphasizing improved irreversibility during the condensation process. Economic analysis indicates a marginal impact on the overall system cost, with the treated water cost ranging from 0.891 to 0.919 $/m3.

Abstract Image

将沸腾混合物作为基于级联朗肯循环的反渗透的工作流体:能量、放能和经济分析
本研究探讨了用于咸水地下水处理的级联朗肯循环与反渗透系统。拟议的系统利用太阳能作为热源,将蒸汽朗肯循环 (SRC) 和有机朗肯循环 (ORC) 集成在一个循环配置中。每个朗肯循环与反渗透(RO)相结合,从每个反渗透系统产生约 1 立方米/小时的渗透液。该系统采用 R1233zd(E)、R1234ze(Z) 和 R1336mzz(Z) 工作流体组合进行研究。通过全面的能量、放能和经济分析,评估了与纯 R1233zd(E) 相比,使用各向同性混合物的系统性能。结果表明,各向同性混合物的性能可靠,特别是质量成分为 0.6/0.4 的 R1233zd(E)/R1234ze(Z),其 ORC 膨胀机的最大功输出为 1.15 千瓦。参数分析表明,在不同的 ORC 系统参数下都有出色的性能。SRC 冷凝压力的变化表明 SRC 和 ORC 涡轮工作输出之间存在性能权衡。放能分析表明,基于蒸发的 ORC 组件的放能破坏增加,而基于冷凝的组件的放能破坏减少,强调了冷凝过程中不可逆性的改善。经济分析表明,对整个系统成本的影响微乎其微,处理水的成本在 0.891 到 0.919 美元/立方米之间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
International Journal of Thermofluids
International Journal of Thermofluids Engineering-Mechanical Engineering
CiteScore
10.10
自引率
0.00%
发文量
111
审稿时长
66 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信