Improving the thermal and mechanical performance of cement-based mortars for reinforcing masonry structures: computational and experimental methods

IF 3.2 4区 工程技术 Q3 ENERGY & FUELS
Rabeb Ayed, Salwa Bouadila, Mariem Lazaar, Amira Dellagi, Luisa F. Cabeza
{"title":"Improving the thermal and mechanical performance of cement-based mortars for reinforcing masonry structures: computational and experimental methods","authors":"Rabeb Ayed,&nbsp;Salwa Bouadila,&nbsp;Mariem Lazaar,&nbsp;Amira Dellagi,&nbsp;Luisa F. Cabeza","doi":"10.1007/s12053-024-10263-4","DOIUrl":null,"url":null,"abstract":"<div><p>With an increasing energy deficit, improving the thermal properties of building materials is nowadays a priority. The incorporation of expanded polystyrene (EPS) and expanded perlite (EP) into cement mortar has shown enormous potential to improve overall thermal performance. This study aims to numerically evaluate the efficiency of using EPS and EP reinforced composites as coating mortars. First, several reinforced mortars were prepared by adding different proportions of EPS and EP to the cement mortar. The thermal, mechanical and microstructural performances of EPS and EP mortars were subsequently analyzed using Hot Disk and MATEST instruments as well as FTIR spectroscopy and XRD analysis. COMSOL Multiphysics software was then used to simulate the inner temperature variation of a hollow brick coated on both sides with the optimal reinforced mortar mix. The results showed that an increase in the amount of reinforcing material led to a reduction in both mechanical strength and thermal properties of the mortar. Optimum performance could be achieved by incorporating 2.5% expanded polystyrene into the mortar, which resulted in approximately 37%, 15%, and 26% reduction in thermal conductivity, thermal diffusivity, and volumetric heat capacity, respectively, compared to standard mortar. This thermal improvement was achieved while ensuring a satisfactory mechanical and chemical properties. By applying varying thicknesses of this reinforced mortar to the brick, the internal surface temperature was reduced by approximately 0.2–1.8 °C during periods of maximum flux exposure. Therefore, the application of these composites as a thermally enhanced coating mortar on building walls seems to be an adequate solution.</p><h3>Graphical abstract</h3>\n<div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>","PeriodicalId":537,"journal":{"name":"Energy Efficiency","volume":"17 7","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2024-09-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energy Efficiency","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s12053-024-10263-4","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

Abstract

With an increasing energy deficit, improving the thermal properties of building materials is nowadays a priority. The incorporation of expanded polystyrene (EPS) and expanded perlite (EP) into cement mortar has shown enormous potential to improve overall thermal performance. This study aims to numerically evaluate the efficiency of using EPS and EP reinforced composites as coating mortars. First, several reinforced mortars were prepared by adding different proportions of EPS and EP to the cement mortar. The thermal, mechanical and microstructural performances of EPS and EP mortars were subsequently analyzed using Hot Disk and MATEST instruments as well as FTIR spectroscopy and XRD analysis. COMSOL Multiphysics software was then used to simulate the inner temperature variation of a hollow brick coated on both sides with the optimal reinforced mortar mix. The results showed that an increase in the amount of reinforcing material led to a reduction in both mechanical strength and thermal properties of the mortar. Optimum performance could be achieved by incorporating 2.5% expanded polystyrene into the mortar, which resulted in approximately 37%, 15%, and 26% reduction in thermal conductivity, thermal diffusivity, and volumetric heat capacity, respectively, compared to standard mortar. This thermal improvement was achieved while ensuring a satisfactory mechanical and chemical properties. By applying varying thicknesses of this reinforced mortar to the brick, the internal surface temperature was reduced by approximately 0.2–1.8 °C during periods of maximum flux exposure. Therefore, the application of these composites as a thermally enhanced coating mortar on building walls seems to be an adequate solution.

Graphical abstract

改善用于加固砌体结构的水泥基砂浆的热性能和机械性能:计算和实验方法
随着能源短缺的日益严重,改善建筑材料的热性能已成为当务之急。在水泥砂浆中加入发泡聚苯乙烯(EPS)和膨胀珍珠岩(EP)已显示出改善整体热性能的巨大潜力。本研究旨在对使用 EPS 和 EP 增强复合材料作为涂层砂浆的效率进行数值评估。首先,在水泥砂浆中加入不同比例的 EPS 和 EP,制备了几种增强砂浆。随后使用 Hot Disk 和 MATEST 仪器以及傅立叶变换红外光谱和 XRD 分析了 EPS 和 EP 砂浆的热性能、机械性能和微观结构性能。然后使用 COMSOL Multiphysics 软件模拟了双面涂有最佳增强砂浆混合物的空心砖的内部温度变化。结果表明,增强材料用量的增加会导致砂浆机械强度和热性能的降低。通过在砂浆中加入 2.5% 的发泡聚苯乙烯可以达到最佳性能,与标准砂浆相比,热导率、热扩散率和体积热容分别降低了约 37%、15% 和 26%。在提高热性能的同时,还确保了令人满意的机械和化学特性。通过在砖上涂抹不同厚度的这种增强砂浆,在最大通量暴露期间,砖的内表面温度降低了约 0.2-1.8 °C。因此,在建筑墙体上应用这些复合材料作为热增强涂层砂浆似乎是一个适当的解决方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Energy Efficiency
Energy Efficiency ENERGY & FUELS-ENERGY & FUELS
CiteScore
5.80
自引率
6.50%
发文量
59
审稿时长
>12 weeks
期刊介绍: The journal Energy Efficiency covers wide-ranging aspects of energy efficiency in the residential, tertiary, industrial and transport sectors. Coverage includes a number of different topics and disciplines including energy efficiency policies at local, regional, national and international levels; long term impact of energy efficiency; technologies to improve energy efficiency; consumer behavior and the dynamics of consumption; socio-economic impacts of energy efficiency measures; energy efficiency as a virtual utility; transportation issues; building issues; energy management systems and energy services; energy planning and risk assessment; energy efficiency in developing countries and economies in transition; non-energy benefits of energy efficiency and opportunities for policy integration; energy education and training, and emerging technologies. See Aims and Scope for more details.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信