{"title":"Long-term outcomes of phacoemulsification with iStent inject® implantation in narrow angle glaucoma","authors":"Z. Cheng, T. Berman, A. Choudhary","doi":"10.1016/j.jfo.2024.104298","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><div>To assess the outcomes of phacoemulsification with iStent inject implantation (phaco-iStent) in patients with narrow angle glaucoma (NAG) at a single tertiary eye centre.</div></div><div><h3>Design</h3><div>Retrospective clinical cohort study.</div></div><div><h3>Methods</h3><div>Patients undergoing phaco-iStent for NAG between March 2018 and October 2020 under the glaucoma team at a tertiary referral hospital were included. Data was analysed from a surgical outcome database. Primary outcomes included postoperative change in the mean intraocular pressure (IOP) and medications. Success was defined at two IOP cut-off points:<!--> <!-->≤<!--> <!-->21<!--> <!-->mmHg and<!--> <!-->≤<!--> <!-->15<!--> <!-->mmHg with (qualified) or without (complete) drops. Failure was repeat glaucoma surgery or loss of light perception (LP).</div></div><div><h3>Results</h3><div>Fifty-seven eyes with a mean follow-up of 32<!--> <!-->months (range 12<!--> <!-->months to 36<!--> <!-->months) were included. Mean IOP changed from 19.7<!--> <!-->±<!--> <!-->4.2<!--> <!-->mmHg (range 12–28) to 14.0, 14.9 and 14.6 at 12, 24 and 36<!--> <!-->months. Drops reduced from 2.2<!--> <!-->±<!--> <!-->0.7 to 0.92<!--> <!-->±<!--> <!-->1.24 at the last follow-up. Complete success for an IOP<!--> <!-->≤<!--> <!-->21<!--> <!-->mmHg was 49%, 39%, 37% and qualified success was 96%, 92% and 95% at 12, 24 and 36<!--> <!-->months. An IOP<!--> <!-->≤<!--> <!-->15<!--> <!-->mmHg (qualified) was achieved in 74%, 58%, 54% at 6, 12, 24 and 36<!--> <!-->months. Three patients (5%) required further glaucoma surgery, one patient underwent selective laser trabeculoplasty and one patient requiring peri-ocular steroid treatment due to persistent cystoid macular oedema. There were no other long-term complications.</div></div><div><h3>Conclusion</h3><div>Phacoemulsification with iStent inject is a safe and effective surgical option in the management of narrow angle glaucoma.</div></div><div><h3>Objectif</h3><div>Évaluer les résultats de la phacoémulsification avec implantation d’iStent inject (phaco-iStent) chez les patients atteints de glaucome à angle étroit (GAE) dans un centre ophtalmologique tertiaire unique.</div></div><div><h3>Conception</h3><div>Étude de cohorte clinique rétrospective.</div></div><div><h3>Méthodes</h3><div>Les patients subissant une phaco-iStent pour un GAE entre mars 2018 et octobre 2020 sous l’équipe de glaucome d’un hôpital de référence tertiaire ont été inclus. Les données ont été analysées à partir d’une base de données de résultats chirurgicaux. Les critères principaux comprenaient la variation postopératoire de la pression intraoculaire moyenne (PIO) et des médicaments. La réussite a été définie à deux seuils de PIO :<!--> <!-->≤<!--> <!-->21<!--> <!-->mmHg et<!--> <!-->≤<!--> <!-->15<!--> <!-->mmHg avec (qualifiée) ou sans (complète) chutes. L’échec était défini comme une chirurgie du glaucome répétée ou une perte de la perception lumineuse (PL).</div></div><div><h3>Résultats</h3><div>Cinquante-sept yeux avec un suivi moyen de 32 mois (plage de 12 à 36 mois) ont été inclus. La PIO moyenne est passée de 19,7<!--> <!-->±<!--> <!-->4,2<!--> <!-->mmHg (plage de 12 à 28) à 14,0, 14,9, et 14,6 à 12, 24 et 36 mois. Le nombre de médicaments a diminué de 2,2<!--> <!-->±<!--> <!-->0,7 à 0,92<!--> <!-->±<!--> <!-->1,24 lors du dernier suivi. La réussite complète pour une PIO<!--> <!-->≤<!--> <!-->21<!--> <!-->mmHg était de 49 %, 39 %, 37 % et la réussite qualifiée était de 96 %, 92 % et 95 % à 6, 12, 24 et 36 mois. Une PIO<!--> <!-->≤<!--> <!-->15<!--> <!-->mmHg (qualifiée) a été atteinte dans 74 %, 58 %, 54 % à 12, 24 et 36 mois. Trois patients (5 %) ont nécessité une autre chirurgie du glaucome, un patient a subi une trabéculoplastie sélective au laser et un patient a nécessité un traitement stéroïdien péri-oculaire en raison d’un œdème maculaire kystoïde persistant. Aucune autre complication à long terme n’a été observée.</div></div><div><h3>Conclusion</h3><div>La phacoémulsification avec implantation d’iStent inject est une option chirurgicale sûre et efficace dans la prise en charge du glaucome à angle étroit.</div></div>","PeriodicalId":14777,"journal":{"name":"Journal Francais D Ophtalmologie","volume":"48 1","pages":"Article 104298"},"PeriodicalIF":1.2000,"publicationDate":"2024-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal Francais D Ophtalmologie","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0181551224002432","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose
To assess the outcomes of phacoemulsification with iStent inject implantation (phaco-iStent) in patients with narrow angle glaucoma (NAG) at a single tertiary eye centre.
Design
Retrospective clinical cohort study.
Methods
Patients undergoing phaco-iStent for NAG between March 2018 and October 2020 under the glaucoma team at a tertiary referral hospital were included. Data was analysed from a surgical outcome database. Primary outcomes included postoperative change in the mean intraocular pressure (IOP) and medications. Success was defined at two IOP cut-off points: ≤ 21 mmHg and ≤ 15 mmHg with (qualified) or without (complete) drops. Failure was repeat glaucoma surgery or loss of light perception (LP).
Results
Fifty-seven eyes with a mean follow-up of 32 months (range 12 months to 36 months) were included. Mean IOP changed from 19.7 ± 4.2 mmHg (range 12–28) to 14.0, 14.9 and 14.6 at 12, 24 and 36 months. Drops reduced from 2.2 ± 0.7 to 0.92 ± 1.24 at the last follow-up. Complete success for an IOP ≤ 21 mmHg was 49%, 39%, 37% and qualified success was 96%, 92% and 95% at 12, 24 and 36 months. An IOP ≤ 15 mmHg (qualified) was achieved in 74%, 58%, 54% at 6, 12, 24 and 36 months. Three patients (5%) required further glaucoma surgery, one patient underwent selective laser trabeculoplasty and one patient requiring peri-ocular steroid treatment due to persistent cystoid macular oedema. There were no other long-term complications.
Conclusion
Phacoemulsification with iStent inject is a safe and effective surgical option in the management of narrow angle glaucoma.
Objectif
Évaluer les résultats de la phacoémulsification avec implantation d’iStent inject (phaco-iStent) chez les patients atteints de glaucome à angle étroit (GAE) dans un centre ophtalmologique tertiaire unique.
Conception
Étude de cohorte clinique rétrospective.
Méthodes
Les patients subissant une phaco-iStent pour un GAE entre mars 2018 et octobre 2020 sous l’équipe de glaucome d’un hôpital de référence tertiaire ont été inclus. Les données ont été analysées à partir d’une base de données de résultats chirurgicaux. Les critères principaux comprenaient la variation postopératoire de la pression intraoculaire moyenne (PIO) et des médicaments. La réussite a été définie à deux seuils de PIO : ≤ 21 mmHg et ≤ 15 mmHg avec (qualifiée) ou sans (complète) chutes. L’échec était défini comme une chirurgie du glaucome répétée ou une perte de la perception lumineuse (PL).
Résultats
Cinquante-sept yeux avec un suivi moyen de 32 mois (plage de 12 à 36 mois) ont été inclus. La PIO moyenne est passée de 19,7 ± 4,2 mmHg (plage de 12 à 28) à 14,0, 14,9, et 14,6 à 12, 24 et 36 mois. Le nombre de médicaments a diminué de 2,2 ± 0,7 à 0,92 ± 1,24 lors du dernier suivi. La réussite complète pour une PIO ≤ 21 mmHg était de 49 %, 39 %, 37 % et la réussite qualifiée était de 96 %, 92 % et 95 % à 6, 12, 24 et 36 mois. Une PIO ≤ 15 mmHg (qualifiée) a été atteinte dans 74 %, 58 %, 54 % à 12, 24 et 36 mois. Trois patients (5 %) ont nécessité une autre chirurgie du glaucome, un patient a subi une trabéculoplastie sélective au laser et un patient a nécessité un traitement stéroïdien péri-oculaire en raison d’un œdème maculaire kystoïde persistant. Aucune autre complication à long terme n’a été observée.
Conclusion
La phacoémulsification avec implantation d’iStent inject est une option chirurgicale sûre et efficace dans la prise en charge du glaucome à angle étroit.
期刊介绍:
The Journal français d''ophtalmologie, official publication of the French Society of Ophthalmology, serves the French Speaking Community by publishing excellent research articles, communications of the French Society of Ophthalmology, in-depth reviews, position papers, letters received by the editor and a rich image bank in each issue. The scientific quality is guaranteed through unbiased peer-review, and the journal is member of the Committee of Publication Ethics (COPE). The editors strongly discourage editorial misconduct and in particular if duplicative text from published sources is identified without proper citation, the submission will not be considered for peer review and returned to the authors or immediately rejected.