Gait stability improves following unilateral total ankle arthroplasty.

IF 2.1 3区 医学 Q2 ORTHOPEDICS
Martin Barylak, Sara L Arena, Stephanie H Carpentier, Robin M Queen
{"title":"Gait stability improves following unilateral total ankle arthroplasty.","authors":"Martin Barylak, Sara L Arena, Stephanie H Carpentier, Robin M Queen","doi":"10.1002/jor.25992","DOIUrl":null,"url":null,"abstract":"<p><p>End-stage ankle arthritis is often treated surgically by total ankle arthroplasty (TAA) due to its potential to improve gait through increased joint range of motion and reduce pain. However, TAA's effect on gait stability is not well understood. This study explores the impact of TAA on gait stability, measured by Margin of Stability (MoS), in 148 patients with end-stage ankle arthritis. Kinematic data were collected pre-operatively, at 1-year post-op, and at 2-years post-op and the MoS was determined at heel strike and midstance for the anteroposterior (MoS<sub>AP</sub>) and mediolateral (MoS<sub>ML</sub>) directions. A linear mixed effects model including gait speed as a factor was used to assess the effects of limb, session, and their interaction on outcome measures. A significant interaction (p < 0.002) between limb (surgical, nonsurgical) and session (pre-op, 1-year post-op, 2-years post-op) was identified for each MoS variable of interest. Cumulatively, our results suggest that the nonsurgical limb, MoS<sub>AP</sub> at heel strike and MoS<sub>ML</sub> at midstance improved (increased) as time from surgery increased. These results suggest patients developed a compensatory movement pattern to navigate surgical limb single support. TAA reduces this compensation improving side-to-side symmetry, while not fully restoring symmetry by 2-years post-op. These results indicate that TAA could improve gait stability in patients with end-stage ankle arthritis, but further work is needed to understand the impact of TAA on altering fall risk.</p>","PeriodicalId":16650,"journal":{"name":"Journal of Orthopaedic Research®","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2024-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedic Research®","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/jor.25992","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

End-stage ankle arthritis is often treated surgically by total ankle arthroplasty (TAA) due to its potential to improve gait through increased joint range of motion and reduce pain. However, TAA's effect on gait stability is not well understood. This study explores the impact of TAA on gait stability, measured by Margin of Stability (MoS), in 148 patients with end-stage ankle arthritis. Kinematic data were collected pre-operatively, at 1-year post-op, and at 2-years post-op and the MoS was determined at heel strike and midstance for the anteroposterior (MoSAP) and mediolateral (MoSML) directions. A linear mixed effects model including gait speed as a factor was used to assess the effects of limb, session, and their interaction on outcome measures. A significant interaction (p < 0.002) between limb (surgical, nonsurgical) and session (pre-op, 1-year post-op, 2-years post-op) was identified for each MoS variable of interest. Cumulatively, our results suggest that the nonsurgical limb, MoSAP at heel strike and MoSML at midstance improved (increased) as time from surgery increased. These results suggest patients developed a compensatory movement pattern to navigate surgical limb single support. TAA reduces this compensation improving side-to-side symmetry, while not fully restoring symmetry by 2-years post-op. These results indicate that TAA could improve gait stability in patients with end-stage ankle arthritis, but further work is needed to understand the impact of TAA on altering fall risk.

单侧全踝关节置换术后步态稳定性得到改善。
晚期踝关节炎通常采用全踝关节置换术(TAA)进行手术治疗,因为这种手术可以通过增加关节活动范围来改善步态,并减轻疼痛。然而,TAA 对步态稳定性的影响尚不十分清楚。本研究探讨了踝关节置换术对步态稳定性的影响,通过对 148 名终末期踝关节炎患者的稳定性边际(MoS)进行测量。研究人员收集了术前、术后 1 年和术后 2 年的运动学数据,并测定了脚跟着地和中站时的前胸(MoSAP)和内外侧(MoSML)方向的 MoS。采用线性混合效应模型,将步速作为一个因子,评估肢体、疗程及其交互作用对结果测量的影响。随着手术时间的延长,脚跟着地时的交互作用(p AP)和中站时的MoSML均有明显改善(增加)。这些结果表明,患者形成了一种代偿运动模式,以适应手术肢体的单一支撑。TAA 可减少这种代偿,改善两侧对称性,但术后 2 年仍不能完全恢复对称性。这些结果表明,TAA可以改善终末期踝关节炎患者的步态稳定性,但要了解TAA对改变跌倒风险的影响还需要进一步的工作。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Orthopaedic Research®
Journal of Orthopaedic Research® 医学-整形外科
CiteScore
6.10
自引率
3.60%
发文量
261
审稿时长
3-6 weeks
期刊介绍: The Journal of Orthopaedic Research is the forum for the rapid publication of high quality reports of new information on the full spectrum of orthopaedic research, including life sciences, engineering, translational, and clinical studies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信