Absolute coronary flow and microvascular resistance before and after transcatheter aortic valve implantation.

IF 7.6 1区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS
Emanuele Gallinoro, Pasquale Paolisso, Dario Tino Bertolone, Giuseppe Esposito, Marta Belmonte, Attilio Leone, Michele Mattia Viscusi, Monika Shumkova, Cristina De Colle, Ivan Degrieck, Filip Casselman, Martin Penicka, Carlos Collet, Jeroen Sonck, Eric Wyffels, Jozef Bartunek, Bernard De Bruyne, Marc Vanderheyden, Emanuele Barbato
{"title":"Absolute coronary flow and microvascular resistance before and after transcatheter aortic valve implantation.","authors":"Emanuele Gallinoro, Pasquale Paolisso, Dario Tino Bertolone, Giuseppe Esposito, Marta Belmonte, Attilio Leone, Michele Mattia Viscusi, Monika Shumkova, Cristina De Colle, Ivan Degrieck, Filip Casselman, Martin Penicka, Carlos Collet, Jeroen Sonck, Eric Wyffels, Jozef Bartunek, Bernard De Bruyne, Marc Vanderheyden, Emanuele Barbato","doi":"10.4244/EIJ-D-24-00075","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Severe aortic stenosis (AS) is associated with left ventricular (LV) remodelling, likely causing alterations in coronary blood flow and microvascular resistance.</p><p><strong>Aims: </strong>We aimed to evaluate changes in absolute coronary flow and microvascular resistance in patients with AS undergoing transcatheter aortic valve implantation (TAVI).</p><p><strong>Methods: </strong>Consecutive patients with AS undergoing TAVI with non-obstructive coronary artery disease in the left anterior descending artery (LAD) were included. Absolute coronary flow (Q) and microvascular resistance (R<sub>μ</sub>) were measured in the LAD using continuous intracoronary thermodilution at rest and during hyperaemia before and after TAVI, and at 6-month follow-up. Total myocardial mass and LAD-specific mass were quantified by echocardiography and cardiac computed tomography. Regional myocardial perfusion (Q<sub>N</sub>) was calculated by dividing absolute flow by the subtended myocardial mass.</p><p><strong>Results: </strong>In 51 patients, Q and R were measured at rest and during hyperaemia before and after TAVI; in 20 (39%) patients, measurements were also obtained 6 months after TAVI. No changes occurred in resting and hyperaemic flow and resistance before and after TAVI nor after 6 months. However, at 6-month follow-up, a notable reverse LV remodelling resulted in a significant increase in hyperaemic perfusion (Q<sub>N,hyper</sub>: 0.86 [interquartile range {IQR} 0.691.06] vs 1.20 [IQR 0.99-1.32] mL/min/g; p=0.008; pre-TAVI and follow-up, respectively) but not in resting perfusion (Q<sub>N,rest</sub>: 0.34 [IQR 0.30-0.48] vs 0.47 [IQR 0.36-0.67] mL/min/g; p=0.06).</p><p><strong>Conclusions: </strong>Immediately after TAVI, no changes occurred in absolute coronary flow or coronary flow reserve. Over time, the remodelling of the left ventricle is associated with increased hyperaemic perfusion.</p>","PeriodicalId":54378,"journal":{"name":"Eurointervention","volume":"20 19","pages":"e1248-e1528"},"PeriodicalIF":7.6000,"publicationDate":"2024-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11443252/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eurointervention","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4244/EIJ-D-24-00075","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Severe aortic stenosis (AS) is associated with left ventricular (LV) remodelling, likely causing alterations in coronary blood flow and microvascular resistance.

Aims: We aimed to evaluate changes in absolute coronary flow and microvascular resistance in patients with AS undergoing transcatheter aortic valve implantation (TAVI).

Methods: Consecutive patients with AS undergoing TAVI with non-obstructive coronary artery disease in the left anterior descending artery (LAD) were included. Absolute coronary flow (Q) and microvascular resistance (Rμ) were measured in the LAD using continuous intracoronary thermodilution at rest and during hyperaemia before and after TAVI, and at 6-month follow-up. Total myocardial mass and LAD-specific mass were quantified by echocardiography and cardiac computed tomography. Regional myocardial perfusion (QN) was calculated by dividing absolute flow by the subtended myocardial mass.

Results: In 51 patients, Q and R were measured at rest and during hyperaemia before and after TAVI; in 20 (39%) patients, measurements were also obtained 6 months after TAVI. No changes occurred in resting and hyperaemic flow and resistance before and after TAVI nor after 6 months. However, at 6-month follow-up, a notable reverse LV remodelling resulted in a significant increase in hyperaemic perfusion (QN,hyper: 0.86 [interquartile range {IQR} 0.691.06] vs 1.20 [IQR 0.99-1.32] mL/min/g; p=0.008; pre-TAVI and follow-up, respectively) but not in resting perfusion (QN,rest: 0.34 [IQR 0.30-0.48] vs 0.47 [IQR 0.36-0.67] mL/min/g; p=0.06).

Conclusions: Immediately after TAVI, no changes occurred in absolute coronary flow or coronary flow reserve. Over time, the remodelling of the left ventricle is associated with increased hyperaemic perfusion.

经导管主动脉瓣植入术前后的绝对冠脉流量和微血管阻力。
背景:目的:我们旨在评估接受经导管主动脉瓣植入术(TAVI)的AS患者的冠状动脉绝对血流量和微血管阻力的变化:方法:纳入接受经导管主动脉瓣植入术(TAVI)且左前降支动脉(LAD)无阻塞性冠状动脉疾病的AS患者。在 TAVI 前后及随访 6 个月时,使用连续冠状动脉内热稀释法测量静息时和高血容量时 LAD 的绝对冠状动脉流量 (Q) 和微血管阻力 (Rμ)。通过超声心动图和心脏计算机断层扫描对心肌总质量和左心室特异性质量进行量化。区域心肌灌注量(QN)通过绝对血流量除以心肌质量计算得出:51 名患者在 TAVI 手术前后的静息状态和高血流状态下测量了 Q 和 R;20 名患者(39%)在 TAVI 手术后 6 个月也进行了测量。在 TAVI 前后和 6 个月后,静息和高血流时的血流和阻力均未发生变化。然而,在 6 个月的随访中,左心室明显的反向重塑导致高血流灌注显著增加(QN,hyper:0.86[四分位数间距{IQR} 0.691.06] vs 1.20 [IQR 0.99-1.32] mL/min/g;P=0.008;分别为TAVI前和随访时),但静息灌注量没有增加(QN,rest: 0.34 [IQR 0.30-0.48] vs 0.47 [IQR 0.36-0.67] mL/min/g;P=0.06):结论:TAVI术后,冠状动脉绝对血流量或冠状动脉血流储备没有发生变化。随着时间的推移,左心室的重塑与高血流灌注增加有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Eurointervention
Eurointervention CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
10.30
自引率
4.80%
发文量
380
审稿时长
3-8 weeks
期刊介绍: EuroIntervention Journal is an international, English language, peer-reviewed journal whose aim is to create a community of high quality research and education in the field of percutaneous and surgical cardiovascular interventions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信