{"title":"Deep learning-based defacing tool for CT angiography: CTA-DEFACE.","authors":"Mustafa Ahmed Mahmutoglu, Aditya Rastogi, Marianne Schell, Martha Foltyn-Dumitru, Michael Baumgartner, Klaus Hermann Maier-Hein, Katerina Deike-Hofmann, Alexander Radbruch, Martin Bendszus, Gianluca Brugnara, Philipp Vollmuth","doi":"10.1186/s41747-024-00510-9","DOIUrl":null,"url":null,"abstract":"<p><p>The growing use of artificial neural network (ANN) tools for computed tomography angiography (CTA) data analysis underscores the necessity for elevated data protection measures. We aimed to establish an automated defacing pipeline for CTA data. In this retrospective study, CTA data from multi-institutional cohorts were utilized to annotate facemasks (n = 100) and train an ANN model, subsequently tested on an external institution's dataset (n = 50) and compared to a publicly available defacing algorithm. Face detection (MTCNN) and verification (FaceNet) networks were applied to measure the similarity between the original and defaced CTA images. Dice similarity coefficient (DSC), face detection probability, and face similarity measures were calculated to evaluate model performance. The CTA-DEFACE model effectively segmented soft face tissue in CTA data achieving a DSC of 0.94 ± 0.02 (mean ± standard deviation) on the test set. Our model was benchmarked against a publicly available defacing algorithm. After applying face detection and verification networks, our model showed substantially reduced face detection probability (p < 0.001) and similarity to the original CTA image (p < 0.001). The CTA-DEFACE model enabled robust and precise defacing of CTA data. The trained network is publicly accessible at www.github.com/neuroAI-HD/CTA-DEFACE . RELEVANCE STATEMENT: The ANN model CTA-DEFACE, developed for automatic defacing of CT angiography images, achieves significantly lower face detection probabilities and greater dissimilarity from the original images compared to a publicly available model. The algorithm has been externally validated and is publicly accessible. KEY POINTS: The developed ANN model (CTA-DEFACE) automatically generates facemasks for CT angiography images. CTA-DEFACE offers superior deidentification capabilities compared to a publicly available model. By means of graphics processing unit optimization, our model ensures rapid processing of medical images. Our model underwent external validation, underscoring its reliability for real-world application.</p>","PeriodicalId":36926,"journal":{"name":"European Radiology Experimental","volume":"8 1","pages":"111"},"PeriodicalIF":3.7000,"publicationDate":"2024-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11465008/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Radiology Experimental","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s41747-024-00510-9","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

The growing use of artificial neural network (ANN) tools for computed tomography angiography (CTA) data analysis underscores the necessity for elevated data protection measures. We aimed to establish an automated defacing pipeline for CTA data. In this retrospective study, CTA data from multi-institutional cohorts were utilized to annotate facemasks (n = 100) and train an ANN model, subsequently tested on an external institution's dataset (n = 50) and compared to a publicly available defacing algorithm. Face detection (MTCNN) and verification (FaceNet) networks were applied to measure the similarity between the original and defaced CTA images. Dice similarity coefficient (DSC), face detection probability, and face similarity measures were calculated to evaluate model performance. The CTA-DEFACE model effectively segmented soft face tissue in CTA data achieving a DSC of 0.94 ± 0.02 (mean ± standard deviation) on the test set. Our model was benchmarked against a publicly available defacing algorithm. After applying face detection and verification networks, our model showed substantially reduced face detection probability (p < 0.001) and similarity to the original CTA image (p < 0.001). The CTA-DEFACE model enabled robust and precise defacing of CTA data. The trained network is publicly accessible at www.github.com/neuroAI-HD/CTA-DEFACE . RELEVANCE STATEMENT: The ANN model CTA-DEFACE, developed for automatic defacing of CT angiography images, achieves significantly lower face detection probabilities and greater dissimilarity from the original images compared to a publicly available model. The algorithm has been externally validated and is publicly accessible. KEY POINTS: The developed ANN model (CTA-DEFACE) automatically generates facemasks for CT angiography images. CTA-DEFACE offers superior deidentification capabilities compared to a publicly available model. By means of graphics processing unit optimization, our model ensures rapid processing of medical images. Our model underwent external validation, underscoring its reliability for real-world application.

基于深度学习的 CT 血管造影涂片工具:CTA-DEFACE
人工神经网络(ANN)工具在计算机断层扫描血管造影(CTA)数据分析中的应用日益广泛,这凸显了加强数据保护措施的必要性。我们的目标是为 CTA 数据建立一个自动去污管道。在这项回顾性研究中,我们利用来自多机构队列的 CTA 数据来注释面罩(n = 100)并训练一个 ANN 模型,随后在外部机构的数据集(n = 50)上进行测试,并与公开可用的去污算法进行比较。应用人脸检测(MTCNN)和验证(FaceNet)网络来测量原始和污损 CTA 图像之间的相似性。通过计算骰子相似系数(DSC)、人脸检测概率和人脸相似度量来评估模型性能。CTA-DEFACE 模型有效地分割了 CTA 数据中的软脸部组织,测试集上的 DSC 为 0.94 ± 0.02(平均值 ± 标准偏差)。我们的模型与公开的玷污算法进行了基准测试。在应用人脸检测和验证网络后,我们的模型大幅降低了人脸检测概率(p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
European Radiology Experimental
European Radiology Experimental Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
6.70
自引率
2.60%
发文量
56
审稿时长
18 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信