Histotripsy-induced bactericidal activity correlates to size of cavitation cloud in vitro.

IF 3 2区 工程技术 Q1 ACOUSTICS
Pratik A Ambekar, Yak-Nam Wang, Tatiana Khokhlova, Gilles Thomas, Pavel Rosnitskiy, Kaizer Contreras, Daniel F Leotta, Adam D Maxwell, Matthew Bruce, Shelby Pierson, Stephanie Totten, Yashwanth Nanda Kumar, Jeff Thiel, Keith Chan, W Conrad Liles, Evan P Dellinger, Adeyinka Adedipe, Wayne Monsky, Thomas J Matula
{"title":"Histotripsy-induced bactericidal activity correlates to size of cavitation cloud in vitro.","authors":"Pratik A Ambekar, Yak-Nam Wang, Tatiana Khokhlova, Gilles Thomas, Pavel Rosnitskiy, Kaizer Contreras, Daniel F Leotta, Adam D Maxwell, Matthew Bruce, Shelby Pierson, Stephanie Totten, Yashwanth Nanda Kumar, Jeff Thiel, Keith Chan, W Conrad Liles, Evan P Dellinger, Adeyinka Adedipe, Wayne Monsky, Thomas J Matula","doi":"10.1109/TUFFC.2024.3476438","DOIUrl":null,"url":null,"abstract":"<p><p>Large abscesses are walled-off collections of pus and bacteria that often do not respond to antibiotic therapy. Standard of care involves percutaneous placement of indwelling catheter(s) for drainage, a long and uncomfortable process with high rehospitalization rates. The long-term goal of this work is to develop therapeutic ultrasound approaches to eradicate bacteria within abscesses as a noninvasive therapeutic alternative. Inertial cavitation induced by short pulses of focused ultrasound (histotripsy) is known to generate lethal mechanical damage in bacteria. Prior studies with Escherichia coli (E. coli) in suspension demonstrated that bactericidal effects increase with increasing peak negative amplitude, treatment time and duty cycle. The current study investigated correlates of bactericidal activity with histotripsy cavitation cloud size. Histotripsy was applied to E. coli suspensions in 10-mL sample vials at 810 kHz, 1.2 MHz, or 3.25 MHz for 40 minutes. The cavitation activity in the sample vials was separately observed with high-speed photography. The cavitation cloud area was quantified from those images. A linear relationship was observed between bacterial inactivation and cavitation cloud size (R<sup>2</sup> = 0.96), regardless of the acoustic parameters (specifically frequency, pulse duration and power) used to produce the cloud.</p>","PeriodicalId":13322,"journal":{"name":"IEEE transactions on ultrasonics, ferroelectrics, and frequency control","volume":"PP ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2024-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on ultrasonics, ferroelectrics, and frequency control","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1109/TUFFC.2024.3476438","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

Abstract

Large abscesses are walled-off collections of pus and bacteria that often do not respond to antibiotic therapy. Standard of care involves percutaneous placement of indwelling catheter(s) for drainage, a long and uncomfortable process with high rehospitalization rates. The long-term goal of this work is to develop therapeutic ultrasound approaches to eradicate bacteria within abscesses as a noninvasive therapeutic alternative. Inertial cavitation induced by short pulses of focused ultrasound (histotripsy) is known to generate lethal mechanical damage in bacteria. Prior studies with Escherichia coli (E. coli) in suspension demonstrated that bactericidal effects increase with increasing peak negative amplitude, treatment time and duty cycle. The current study investigated correlates of bactericidal activity with histotripsy cavitation cloud size. Histotripsy was applied to E. coli suspensions in 10-mL sample vials at 810 kHz, 1.2 MHz, or 3.25 MHz for 40 minutes. The cavitation activity in the sample vials was separately observed with high-speed photography. The cavitation cloud area was quantified from those images. A linear relationship was observed between bacterial inactivation and cavitation cloud size (R2 = 0.96), regardless of the acoustic parameters (specifically frequency, pulse duration and power) used to produce the cloud.

组氨诱导的杀菌活性与体外空化云的大小有关。
大脓肿是脓液和细菌的壁状聚集,通常对抗生素治疗无效。标准的治疗方法包括经皮置入留置导管进行引流,这是一个漫长而不舒适的过程,再住院率很高。这项工作的长期目标是开发超声治疗方法,以消灭脓肿内的细菌,作为一种非侵入性的替代治疗方法。众所周知,聚焦超声短脉冲诱导的惯性空化(组织损伤)会对细菌造成致命的机械损伤。之前对悬浮液中的大肠杆菌(E. coli)进行的研究表明,杀菌效果会随着负振幅峰值、治疗时间和占空比的增加而增强。本研究调查了杀菌活性与组旋空化云大小的相关性。在 810 kHz、1.2 MHz 或 3.25 MHz 频率下对 10 毫升样品瓶中的大肠杆菌悬浮液进行组旋,持续 40 分钟。通过高速摄影分别观察样品瓶中的空化活动。根据这些图像对空化云面积进行量化。细菌灭活与空化云大小之间呈线性关系(R2 = 0.96),与产生空化云的声学参数(特别是频率、脉冲持续时间和功率)无关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.70
自引率
16.70%
发文量
583
审稿时长
4.5 months
期刊介绍: IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control includes the theory, technology, materials, and applications relating to: (1) the generation, transmission, and detection of ultrasonic waves and related phenomena; (2) medical ultrasound, including hyperthermia, bioeffects, tissue characterization and imaging; (3) ferroelectric, piezoelectric, and piezomagnetic materials, including crystals, polycrystalline solids, films, polymers, and composites; (4) frequency control, timing and time distribution, including crystal oscillators and other means of classical frequency control, and atomic, molecular and laser frequency control standards. Areas of interest range from fundamental studies to the design and/or applications of devices and systems.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信