Ultraviolet (UV-C) Light Systems for the Inactivation of Feline Calicivirus and Tulane Virus in Model Fluid Foods

IF 4.1 2区 农林科学 Q2 ENVIRONMENTAL SCIENCES
E. Corson, B. Pendyala, A. Patras, D. H. D’Souza
{"title":"Ultraviolet (UV-C) Light Systems for the Inactivation of Feline Calicivirus and Tulane Virus in Model Fluid Foods","authors":"E. Corson,&nbsp;B. Pendyala,&nbsp;A. Patras,&nbsp;D. H. D’Souza","doi":"10.1007/s12560-024-09614-2","DOIUrl":null,"url":null,"abstract":"<div><p>Conventional UV-C (254 nm) inactivation technologies have limitations and potential operator-safety risk. To overcome these disadvantages, novel UV-C light-emitting diodes (LED) are developed and investigated for their performance. This study aimed to determine the inactivation of human norovirus (HuNoV) surrogates, Tulane virus (TV), and feline calicivirus (FCV-F9), by UV-C (254 nm) in comparison to UV-C LED (279 nm) in phosphate-buffered saline (PBS) and coconut water (CW). Five-hundred microliters of FCV-F9 (~ 5 log plaque forming units (PFU)/mL) or TV (~ 6 log PFU/mL) were added to 4.5 mL PBS or CW in continuously stirred glass beakers and exposed to 254 nm UV-C for 0 up to 15 min (maximum dosage of 33.89 mJ/cm<sup>2</sup>) or 279 nm UV-C LED for 0 up to 2.5 min (maximum dosage of 7.03 mJ/cm<sup>2</sup>). Recovered viruses were assayed in duplicate from each treatment replicated thrice. Mixed model analysis of variance was used for data analysis. Significantly lower D<sub>10</sub> values were obtained in PBS and CW (<i>p</i> ≤ 0.05) for both tested viruses using UV-C LED (279 nm) where FCV-F9 showed D<sub>10</sub> values of 7.08 ± 1.75 mJ/cm<sup>2</sup> and 3.75 ± 0.11 mJ/cm<sup>2</sup>, while using UV-C (254 nm) showed D<sub>10</sub> values of 13.81 ± 0.40 mJ/cm<sup>2</sup> and 6.43 ± 0.44 mJ/cm<sup>2</sup> in PBS and CW, respectively. Similarly, lower D<sub>10</sub> values were obtained for TV of 3.91 ± 1.03 mJ/cm<sup>2</sup> and 4.26 ± 1.02 mJ/cm<sup>2</sup> with 279 nm UV-C LED and were 18.76 ± 3.16 mJ/cm<sup>2</sup> and 10.21 ± 1.48 mJ/cm<sup>2</sup> with 254 nm UV-C in PBS and CW, respectively. Viral resistance to these treatments was fluid-matrix dependent. These findings indicate that use of 279 nm UV-C LED is more effective in inactivating HuNoV surrogates than conventional 254 nm UV-C in the tested fluids.</p></div>","PeriodicalId":563,"journal":{"name":"Food and Environmental Virology","volume":"16 4","pages":"506 - 515"},"PeriodicalIF":4.1000,"publicationDate":"2024-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Food and Environmental Virology","FirstCategoryId":"97","ListUrlMain":"https://link.springer.com/article/10.1007/s12560-024-09614-2","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Conventional UV-C (254 nm) inactivation technologies have limitations and potential operator-safety risk. To overcome these disadvantages, novel UV-C light-emitting diodes (LED) are developed and investigated for their performance. This study aimed to determine the inactivation of human norovirus (HuNoV) surrogates, Tulane virus (TV), and feline calicivirus (FCV-F9), by UV-C (254 nm) in comparison to UV-C LED (279 nm) in phosphate-buffered saline (PBS) and coconut water (CW). Five-hundred microliters of FCV-F9 (~ 5 log plaque forming units (PFU)/mL) or TV (~ 6 log PFU/mL) were added to 4.5 mL PBS or CW in continuously stirred glass beakers and exposed to 254 nm UV-C for 0 up to 15 min (maximum dosage of 33.89 mJ/cm2) or 279 nm UV-C LED for 0 up to 2.5 min (maximum dosage of 7.03 mJ/cm2). Recovered viruses were assayed in duplicate from each treatment replicated thrice. Mixed model analysis of variance was used for data analysis. Significantly lower D10 values were obtained in PBS and CW (p ≤ 0.05) for both tested viruses using UV-C LED (279 nm) where FCV-F9 showed D10 values of 7.08 ± 1.75 mJ/cm2 and 3.75 ± 0.11 mJ/cm2, while using UV-C (254 nm) showed D10 values of 13.81 ± 0.40 mJ/cm2 and 6.43 ± 0.44 mJ/cm2 in PBS and CW, respectively. Similarly, lower D10 values were obtained for TV of 3.91 ± 1.03 mJ/cm2 and 4.26 ± 1.02 mJ/cm2 with 279 nm UV-C LED and were 18.76 ± 3.16 mJ/cm2 and 10.21 ± 1.48 mJ/cm2 with 254 nm UV-C in PBS and CW, respectively. Viral resistance to these treatments was fluid-matrix dependent. These findings indicate that use of 279 nm UV-C LED is more effective in inactivating HuNoV surrogates than conventional 254 nm UV-C in the tested fluids.

紫外线 (UV-C) 光系统用于灭活模型流体食品中的猫钙病毒和杜兰病毒。
传统的紫外线-C(254 纳米)灭活技术有其局限性和潜在的操作安全风险。为了克服这些缺点,开发了新型 UV-C 发光二极管 (LED),并对其性能进行了研究。本研究旨在确定紫外线-C(254 纳米)与紫外线-C 发光二极管(279 纳米)在磷酸盐缓冲盐水(PBS)和椰子水(CW)中对人类诺瓦克病毒(HuNoV)代用品、杜兰病毒(TV)和猫犊牛病毒(FCV-F9)的灭活效果比较。将 500 微升 FCV-F9(约 5 log plaque forming units (PFU)/mL )或 TV(约 6 log PFU/mL)加入 4.5 mL 磷酸盐缓冲液或椰子水中,在连续搅拌的玻璃烧杯中,暴露于 254 纳米 UV-C 下 0 至 15 分钟(最大剂量为 33.89 mJ/cm2),或 279 纳米 UV-C LED 下 0 至 2.5 分钟(最大剂量为 7.03 mJ/cm2)。回收的病毒一式两份,每种处理重复三次。数据分析采用混合方差分析模型。使用 UV-C LED (279 nm) 时,两种测试病毒在 PBS 和 CW 中的 D10 值均显著降低(p ≤ 0.05),其中 FCV-F9 的 D10 值分别为 7.08 ± 1.75 mJ/cm2 和 3.75 ± 0.11 mJ/cm2,而使用 UV-C (254 nm) 时,PBS 和 CW 中的 D10 值分别为 13.81 ± 0.40 mJ/cm2 和 6.43 ± 0.44 mJ/cm2。同样,在 279 纳米 UV-C LED 中,TV 的 D10 值较低,分别为 3.91 ± 1.03 mJ/cm2 和 4.26 ± 1.02 mJ/cm2;在 PBS 和 CW 中,254 纳米 UV-C 的 D10 值较低,分别为 18.76 ± 3.16 mJ/cm2 和 10.21 ± 1.48 mJ/cm2。病毒对这些处理方法的耐受性取决于流体基质。这些研究结果表明,在测试液体中使用 279 纳米 UV-C LED 比传统的 254 纳米 UV-C 能更有效地灭活 HuNoV 代用品。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Food and Environmental Virology
Food and Environmental Virology ENVIRONMENTAL SCIENCES-MICROBIOLOGY
CiteScore
6.50
自引率
2.90%
发文量
35
审稿时长
1 months
期刊介绍: Food and Environmental Virology publishes original articles, notes and review articles on any aspect relating to the transmission of pathogenic viruses via the environment (water, air, soil etc.) and foods. This includes epidemiological studies, identification of novel or emerging pathogens, methods of analysis or characterisation, studies on survival and elimination, and development of procedural controls for industrial processes, e.g. HACCP plans. The journal will cover all aspects of this important area, and encompass studies on any human, animal, and plant pathogenic virus which is capable of transmission via the environment or food.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信