Elena Kum, Gordon H Guyatt, Rayid Abdulqawi, Peter Dicpinigaitis, Lieven Dupont, Stephen K Field, Cynthia L French, Peter G Gibson, Richard S Irwin, Faye Johnston, Lorcan McGarvey, Robert Newman, Nada Popovic, Jaclyn A Smith, Woo-Jung Song, Paul M O'Byrne, Imran Satia
{"title":"The McMaster Cough Severity Questionnaire (MCSQ): a cough severity instrument for patients with refractory chronic cough.","authors":"Elena Kum, Gordon H Guyatt, Rayid Abdulqawi, Peter Dicpinigaitis, Lieven Dupont, Stephen K Field, Cynthia L French, Peter G Gibson, Richard S Irwin, Faye Johnston, Lorcan McGarvey, Robert Newman, Nada Popovic, Jaclyn A Smith, Woo-Jung Song, Paul M O'Byrne, Imran Satia","doi":"10.1183/13993003.01565-2024","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Cough severity represents an important endpoint to assess the impact of therapies for patients with refractory chronic cough (RCC).</p><p><strong>Objective: </strong>To develop a new patient-reported outcome measure addressing cough severity in patients with RCC.</p><p><strong>Methods: </strong>Phase 1 (item generation): A systematic survey, focus groups, and expert consultation generated 51 items. Phase 2 (item reduction): From a list of 51 items, 100 patients identified those they had experienced in the previous year and rated their importance on a 5-point scale. The MCSQ included items reported to occur most frequently and that had the highest importance scores. Patient feedback on the MCSQ led to elimination of redundant items. Another 100 patients completed the MCSQ, from which we performed an exploratory factor analysis and a Rasch analysis to further refine items on the MCSQ.</p><p><strong>Results: </strong>Phase 2 led to selection of 15 items from the initial 51. Patient feedback on the 15 items led to elimination of 5 redundant items. An exploratory factor analysis of the 10-item MCSQ led to selection of two domains, elimination of one item that demonstrated cross-loading, and another that had high inter-item correlations. A Rasch analysis of the 8-item MCSQ confirmed that the response options functioned in a logically progressive manner and that no items exhibited differential item functioning. The final 8-item MCSQ has a one-week recall period and includes two domains (intensity and frequency). The 8-item MCSQ had high internal consistency (Cronbach's alpha, 0.89), proved able to distinguish different levels of cough severity (Pearson separation index, 0.89), and demonstrated high cross-sectional convergent validity (Pearson's correlation, 0.76 [95% CI 0.66 to 0.83]) with the 100-mm cough severity visual analogue scale.</p><p><strong>Conclusion: </strong>Initial evidence supports the validity of the MCSQ, an 8-item instrument measuring cough severity in patients with RCC. Future studies should evaluate its properties in measuring change over time.</p>","PeriodicalId":12265,"journal":{"name":"European Respiratory Journal","volume":" ","pages":""},"PeriodicalIF":16.6000,"publicationDate":"2024-11-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Respiratory Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1183/13993003.01565-2024","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Cough severity represents an important endpoint to assess the impact of therapies for patients with refractory chronic cough (RCC).
Objective: To develop a new patient-reported outcome measure addressing cough severity in patients with RCC.
Methods: Phase 1 (item generation): A systematic survey, focus groups, and expert consultation generated 51 items. Phase 2 (item reduction): From a list of 51 items, 100 patients identified those they had experienced in the previous year and rated their importance on a 5-point scale. The MCSQ included items reported to occur most frequently and that had the highest importance scores. Patient feedback on the MCSQ led to elimination of redundant items. Another 100 patients completed the MCSQ, from which we performed an exploratory factor analysis and a Rasch analysis to further refine items on the MCSQ.
Results: Phase 2 led to selection of 15 items from the initial 51. Patient feedback on the 15 items led to elimination of 5 redundant items. An exploratory factor analysis of the 10-item MCSQ led to selection of two domains, elimination of one item that demonstrated cross-loading, and another that had high inter-item correlations. A Rasch analysis of the 8-item MCSQ confirmed that the response options functioned in a logically progressive manner and that no items exhibited differential item functioning. The final 8-item MCSQ has a one-week recall period and includes two domains (intensity and frequency). The 8-item MCSQ had high internal consistency (Cronbach's alpha, 0.89), proved able to distinguish different levels of cough severity (Pearson separation index, 0.89), and demonstrated high cross-sectional convergent validity (Pearson's correlation, 0.76 [95% CI 0.66 to 0.83]) with the 100-mm cough severity visual analogue scale.
Conclusion: Initial evidence supports the validity of the MCSQ, an 8-item instrument measuring cough severity in patients with RCC. Future studies should evaluate its properties in measuring change over time.
期刊介绍:
The European Respiratory Journal (ERJ) is the flagship journal of the European Respiratory Society. It has a current impact factor of 24.9. The journal covers various aspects of adult and paediatric respiratory medicine, including cell biology, epidemiology, immunology, oncology, pathophysiology, imaging, occupational medicine, intensive care, sleep medicine, and thoracic surgery. In addition to original research material, the ERJ publishes editorial commentaries, reviews, short research letters, and correspondence to the editor. The articles are published continuously and collected into 12 monthly issues in two volumes per year.