Vasa vasorum of the no-touch saphenous vein graft observed using frequency-domain optical coherence tomography.

0 CARDIAC & CARDIOVASCULAR SYSTEMS
Akira Sugaya, Satoshi Uesugi, Masayuki Doi, Ryohei Horikoshi, Norihiko Oka, Shuta Imada, Kenji Komiya, Masanori Nakamura, Koji Kawahito
{"title":"Vasa vasorum of the no-touch saphenous vein graft observed using frequency-domain optical coherence tomography.","authors":"Akira Sugaya, Satoshi Uesugi, Masayuki Doi, Ryohei Horikoshi, Norihiko Oka, Shuta Imada, Kenji Komiya, Masanori Nakamura, Koji Kawahito","doi":"10.1093/icvts/ivae167","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>One possible reason for the long-term patency of no-touch (NT) saphenous vein grafts (SVG) is the preservation of the vasa vasorum in the adventitia/perivascular adipose tissue (PAT). We investigated the vasa vasorum of the NT SVG in vivo using frequency-domain optical coherence tomography (FD-OCT), performed qualitative and quantitative analyses and compared them with the conventional SVG.</p><p><strong>Methods: </strong>An FD-OCT study was performed on 14 SVG at the postoperative coronary angiography 1-2 weeks postoperatively (NT group, n = 9; conventional group, n = 5).</p><p><strong>Results: </strong>Many signal-poor tubular lumen structures that can be recognized in the cross-sectional and longitudinal profiles, which indicates the vasa vasorum, were observed in the adventitial/PAT layer in the NT SVG. In contrast, the vasa vasorum were less abundant in the conventional SVG. The volume of vasa vasorum per millimetre of graft in the no-touch group was significantly higher than in the conventional group [0.0020 (0.0017, 0.0043) mm3 and 0.0003 (0.0000, 0.0006) mm3, P = 0.023].</p><p><strong>Conclusions: </strong>FD-OCT showed abundant vasa vasorum in the thick adventitia/PAT layer of NT saphenous veins in vivo. In contrast, few vasa vasorum were observed in the conventional SVG.</p>","PeriodicalId":73406,"journal":{"name":"Interdisciplinary cardiovascular and thoracic surgery","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11495867/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interdisciplinary cardiovascular and thoracic surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/icvts/ivae167","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"0","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: One possible reason for the long-term patency of no-touch (NT) saphenous vein grafts (SVG) is the preservation of the vasa vasorum in the adventitia/perivascular adipose tissue (PAT). We investigated the vasa vasorum of the NT SVG in vivo using frequency-domain optical coherence tomography (FD-OCT), performed qualitative and quantitative analyses and compared them with the conventional SVG.

Methods: An FD-OCT study was performed on 14 SVG at the postoperative coronary angiography 1-2 weeks postoperatively (NT group, n = 9; conventional group, n = 5).

Results: Many signal-poor tubular lumen structures that can be recognized in the cross-sectional and longitudinal profiles, which indicates the vasa vasorum, were observed in the adventitial/PAT layer in the NT SVG. In contrast, the vasa vasorum were less abundant in the conventional SVG. The volume of vasa vasorum per millimetre of graft in the no-touch group was significantly higher than in the conventional group [0.0020 (0.0017, 0.0043) mm3 and 0.0003 (0.0000, 0.0006) mm3, P = 0.023].

Conclusions: FD-OCT showed abundant vasa vasorum in the thick adventitia/PAT layer of NT saphenous veins in vivo. In contrast, few vasa vasorum were observed in the conventional SVG.

利用频域光学相干断层扫描技术观察到的无触摸大隐静脉移植血管。
目的:无触点大隐静脉移植物之所以能长期保持通畅,一个可能的原因是它保留了血管内膜/血管外脂肪组织中的血管。在这项研究中,我们使用频域光学相干断层扫描技术研究了体内无触点大隐静脉移植物的血管,进行了定性和定量分析,并与传统的大隐静脉移植物进行了比较:方法:在术后1-2周进行冠状动脉造影时,对14条隐静脉移植物进行了频域光学相干断层扫描研究(无触摸组,n = 9;传统组,n = 5):结果:在无触碰组的大隐静脉移植物中,可以从横截面和纵向剖面观察到许多信号较弱的管腔结构,这些结构表示血管腔。相比之下,传统大隐静脉移植物中的血管数量较少。无接触组每毫米移植物的血管体积明显高于常规组(0.0020 [0.0017, 0.0043] mm3 和 0.0003 [0.0000, 0.0006] mm3,P = 0.023):结论:频域光学相干断层扫描显示,体内无触点大隐静脉的厚固有层/血管外脂肪组织层中存在大量血管。相比之下,在传统的大隐静脉移植物中很少观察到血管。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信