{"title":"A machine learning based approach to standardizing tooth color and shade recommendations.","authors":"Qijing Li, Du Chen, Hang Wang, Jiefei Shen","doi":"10.1016/j.prosdent.2024.09.010","DOIUrl":null,"url":null,"abstract":"<p><strong>Statement of problem: </strong>Achieving the precise reproduction of tooth color is pivotal in esthetic restorations. However, existing visual and instrumental shade matching methods, each with inherent limitations, have often resulted in inconsistent color communication and subsequently suboptimal esthetic results in clinical practice.</p><p><strong>Purpose: </strong>The purpose of this in vitro study was to evaluate a 2-tier color correction strategy to accurately acquire standardized tooth color and to provide shade recommendations for esthetic restorations.</p><p><strong>Material and methods: </strong>Photographs of a standard color card (ColorChecker Classic; X-rite) and a commercially available shade guide (VITA 3D-Master; Vita Zahnfabrik) were captured under standard lighting conditions. Machine learning (ML) models for color correction, including polynomial regression (PR), backpropagation neural network (BPNN), and extreme learning machine (ELM), were trained using color values extracted from these standardized photographs. Subsequently, photographs made under clinical lighting conditions and featuring both the standard color card and the shade guide underwent the first color correction using the trained ML models. The secondary color correction was then executed based on the custom color space of VITA 3D-Master, yielding corrected color values for shade recommendations. The prediction accuracy of the ML models and the precision of color correction were evaluated using the root mean square error (RMSE), coefficient of determination (R²), and color difference (α=.05 for all statistical analyses).</p><p><strong>Results: </strong>Compared with the PR and BPNN models, the ELM model provided more precise and reliable predictions with the lowest RMSE (2.2) and the highest R<sup>2</sup> (0.996). After 2 rounds of color correction, the color difference was reduced from 7.6 to 1.0, which was lower than the 50:50% acceptability threshold (1.8) and closer to the 50:50% perceptibility threshold (0.8). Furthermore, the matching results between the secondary values and the ground truth of the shade guides achieved an accuracy of 73.1% for shade recommendations.</p><p><strong>Conclusions: </strong>The 2-tier color correction strategy based on the ML models and the color space specified by the VITA 3D-Master system effectively standardized the color of dental photographs and provided a more accurate and stable method of communicating color between dentists and dental laboratory technicians.</p>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2024-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.prosdent.2024.09.010","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Statement of problem: Achieving the precise reproduction of tooth color is pivotal in esthetic restorations. However, existing visual and instrumental shade matching methods, each with inherent limitations, have often resulted in inconsistent color communication and subsequently suboptimal esthetic results in clinical practice.
Purpose: The purpose of this in vitro study was to evaluate a 2-tier color correction strategy to accurately acquire standardized tooth color and to provide shade recommendations for esthetic restorations.
Material and methods: Photographs of a standard color card (ColorChecker Classic; X-rite) and a commercially available shade guide (VITA 3D-Master; Vita Zahnfabrik) were captured under standard lighting conditions. Machine learning (ML) models for color correction, including polynomial regression (PR), backpropagation neural network (BPNN), and extreme learning machine (ELM), were trained using color values extracted from these standardized photographs. Subsequently, photographs made under clinical lighting conditions and featuring both the standard color card and the shade guide underwent the first color correction using the trained ML models. The secondary color correction was then executed based on the custom color space of VITA 3D-Master, yielding corrected color values for shade recommendations. The prediction accuracy of the ML models and the precision of color correction were evaluated using the root mean square error (RMSE), coefficient of determination (R²), and color difference (α=.05 for all statistical analyses).
Results: Compared with the PR and BPNN models, the ELM model provided more precise and reliable predictions with the lowest RMSE (2.2) and the highest R2 (0.996). After 2 rounds of color correction, the color difference was reduced from 7.6 to 1.0, which was lower than the 50:50% acceptability threshold (1.8) and closer to the 50:50% perceptibility threshold (0.8). Furthermore, the matching results between the secondary values and the ground truth of the shade guides achieved an accuracy of 73.1% for shade recommendations.
Conclusions: The 2-tier color correction strategy based on the ML models and the color space specified by the VITA 3D-Master system effectively standardized the color of dental photographs and provided a more accurate and stable method of communicating color between dentists and dental laboratory technicians.
期刊介绍:
The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.