A new method to measure the mechanical properties of rotary endodontic Ni-Ti files: Measurement of 6-axis force/torque and automatic root canal preparation.
{"title":"A new method to measure the mechanical properties of rotary endodontic Ni-Ti files: Measurement of 6-axis force/torque and automatic root canal preparation.","authors":"Hyungwoo Lee, In-Bog Lee","doi":"10.4012/dmj.2024-082","DOIUrl":null,"url":null,"abstract":"<p><p>The purpose of this study was to develop a new instrument to measure the mechanical properties of rotary endodontic Ni-Ti files (ProTaper Gold F2, ProTaper Ultimate F2, and HyFlex EDM Onefile), and to evaluate the overall utility of the device. The instrument was capable of analyzing the 6-axis force/torque generated by the files during cyclic dynamic movement in a metal curved artificial root canal, and doing automatic cyclic dynamic filing in a resin root canal with a preset vertical force limit by adopting a negative feedback mechanism. By analyzing the 6-axis force/torque, we were able to estimate the position and contact points of the files in the curved root canal. ProTaper Gold showed the highest force/torque in all directions. HyFlex EDM had the highest hysteresis ratio, centering ratio value and NCF (number of cycles to fatigue fracture), while the lowest vertical force.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.4012/dmj.2024-082","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
The purpose of this study was to develop a new instrument to measure the mechanical properties of rotary endodontic Ni-Ti files (ProTaper Gold F2, ProTaper Ultimate F2, and HyFlex EDM Onefile), and to evaluate the overall utility of the device. The instrument was capable of analyzing the 6-axis force/torque generated by the files during cyclic dynamic movement in a metal curved artificial root canal, and doing automatic cyclic dynamic filing in a resin root canal with a preset vertical force limit by adopting a negative feedback mechanism. By analyzing the 6-axis force/torque, we were able to estimate the position and contact points of the files in the curved root canal. ProTaper Gold showed the highest force/torque in all directions. HyFlex EDM had the highest hysteresis ratio, centering ratio value and NCF (number of cycles to fatigue fracture), while the lowest vertical force.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.