{"title":"Outcomes of mitral transcatheter edge to edge repair with MitraClip™ – An Indian single center experience","authors":"Sai Satish , Vijayakumar Subban , Yerramareddy Vijayachandra , Abraham Oomman , Ganapathy Arumugam , Hemalatha Senthil , Hema Kethavath , Kamala Devi Pulindram , Saibal Kar , Susheel Kodali , Krishnaswamy Chandrasekaran","doi":"10.1016/j.ihj.2024.09.002","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><div>To evaluate the outcomes of transcatheter edge-to-edge repair (TEER) with MitraClip™ (Abbott Vascular) in symptomatic high surgical risk Indian patients with significant mitral regurgitation (MR).</div></div><div><h3>Methods</h3><div>Patients with moderately severe or severe primary or secondary MR and deemed high surgical risk were treated with MitraClip™. The data were collected retrospectively from medical records. The primary outcome was technical success, and secondary outcomes were ≤2+ MR reduction and improvement in functional capacity at 30 days.</div></div><div><h3>Results</h3><div>Between November 2018 and August 2023, 64 patients were treated with MitraClip<sup>TM</sup>. The mean age was 70.0 ± 12.1 years and 64 % were males. The mean EuroScore II and STS score predicted mortality for mitral valve repair were 5.8 ± 4.5 % and 4.0 ± 3.8 % respectively. MR etiology was primary in 56.3 %, secondary in 40.6 % and mixed in 3.1 %. The device was implanted successfully in all but one patient with technical success rate of 98.4 %. The average number of clips per patient was 1.5 ± 0.6 and 42.2 % patients received more than one clip. The mean mitral valve gradient was 3.5 ± 1.6 mmHg. The MR severity of ≤2+ was achieved in 91.8 % of the subjects and similar proportion were in New York Heart Association Functional Class I or II at 30 days.</div></div><div><h3>Conclusion</h3><div>In high-risk Indian patients with symptomatic significant MR, TEER with MitraClip™ was achieved with a high technical success rate. It was associated with significant reduction in MR severity and improvement in functional capacity in >90 % of the subjects.</div></div>","PeriodicalId":13384,"journal":{"name":"Indian heart journal","volume":"76 5","pages":"Pages 315-320"},"PeriodicalIF":1.4000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian heart journal","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0019483224001822","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Objective
To evaluate the outcomes of transcatheter edge-to-edge repair (TEER) with MitraClip™ (Abbott Vascular) in symptomatic high surgical risk Indian patients with significant mitral regurgitation (MR).
Methods
Patients with moderately severe or severe primary or secondary MR and deemed high surgical risk were treated with MitraClip™. The data were collected retrospectively from medical records. The primary outcome was technical success, and secondary outcomes were ≤2+ MR reduction and improvement in functional capacity at 30 days.
Results
Between November 2018 and August 2023, 64 patients were treated with MitraClipTM. The mean age was 70.0 ± 12.1 years and 64 % were males. The mean EuroScore II and STS score predicted mortality for mitral valve repair were 5.8 ± 4.5 % and 4.0 ± 3.8 % respectively. MR etiology was primary in 56.3 %, secondary in 40.6 % and mixed in 3.1 %. The device was implanted successfully in all but one patient with technical success rate of 98.4 %. The average number of clips per patient was 1.5 ± 0.6 and 42.2 % patients received more than one clip. The mean mitral valve gradient was 3.5 ± 1.6 mmHg. The MR severity of ≤2+ was achieved in 91.8 % of the subjects and similar proportion were in New York Heart Association Functional Class I or II at 30 days.
Conclusion
In high-risk Indian patients with symptomatic significant MR, TEER with MitraClip™ was achieved with a high technical success rate. It was associated with significant reduction in MR severity and improvement in functional capacity in >90 % of the subjects.
期刊介绍:
Indian Heart Journal (IHJ) is the official peer-reviewed open access journal of Cardiological Society of India and accepts articles for publication from across the globe. The journal aims to promote high quality research and serve as a platform for dissemination of scientific information in cardiology with particular focus on South Asia. The journal aims to publish cutting edge research in the field of clinical as well as non-clinical cardiology - including cardiovascular medicine and surgery. Some of the topics covered are Heart Failure, Coronary Artery Disease, Hypertension, Interventional Cardiology, Cardiac Surgery, Valvular Heart Disease, Pulmonary Hypertension and Infective Endocarditis. IHJ open access invites original research articles, research briefs, perspective, case reports, case vignette, cardiovascular images, cardiovascular graphics, research letters, correspondence, reader forum, and interesting photographs, for publication. IHJ open access also publishes theme-based special issues and abstracts of papers presented at the annual conference of the Cardiological Society of India.