Efficacy of Sentinel Cerebral Embolic Protection Device in Transcatheter Aortic Valve Replacement: A Meta-Analysis of Randomized Controlled Trials and Propensity Score-Matched Studies.

IF 2 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Hritvik Jain, Neha Pervez, Debankur Dey, Ramez M Odat, Jyoti Jain, Aman Goyal, Anmol Saggar, Ayham Mohammad Hussein, Aniket Mathur, Sukul Khanna, Raheel Ahmed, Farhan Shahid
{"title":"Efficacy of Sentinel Cerebral Embolic Protection Device in Transcatheter Aortic Valve Replacement: A Meta-Analysis of Randomized Controlled Trials and Propensity Score-Matched Studies.","authors":"Hritvik Jain, Neha Pervez, Debankur Dey, Ramez M Odat, Jyoti Jain, Aman Goyal, Anmol Saggar, Ayham Mohammad Hussein, Aniket Mathur, Sukul Khanna, Raheel Ahmed, Farhan Shahid","doi":"10.1097/CRD.0000000000000797","DOIUrl":null,"url":null,"abstract":"<p><p>Transcatheter aortic valve replacement (TAVR) is frequently associated with stroke due to debris embolization. Although the risk of stroke with newer-generation devices is lower, stroke still represents a significant cause of mortality and morbidity post-TAVR. The Sentinel cerebral embolic protection device (CEPD) is a dual-embolic filter device designed to capture debris dislodged during TAVR. A systematic literature search was performed on the major bibliographic databases to retrieve studies that compared TAVR with and without Sentinel CEPD. Pooled odds ratios (ORs) with 95% confidence intervals (CIs) were calculated using the DerSimonian-Laird random-effects model, with a P value of <0.05 considered statistically significant. This meta-analysis included 6 studies with 25,130 patients undergoing TAVR (12,608: Sentinel CEPD; 12,522: without Sentinel CEPD). The use of the Sentinel CEPD in TAVR was associated with a statistically significant lower risk of acute kidney injury (OR: 0.89; 95% CI: 0.81-0.97; P = 0.01]. The use of Sentinel CEPD in TAVR was associated with a statistically insignificant trend toward a reduction in stroke (OR: 0.80; 95% CI: 0.58-1.10; P = 0.18), all-cause mortality (OR: 0.74; 95% CI: 0.51-1.07; P = 0.11), and major vascular complications (OR: 0.74; 95% CI: 0.46-1.19; P = 0.21). The use of Sentinel CEPD in patients undergoing TAVR does not lead to a statistically significant reduction in stroke, all-cause mortality, or major vascular complications; however, the risk of acute kidney injury is lower. Further randomized studies are warranted to confirm these findings.</p>","PeriodicalId":9549,"journal":{"name":"Cardiology in Review","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2024-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiology in Review","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/CRD.0000000000000797","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Transcatheter aortic valve replacement (TAVR) is frequently associated with stroke due to debris embolization. Although the risk of stroke with newer-generation devices is lower, stroke still represents a significant cause of mortality and morbidity post-TAVR. The Sentinel cerebral embolic protection device (CEPD) is a dual-embolic filter device designed to capture debris dislodged during TAVR. A systematic literature search was performed on the major bibliographic databases to retrieve studies that compared TAVR with and without Sentinel CEPD. Pooled odds ratios (ORs) with 95% confidence intervals (CIs) were calculated using the DerSimonian-Laird random-effects model, with a P value of <0.05 considered statistically significant. This meta-analysis included 6 studies with 25,130 patients undergoing TAVR (12,608: Sentinel CEPD; 12,522: without Sentinel CEPD). The use of the Sentinel CEPD in TAVR was associated with a statistically significant lower risk of acute kidney injury (OR: 0.89; 95% CI: 0.81-0.97; P = 0.01]. The use of Sentinel CEPD in TAVR was associated with a statistically insignificant trend toward a reduction in stroke (OR: 0.80; 95% CI: 0.58-1.10; P = 0.18), all-cause mortality (OR: 0.74; 95% CI: 0.51-1.07; P = 0.11), and major vascular complications (OR: 0.74; 95% CI: 0.46-1.19; P = 0.21). The use of Sentinel CEPD in patients undergoing TAVR does not lead to a statistically significant reduction in stroke, all-cause mortality, or major vascular complications; however, the risk of acute kidney injury is lower. Further randomized studies are warranted to confirm these findings.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Cardiology in Review
Cardiology in Review CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
4.60
自引率
0.00%
发文量
76
审稿时长
>12 weeks
期刊介绍: The mission of Cardiology in Review is to publish reviews on topics of current interest in cardiology that will foster increased understanding of the pathogenesis, diagnosis, clinical course, prevention, and treatment of cardiovascular disorders. Articles of the highest quality are written by authorities in the field and published promptly in a readable format with visual appeal
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信