Diagnostic Value of Ultrasonography in Determination of Knee Joint Pathologies with Comparison to MRI.

Mymensingh medical journal : MMJ Pub Date : 2024-10-01
A Ferdousi, M A Islam, M Begum, M R Debnath, S P Shapla, T Saha, R Biswas, F Ferdouse, M A Rahman
{"title":"Diagnostic Value of Ultrasonography in Determination of Knee Joint Pathologies with Comparison to MRI.","authors":"A Ferdousi, M A Islam, M Begum, M R Debnath, S P Shapla, T Saha, R Biswas, F Ferdouse, M A Rahman","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Knee pain is a common musculoskeletal symptom in the general population and results in significant disability, reducing the quality of life and inducing financial burden to the health care system. This cross-sectional, descriptive type of observational study was conducted with a total 52 patients having symptomatic knee joint disease in the Department of Radiology and Imaging, Mymensingh Medical College Hospital, Bangladesh from April 2019 to September 2020. This study was performed to find out the effectiveness of ultrasonography as a modality of investigation in the determination of knee joint pathologies with comparison to MRI, considering MRI as the gold standard. The majority of the patients 13(25.0%) were in the age group of 15-25 years with mean age was 39.88±15.308 years. In detecting synovial effusion, bursal collection, baker's cyst, tendinopathy and tumor pathologies ultrasound had 100.0% sensitivity, specificity and accuracy for each whether bursitis has 100.0%, 96.4% and 98.07% respectively. MCL tear had 100.0%, 97.8%, 98.07%. LCL tear detection showed 100.0%, 97.8%, 98.07%. PCL tear had 66.7%, 95.9%, 94.2%. ACL tear had 50.0%, 97.6%, 88.4% sensitivity, specificity and accuracy. Meniscal tear showed 66.7%, 97.8%, 88.4% sensitivity and accuracy. In all cases difference was statistically significant with a p value <0.0001 which strongly supported against null hypothesis. From this study, it is concluded that high-resolution USG showed high sensitivity, specificity and accuracy compared to MRI in detecting common knee abnormalities, and could be considered as the first-line imaging modality in the evaluation of knee pain.</p>","PeriodicalId":94148,"journal":{"name":"Mymensingh medical journal : MMJ","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Mymensingh medical journal : MMJ","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Knee pain is a common musculoskeletal symptom in the general population and results in significant disability, reducing the quality of life and inducing financial burden to the health care system. This cross-sectional, descriptive type of observational study was conducted with a total 52 patients having symptomatic knee joint disease in the Department of Radiology and Imaging, Mymensingh Medical College Hospital, Bangladesh from April 2019 to September 2020. This study was performed to find out the effectiveness of ultrasonography as a modality of investigation in the determination of knee joint pathologies with comparison to MRI, considering MRI as the gold standard. The majority of the patients 13(25.0%) were in the age group of 15-25 years with mean age was 39.88±15.308 years. In detecting synovial effusion, bursal collection, baker's cyst, tendinopathy and tumor pathologies ultrasound had 100.0% sensitivity, specificity and accuracy for each whether bursitis has 100.0%, 96.4% and 98.07% respectively. MCL tear had 100.0%, 97.8%, 98.07%. LCL tear detection showed 100.0%, 97.8%, 98.07%. PCL tear had 66.7%, 95.9%, 94.2%. ACL tear had 50.0%, 97.6%, 88.4% sensitivity, specificity and accuracy. Meniscal tear showed 66.7%, 97.8%, 88.4% sensitivity and accuracy. In all cases difference was statistically significant with a p value <0.0001 which strongly supported against null hypothesis. From this study, it is concluded that high-resolution USG showed high sensitivity, specificity and accuracy compared to MRI in detecting common knee abnormalities, and could be considered as the first-line imaging modality in the evaluation of knee pain.

超声波与核磁共振成像在确定膝关节病变方面的诊断价值比较。
膝关节疼痛是普通人群中常见的肌肉骨骼症状,会导致严重残疾,降低生活质量,并给医疗系统带来经济负担。这项横断面、描述性观察研究于 2019 年 4 月至 2020 年 9 月在孟加拉国迈门辛医学院医院放射学和影像学系对 52 名有症状的膝关节疾病患者进行了研究。这项研究旨在了解超声波检查作为一种检查方式,与核磁共振成像相比,在确定膝关节病变方面的有效性,并将核磁共振成像视为金标准。大部分患者年龄在 15-25 岁之间,其中 13 人(25.0%)的平均年龄为(39.88±15.308)岁。在检测滑膜积液、滑囊积液、贝克氏囊肿、肌腱病和肿瘤病变方面,超声波的敏感性、特异性和准确性均为 100.0%,而滑囊炎的敏感性、特异性和准确性分别为 100.0%、96.4% 和 98.07%。MCL撕裂的敏感性、特异性和准确性分别为 100.0%、97.8% 和 98.07%。LCL撕裂的检测率分别为100.0%、97.8%和98.07%。PCL 撕裂的检测率分别为 66.7%、95.9% 和 94.2%。前交叉韧带撕裂的敏感性、特异性和准确性分别为50.0%、97.6%和88.4%。半月板撕裂的敏感性和准确性分别为 66.7%、97.8% 和 88.4%。所有病例的差异均有统计学意义,P 值为
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信