Real-time non-destructive monitoring of supported liquid membranes using electrochemical impedance spectroscopy

IF 8.4 1区 工程技术 Q1 ENGINEERING, CHEMICAL
Hiroki Fukuda, Jongho Lee
{"title":"Real-time non-destructive monitoring of supported liquid membranes using electrochemical impedance spectroscopy","authors":"Hiroki Fukuda,&nbsp;Jongho Lee","doi":"10.1016/j.memsci.2024.123360","DOIUrl":null,"url":null,"abstract":"<div><div>The degradation of supported liquid membranes (SLMs) due to membrane liquid leaching has been a hurdle for their implementation in resource recovery from waste streams. We present a novel approach utilizing four-electrode mode electrochemical impedance spectroscopy (EIS) for real-time, non-destructive monitoring of SLM degradation, providing detailed analysis of SLM's structural changes. We first showed that SLMs may be depicted as an electrical circuit of resistors and capacitors by EIS. The EIS then revealed that SLM degradation progressed over four different phases as a result of varying rates of thickness and area reduction of the SLM. To demonstrate the effectiveness of EIS-based diagnosis, we prepared SLMs designed for selective medium-chain fatty acid (MCFA) extraction in intact, partially, and completely degraded states, determined by the EIS. The intact SLM showed a high selectivity (∼50) for MCFAs over short-chain fatty acids. The selectivity decreased to ∼22 in the partially degraded SLMs, and less than 1 in the completely degraded SLM, indicating the clear linkage between the degree of degradation and the separation performance. Our four-electrode mode EIS method is expected to serve as a key tool for efficient SLM operation and stable SLM development.</div></div>","PeriodicalId":368,"journal":{"name":"Journal of Membrane Science","volume":"713 ","pages":"Article 123360"},"PeriodicalIF":8.4000,"publicationDate":"2024-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Membrane Science","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0376738824009542","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, CHEMICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The degradation of supported liquid membranes (SLMs) due to membrane liquid leaching has been a hurdle for their implementation in resource recovery from waste streams. We present a novel approach utilizing four-electrode mode electrochemical impedance spectroscopy (EIS) for real-time, non-destructive monitoring of SLM degradation, providing detailed analysis of SLM's structural changes. We first showed that SLMs may be depicted as an electrical circuit of resistors and capacitors by EIS. The EIS then revealed that SLM degradation progressed over four different phases as a result of varying rates of thickness and area reduction of the SLM. To demonstrate the effectiveness of EIS-based diagnosis, we prepared SLMs designed for selective medium-chain fatty acid (MCFA) extraction in intact, partially, and completely degraded states, determined by the EIS. The intact SLM showed a high selectivity (∼50) for MCFAs over short-chain fatty acids. The selectivity decreased to ∼22 in the partially degraded SLMs, and less than 1 in the completely degraded SLM, indicating the clear linkage between the degree of degradation and the separation performance. Our four-electrode mode EIS method is expected to serve as a key tool for efficient SLM operation and stable SLM development.

Abstract Image

利用电化学阻抗谱对支撑液体膜进行实时无损监测
膜液浸出导致的支撑液体膜(SLMs)降解一直是其从废物流中进行资源回收的障碍。我们提出了一种新方法,利用四电极模式电化学阻抗光谱(EIS)对 SLM 降解进行实时、无损监测,提供 SLM 结构变化的详细分析。我们首先通过 EIS 发现 SLM 可被描述为电阻器和电容器组成的电路。然后,通过 EIS 发现,由于 SLM 的厚度和面积减小的速度不同,SLM 退化经历了四个不同的阶段。为了证明基于 EIS 诊断的有效性,我们制备了用于选择性提取中链脂肪酸 (MCFA) 的 SLM,并通过 EIS 确定了其完整、部分和完全降解的状态。与短链脂肪酸相比,完整的 SLM 对 MCFA 具有较高的选择性(50 ∼ 50)。在部分降解的 SLM 中,选择性降至 ∼22,而在完全降解的 SLM 中,选择性低于 1,这表明降解程度与分离性能之间存在明显的联系。我们的四电极模式 EIS 方法有望成为高效 SLM 运行和稳定 SLM 开发的关键工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Membrane Science
Journal of Membrane Science 工程技术-高分子科学
CiteScore
17.10
自引率
17.90%
发文量
1031
审稿时长
2.5 months
期刊介绍: The Journal of Membrane Science is a publication that focuses on membrane systems and is aimed at academic and industrial chemists, chemical engineers, materials scientists, and membranologists. It publishes original research and reviews on various aspects of membrane transport, membrane formation/structure, fouling, module/process design, and processes/applications. The journal primarily focuses on the structure, function, and performance of non-biological membranes but also includes papers that relate to biological membranes. The Journal of Membrane Science publishes Full Text Papers, State-of-the-Art Reviews, Letters to the Editor, and Perspectives.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信