Pathological Variables and Laboratory Values in Infants with Neonatal Cholestasis Showing Nonexcretion on Tc-99m Mebrofenin Hepatobiliary Scans: A Descriptive Study.

IF 0.4 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Indian Journal of Nuclear Medicine Pub Date : 2024-05-01 Epub Date: 2024-08-17 DOI:10.4103/ijnm.ijnm_127_23
Ahalya Nair, Madhusudhanan Ponnusamy
{"title":"Pathological Variables and Laboratory Values in Infants with Neonatal Cholestasis Showing Nonexcretion on Tc-99m Mebrofenin Hepatobiliary Scans: A Descriptive Study.","authors":"Ahalya Nair, Madhusudhanan Ponnusamy","doi":"10.4103/ijnm.ijnm_127_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Cholescintigraphy using Tc-99m Mebrofenin is routinely performed as an initial diagnostic test in infants with neonatal cholestasis suspected of having biliary atresia. Demonstration of drainage of bile into the small intestine indicates patency of the biliary tract and thus rules out biliary atresia. Non-excretion of tracer into the small intestine, however, can be caused by obstructive as well as non-obstructive conditions, and it is known that false-positive findings are found with the use of Tc-99m Mebrofenin scintigraphy.</p><p><strong>Aim: </strong>In the present study, we retrospectively calculated the proportion of infants eventually diagnosed to have biliary atresia that were initially ruled to have a non-excreting cholescintigraphy pattern in our institution. We have also attempted a systematic description of the cardinal histological characteristics, haematological and hepatic biochemical variables in infants with non-excreting patterns.</p><p><strong>Materials and methods: </strong>This retrospective, descriptive study was conducted in Jawaharlal Institute of Postgraduate Medical Education and Research (JIPMER), Puducherry. We reviewed data from infants who underwent cholescintigraphy with Tc-99m Mebrofenin between January 2016 through June 2022. We included infants in whom the scan was ruled \"non-excreting\" i.e. those infants in whom biliary atresia could not be ruled out based on the results of the scan. The difference in mean for haematological parameters and ALP were compared between the two groups i.e., biliary atresia versus other than biliary atresia by using Independent student's t-test; the remaining liver biochemical parameters were compared by using Mann-Whitney U Test and a p value < 0.05 was considered to be statistically significant.</p><p><strong>Results: </strong>A non-excretory pattern on cholescintigraphy was found to be due to biliary atresia in 49% of cases (as confirmed by exploratory surgery) and an additional 19.6 % of cases by trucut biopsy (total 68.6%). The difference in the mean serum GGT levels was found to be statistically significant (<0.001).</p><p><strong>Conclusion: </strong>A non-draining pattern on cholescintigraphy is caused by biliary atresia in the greater percentage of cases presenting with cholestasis. The difference in mean GGT levels was found to be statistically significant between biliary atresia and other causes of non-draining patterns on cholescintigraphy.</p>","PeriodicalId":45830,"journal":{"name":"Indian Journal of Nuclear Medicine","volume":"39 3","pages":"163-169"},"PeriodicalIF":0.4000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11404738/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Nuclear Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/ijnm.ijnm_127_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/17 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Cholescintigraphy using Tc-99m Mebrofenin is routinely performed as an initial diagnostic test in infants with neonatal cholestasis suspected of having biliary atresia. Demonstration of drainage of bile into the small intestine indicates patency of the biliary tract and thus rules out biliary atresia. Non-excretion of tracer into the small intestine, however, can be caused by obstructive as well as non-obstructive conditions, and it is known that false-positive findings are found with the use of Tc-99m Mebrofenin scintigraphy.

Aim: In the present study, we retrospectively calculated the proportion of infants eventually diagnosed to have biliary atresia that were initially ruled to have a non-excreting cholescintigraphy pattern in our institution. We have also attempted a systematic description of the cardinal histological characteristics, haematological and hepatic biochemical variables in infants with non-excreting patterns.

Materials and methods: This retrospective, descriptive study was conducted in Jawaharlal Institute of Postgraduate Medical Education and Research (JIPMER), Puducherry. We reviewed data from infants who underwent cholescintigraphy with Tc-99m Mebrofenin between January 2016 through June 2022. We included infants in whom the scan was ruled "non-excreting" i.e. those infants in whom biliary atresia could not be ruled out based on the results of the scan. The difference in mean for haematological parameters and ALP were compared between the two groups i.e., biliary atresia versus other than biliary atresia by using Independent student's t-test; the remaining liver biochemical parameters were compared by using Mann-Whitney U Test and a p value < 0.05 was considered to be statistically significant.

Results: A non-excretory pattern on cholescintigraphy was found to be due to biliary atresia in 49% of cases (as confirmed by exploratory surgery) and an additional 19.6 % of cases by trucut biopsy (total 68.6%). The difference in the mean serum GGT levels was found to be statistically significant (<0.001).

Conclusion: A non-draining pattern on cholescintigraphy is caused by biliary atresia in the greater percentage of cases presenting with cholestasis. The difference in mean GGT levels was found to be statistically significant between biliary atresia and other causes of non-draining patterns on cholescintigraphy.

新生儿胆汁淤积症婴儿 Tc-99m 甲钴胺肝胆扫描无排泄的病理变量和实验室值:描述性研究。
导言:胆囊造影(Cholcintigraphy)使用锝-99m甲勃罗宁(Tc-99m Mebrofenin),是新生儿胆汁淤积症疑似胆道闭锁婴儿的常规初步诊断检查。显示胆汁排入小肠表明胆道通畅,从而排除胆道闭锁。目的:在本研究中,我们回顾性地计算了在我院最终被诊断为胆道闭锁的婴儿中,最初被判定为不分泌胆汁的婴儿所占的比例。我们还试图系统地描述无胆汁分泌型婴儿的主要组织学特征、血液学和肝脏生化变量:这项回顾性、描述性研究在普度切里贾瓦哈拉尔研究生医学教育与研究院(JIPMER)进行。我们回顾了在 2016 年 1 月至 2022 年 6 月期间接受 Tc-99m 甲卟吩胆囊造影的婴儿的数据。我们纳入了扫描结果为 "无分泌 "的婴儿,即根据扫描结果无法排除胆道闭锁的婴儿。采用独立学生 t 检验比较两组(即胆道闭锁与非胆道闭锁)之间血液学参数和 ALP 平均值的差异;采用 Mann-Whitney U 检验比较其余肝脏生化参数,P 值小于 0.05 视为具有统计学意义:49%的病例(经探查性手术证实)胆道造影显示为非分泌型,另有19.6%的病例(总计68.6%)经穿刺活检证实为胆道闭锁。血清谷丙转氨酶平均水平的差异具有统计学意义(结论:在胆汁淤积的大部分病例中,胆道造影显示的非排水模式是由胆道闭锁引起的。研究发现,胆道闭锁和其他原因导致的胆道造影不排空模式的平均血清 GGT 水平差异具有统计学意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Indian Journal of Nuclear Medicine
Indian Journal of Nuclear Medicine RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
0.70
自引率
0.00%
发文量
46
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信