Comparing methods for detection of gastro-oesophageal reflux in anaesthetized dogs.

IF 1.4 2区 农林科学 Q2 VETERINARY SCIENCES
Christiaan J Blignaut, Abdur R Kadwa, Etienne P Basson, Gareth E Zeiler
{"title":"Comparing methods for detection of gastro-oesophageal reflux in anaesthetized dogs.","authors":"Christiaan J Blignaut, Abdur R Kadwa, Etienne P Basson, Gareth E Zeiler","doi":"10.1016/j.vaa.2024.08.002","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To compare the sensitivity and specificity of pH with multichannel intraluminal impedance (pH-MII), pH-metry (pH) alone and MII alone to direct observation of GOR by endoscopy in anaesthetized dogs.</p><p><strong>Study design: </strong>A prospective comparative trial in a live canine model.</p><p><strong>Animals: </strong>A group of 35 (22 females, 13 males) dogs of various breeds. The mean (range) body weight and age were 31.9 (14-40) kg and 5.6 (0.75-12) years, respectively.</p><p><strong>Methods: </strong>All dogs were premedicated with medetomidine and morphine, anaesthesia was induced with propofol and maintained on isoflurane in oxygen. A monitoring assembly consisting of an endoscopy camera, endotracheal tube and a disposable flexible pH-MII catheter was used to measure oesophageal pH, MII and directly visualize reflux. Visual reflux score was (0-3) and pH was recorded on a data capture sheet. Reflux was considered to have occurred whenever oesophageal pH was < 4.0 or > 7.5, device software analysing MII data detected fluid or a visual reflux score of 2 or 3 were assigned. Receiver operator curves (ROC) analysis was used to determine sensitivity and specificity for each monitoring method to detect GOR.</p><p><strong>Results: </strong>Endoscopy identified GOR in 20 dogs (57%), pH-MII in 19 dogs (54%), pH alone in 13 dogs (37%) and MII alone in 12 dogs (24%). ROC analysis showed fair accuracy for pH-MII and pH alone, whereas MII demonstrated low accuracy.</p><p><strong>Conclusions and clinical relevance: </strong>In conclusion, pH-MII is a reliable method for detecting GOR and emerges as a promising tool for future research. Endoscopy is reliable and provides the ability to subjectively quantify the volume of reflux; however, it lacks the ability to discern the pH of refluxate. pH alone misses reflux events with intermediate pH (4.1-7.4). Incorporation of impedance addresses some of the limitations associated with pH alone and enhances diagnostic accuracy.</p>","PeriodicalId":23626,"journal":{"name":"Veterinary anaesthesia and analgesia","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-08-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary anaesthesia and analgesia","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1016/j.vaa.2024.08.002","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To compare the sensitivity and specificity of pH with multichannel intraluminal impedance (pH-MII), pH-metry (pH) alone and MII alone to direct observation of GOR by endoscopy in anaesthetized dogs.

Study design: A prospective comparative trial in a live canine model.

Animals: A group of 35 (22 females, 13 males) dogs of various breeds. The mean (range) body weight and age were 31.9 (14-40) kg and 5.6 (0.75-12) years, respectively.

Methods: All dogs were premedicated with medetomidine and morphine, anaesthesia was induced with propofol and maintained on isoflurane in oxygen. A monitoring assembly consisting of an endoscopy camera, endotracheal tube and a disposable flexible pH-MII catheter was used to measure oesophageal pH, MII and directly visualize reflux. Visual reflux score was (0-3) and pH was recorded on a data capture sheet. Reflux was considered to have occurred whenever oesophageal pH was < 4.0 or > 7.5, device software analysing MII data detected fluid or a visual reflux score of 2 or 3 were assigned. Receiver operator curves (ROC) analysis was used to determine sensitivity and specificity for each monitoring method to detect GOR.

Results: Endoscopy identified GOR in 20 dogs (57%), pH-MII in 19 dogs (54%), pH alone in 13 dogs (37%) and MII alone in 12 dogs (24%). ROC analysis showed fair accuracy for pH-MII and pH alone, whereas MII demonstrated low accuracy.

Conclusions and clinical relevance: In conclusion, pH-MII is a reliable method for detecting GOR and emerges as a promising tool for future research. Endoscopy is reliable and provides the ability to subjectively quantify the volume of reflux; however, it lacks the ability to discern the pH of refluxate. pH alone misses reflux events with intermediate pH (4.1-7.4). Incorporation of impedance addresses some of the limitations associated with pH alone and enhances diagnostic accuracy.

比较检测麻醉犬胃食管反流的方法。
目的比较pH值与多通道腔内阻抗(pH-MII)、单纯pH值测量(pH)和单纯MII与麻醉犬内镜直接观察GOR的敏感性和特异性:研究设计:在活体犬模型中进行前瞻性比较试验:动物:35只不同品种的狗(22只雌性,13只雄性)。平均体重(范围)和年龄分别为 31.9(14-40)公斤和 5.6(0.75-12)岁:所有犬只均使用美托咪定和吗啡进行预麻醉,使用异丙酚诱导麻醉,并在氧气中使用异氟醚维持麻醉。使用由内窥镜摄像机、气管插管和一次性柔性 pH-MII 导管组成的监测装置测量食道 pH 值、MII 值并直接观察反流情况。视觉反流评分为(0-3),pH 值记录在数据采集表上。当食道 pH 值小于 4.0 或大于 7.5、分析 MII 数据的设备软件检测到液体或视觉反流评分为 2 或 3 时,即认为发生了反流。采用受体操作者曲线(ROC)分析法确定每种监测方法检测 GOR 的灵敏度和特异性:结果:20 只狗(57%)通过内窥镜检查发现了 GOR,19 只狗(54%)通过 pH-MII 检查发现了 GOR,13 只狗(37%)仅通过 pH 检查发现了 GOR,12 只狗(24%)仅通过 MII 检查发现了 GOR。ROC 分析表明,pH-MII 和单纯 pH 的准确性尚可,而 MII 的准确性较低:总之,pH-MII 是检测 GOR 的一种可靠方法,是未来研究的一种有前途的工具。内窥镜检查是可靠的,能够主观量化反流物的体积;但它缺乏辨别反流物 pH 值的能力。阻抗的加入解决了单用 pH 值的一些局限性,并提高了诊断的准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Veterinary anaesthesia and analgesia
Veterinary anaesthesia and analgesia 农林科学-兽医学
CiteScore
3.10
自引率
17.60%
发文量
91
审稿时长
97 days
期刊介绍: Veterinary Anaesthesia and Analgesia is the official journal of the Association of Veterinary Anaesthetists, the American College of Veterinary Anesthesia and Analgesia and the European College of Veterinary Anaesthesia and Analgesia. Its purpose is the publication of original, peer reviewed articles covering all branches of anaesthesia and the relief of pain in animals. Articles concerned with the following subjects related to anaesthesia and analgesia are also welcome: the basic sciences; pathophysiology of disease as it relates to anaesthetic management equipment intensive care chemical restraint of animals including laboratory animals, wildlife and exotic animals welfare issues associated with pain and distress education in veterinary anaesthesia and analgesia. Review articles, special articles, and historical notes will also be published, along with editorials, case reports in the form of letters to the editor, and book reviews. There is also an active correspondence section.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信