Comparison of Antigen Retrieval Methods for Immunohistochemical Analysis of Cartilage Matrix Glycoproteins Using Cartilage Intermediate Layer Protein 2 (CILP-2) as an Example.

IF 2.3 Q3 BIOCHEMICAL RESEARCH METHODS
Taavi Torga, Siim Suutre, Kalle Kisand, Marina Aunapuu, Andres Arend
{"title":"Comparison of Antigen Retrieval Methods for Immunohistochemical Analysis of Cartilage Matrix Glycoproteins Using Cartilage Intermediate Layer Protein 2 (CILP-2) as an Example.","authors":"Taavi Torga, Siim Suutre, Kalle Kisand, Marina Aunapuu, Andres Arend","doi":"10.3390/mps7050067","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this study was to compare different antigen retrieval methods to improve the outcome of immunohistochemistry (IHC) performed on osteoarthritic (OA) cartilage obtained from total knee replacement operation. A voluminous and dense extracellular matrix of articular cartilage inhibits antibody penetration, and therefore, proteins present at low concentrations and masked during fixation may need antigen retrieval to enhance an IHC outcome. We focused on the IHC detection of a minor but diagnostically promising cartilage glycoprotein, CILP-2 (cartilage intermediate layer protein 2), to demonstrate the effect of four different protocols: (1) heat-induced epitope retrieval (HIER), (2) proteolytic-induced epitope retrieval applying proteinase K and hyaluronidase (PIER), (3) HIER combined with PIER, and (4) no antigen retrieval (control). A semi-quantitative staining assessment based on the CILP-2 staining extent was applied. Out of the tested antigen retrieval protocols, the best CILP-2 IHC staining results were achieved by PIER. Combining PIER with HIER did not improve CILP-2 staining in the given experimental setting. Rather the opposite, the application of heat reduced the positive effect of PIER on CILP-2 staining and resulted in the frequent detachment of sections from the slides. Our findings emphasize the need for proper adaptation of antigen retrieval protocols for IHC to maximize the quantitative evaluation of minor matrix proteins in OA articular cartilage samples.</p>","PeriodicalId":18715,"journal":{"name":"Methods and Protocols","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2024-08-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11417793/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Methods and Protocols","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/mps7050067","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

The aim of this study was to compare different antigen retrieval methods to improve the outcome of immunohistochemistry (IHC) performed on osteoarthritic (OA) cartilage obtained from total knee replacement operation. A voluminous and dense extracellular matrix of articular cartilage inhibits antibody penetration, and therefore, proteins present at low concentrations and masked during fixation may need antigen retrieval to enhance an IHC outcome. We focused on the IHC detection of a minor but diagnostically promising cartilage glycoprotein, CILP-2 (cartilage intermediate layer protein 2), to demonstrate the effect of four different protocols: (1) heat-induced epitope retrieval (HIER), (2) proteolytic-induced epitope retrieval applying proteinase K and hyaluronidase (PIER), (3) HIER combined with PIER, and (4) no antigen retrieval (control). A semi-quantitative staining assessment based on the CILP-2 staining extent was applied. Out of the tested antigen retrieval protocols, the best CILP-2 IHC staining results were achieved by PIER. Combining PIER with HIER did not improve CILP-2 staining in the given experimental setting. Rather the opposite, the application of heat reduced the positive effect of PIER on CILP-2 staining and resulted in the frequent detachment of sections from the slides. Our findings emphasize the need for proper adaptation of antigen retrieval protocols for IHC to maximize the quantitative evaluation of minor matrix proteins in OA articular cartilage samples.

以软骨中间层蛋白 2 (CILP-2) 为例,比较用于软骨基质糖蛋白免疫组化分析的抗原检索方法。
本研究旨在比较不同的抗原回收方法,以改善对全膝关节置换手术中获得的骨关节炎(OA)软骨进行免疫组化(IHC)的结果。关节软骨的细胞外基质体积大、密度高,抑制了抗体的穿透,因此,在固定过程中被掩盖的低浓度蛋白质可能需要抗原回收来提高 IHC 结果。我们重点研究了软骨糖蛋白 CILP-2(软骨中间层蛋白 2)的 IHC 检测,并展示了四种不同方案的效果:(1)热诱导表位检索(HIER);(2)蛋白水解诱导表位检索,应用蛋白酶 K 和透明质酸酶(PIER);(3)HIER 与 PIER 结合;(4)无抗原检索(对照)。根据 CILP-2 染色程度进行半定量染色评估。在测试的抗原回收方案中,PIER 的 CILP-2 IHC 染色效果最好。在特定的实验环境中,将 PIER 与 HIER 结合使用并不能改善 CILP-2 染色效果。相反,加热降低了 PIER 对 CILP-2 染色的积极作用,并导致切片频繁从载玻片上脱落。我们的研究结果表明,需要适当调整 IHC 抗原回收方案,以最大限度地定量评估 OA 关节软骨样本中的次要基质蛋白。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Methods and Protocols
Methods and Protocols Biochemistry, Genetics and Molecular Biology-Biochemistry, Genetics and Molecular Biology (miscellaneous)
CiteScore
3.60
自引率
0.00%
发文量
85
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信