FreeClimb 88 catheter with Tenzing 8 delivery for contact aspiration mechanical thrombectomy of anterior circulation large vessel occlusions.

IF 1.7 4区 医学 Q3 Medicine
Matthew D Alexander, James Caldwell, Shane Sh Lee, Warren T Kim, Joey D English, Jaehyun Kim, Ben J McGuinness, Matthew Page, Nebiyat F Belachew, Jonathan A Grossberg, Daniel Tonetti, Jane Khalife, Hamza Shaikh, Omar Kass-Hout, Marco Colasurdo, Ryan Priest, Bahram Varjavand, Rajkamal S Khangura, Thymur A Chaudhry, Fabio Settecase
{"title":"FreeClimb 88 catheter with Tenzing 8 delivery for contact aspiration mechanical thrombectomy of anterior circulation large vessel occlusions.","authors":"Matthew D Alexander, James Caldwell, Shane Sh Lee, Warren T Kim, Joey D English, Jaehyun Kim, Ben J McGuinness, Matthew Page, Nebiyat F Belachew, Jonathan A Grossberg, Daniel Tonetti, Jane Khalife, Hamza Shaikh, Omar Kass-Hout, Marco Colasurdo, Ryan Priest, Bahram Varjavand, Rajkamal S Khangura, Thymur A Chaudhry, Fabio Settecase","doi":"10.1177/15910199241284792","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Contact aspiration mechanical thrombectomy (CAMT) with 0.088-inch catheters may improve first-pass success rates, but delivery of such catheters can be challenging and limit effectiveness. This study examines the initial multicenter experience using the FreeClimb 88 catheter paired with the Tenzing 8 delivery catheter.</p><p><strong>Materials and methods: </strong>Retrospective analysis was performed of consecutive patients with large vessel occlusion (LVO) of the internal carotid artery (ICA) or M1 segment of the middle cerebral artery treated with off-label CAMT using the FreeClimb 88 and Tenzing 8 at eight sites participating in the early limited release for these devices. Demographic and procedural variables were collected and analyzed with descriptive statistics and multivariable analysis.</p><p><strong>Results: </strong>Fifty-three consecutive patients were treated. Large vessel occlusion was located in the ICA in 19/53 (35.8%) patients; 34/53 (64.2%) were in the M1 segment. FreeClimb 88 was successfully delivered to the site of occlusion in 50/53 (94.3%) of patients. First-pass TICI 2c or 3 was achieved with FreeClimb 88 delivered by Tenzing 8 in 36 (67.9%) cases. Among cases with successful FreeClimb 88 delivery 9/50 (18.0%) required additional smaller devices to perform thrombectomy of distal occlusions after recanalization of the initial LVO. No complications or symptomatic hemorrhages occurred following thrombectomy.</p><p><strong>Conclusion: </strong>Contact aspiration mechanical thrombectomy performed for ICA or M1 LVOs using FreeClimb 88 delivered with Tenzing 8 was safe, effective, and efficient in this early experience, with first-pass TICI 2c or 3 was achieved in 68% of patients without procedural complications occurring in any cases.</p>","PeriodicalId":14380,"journal":{"name":"Interventional Neuroradiology","volume":" ","pages":"15910199241284792"},"PeriodicalIF":1.7000,"publicationDate":"2024-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional Neuroradiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15910199241284792","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Contact aspiration mechanical thrombectomy (CAMT) with 0.088-inch catheters may improve first-pass success rates, but delivery of such catheters can be challenging and limit effectiveness. This study examines the initial multicenter experience using the FreeClimb 88 catheter paired with the Tenzing 8 delivery catheter.

Materials and methods: Retrospective analysis was performed of consecutive patients with large vessel occlusion (LVO) of the internal carotid artery (ICA) or M1 segment of the middle cerebral artery treated with off-label CAMT using the FreeClimb 88 and Tenzing 8 at eight sites participating in the early limited release for these devices. Demographic and procedural variables were collected and analyzed with descriptive statistics and multivariable analysis.

Results: Fifty-three consecutive patients were treated. Large vessel occlusion was located in the ICA in 19/53 (35.8%) patients; 34/53 (64.2%) were in the M1 segment. FreeClimb 88 was successfully delivered to the site of occlusion in 50/53 (94.3%) of patients. First-pass TICI 2c or 3 was achieved with FreeClimb 88 delivered by Tenzing 8 in 36 (67.9%) cases. Among cases with successful FreeClimb 88 delivery 9/50 (18.0%) required additional smaller devices to perform thrombectomy of distal occlusions after recanalization of the initial LVO. No complications or symptomatic hemorrhages occurred following thrombectomy.

Conclusion: Contact aspiration mechanical thrombectomy performed for ICA or M1 LVOs using FreeClimb 88 delivered with Tenzing 8 was safe, effective, and efficient in this early experience, with first-pass TICI 2c or 3 was achieved in 68% of patients without procedural complications occurring in any cases.

FreeClimb 88 导管配有 Tenzing 8 输送装置,用于前循环大血管闭塞的接触式抽吸机械血栓切除术。
目的:使用 0.088 英寸导管进行接触式抽吸机械血栓切除术(CAMT)可提高首次成功率,但这种导管的输送可能具有挑战性,并限制了有效性。本研究探讨了使用 FreeClimb 88 导管和 Tenzing 8 输送导管的初步多中心经验:回顾性分析了在 8 个参与早期有限放行这些设备的医疗机构使用 FreeClimb 88 和 Tenzing 8 进行标签外 CAMT 治疗的颈内动脉 (ICA) 或大脑中动脉 M1 段大血管闭塞 (LVO) 连续患者的情况。研究人员收集了人口统计学和手术变量,并进行了描述性统计和多变量分析:连续治疗了 53 例患者。19/53(35.8%)例患者的大血管闭塞位于ICA;34/53(64.2%)例患者的大血管闭塞位于M1段。有 50/53 名患者(94.3%)成功将 FreeClimb 88 送至闭塞部位。有 36 例(67.9%)患者通过 Tenzing 8 FreeClimb 88 实现了首次 TICI 2c 或 3。在成功使用 FreeClimb 88 的病例中,9/50(18.0%)的患者在对最初的 LVO 进行再通之后,需要使用其他更小的设备对远端闭塞进行血栓切除。血栓切除术后未出现并发症或症状性出血:结论:使用FreeClimb 88和Tenzing 8对ICA或M1 LVO进行接触抽吸式机械血栓切除术是安全、有效和高效的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.80
自引率
11.80%
发文量
192
审稿时长
6-12 weeks
期刊介绍: Interventional Neuroradiology (INR) is a peer-reviewed clinical practice journal documenting the current state of interventional neuroradiology worldwide. INR publishes original clinical observations, descriptions of new techniques or procedures, case reports, and articles on the ethical and social aspects of related health care. Original research published in INR is related to the practice of interventional neuroradiology...
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信