Achieving precise dual detection: One-tube reverse transcription-recombinase aided amplification (RT-RAA) combined with lateral flow strip (LFS) assay for RNA and DNA target genes from pepper mild mottle virus and Colletotrichum species in crude plant samples.
Yuhao Cao, Dankan Yan, Huijie Zhou, Kelei Han, Qionglian Wan, Jiejun Peng, Hongying Zheng, Lin Lin, Fei Yan, Xuemei Song
{"title":"Achieving precise dual detection: One-tube reverse transcription-recombinase aided amplification (RT-RAA) combined with lateral flow strip (LFS) assay for RNA and DNA target genes from pepper mild mottle virus and Colletotrichum species in crude plant samples.","authors":"Yuhao Cao, Dankan Yan, Huijie Zhou, Kelei Han, Qionglian Wan, Jiejun Peng, Hongying Zheng, Lin Lin, Fei Yan, Xuemei Song","doi":"10.1016/j.talanta.2024.126908","DOIUrl":null,"url":null,"abstract":"<p><p>Ensuring the detection sensitivity of both RNA-derived and DNA-derived target genes in a single reaction has posed a significant challenge for on-site detection of plant pathogens. This challenge was addressed by developing a one-tube dual RT-RAA assay combined with LFS for the rapid on-site detection of pepper mild mottle virus (PMMoV) and four Colletotrichum species causing anthracnose in Solanaceous crops. By testing four different combinations of primer groups, two combinations were precisely adjusted within the dual RT-RAA system to balance amplification efficiency and maintain consistent levels of amplification in crude plant samples. Utilizing commercially accessible small-scale equipment and following a streamlined optimization strategy, the assay achieved a limit of detection of 0.32 copies/μL of target genes in the reaction. Importantly, it demonstrated no cross-reactivity with other plant pathogens, thereby affirming the high sensitivity and specificity of the developed dual RT-RAA-LFS detection assay. Moreover, the entire process took only 25 min from sample collection to the visible presentation of results. The assay was validated with 60 field samples and 10 seed samples, producing results consistent with reverse transcription quantitative polymerase chain reaction (RT-qPCR). Notably, it successfully detected PMMoV in systemic leaves without visible symptoms three days post-inoculation, underscoring its effectiveness in early disease detection. This streamlined strategy offers a valuable approach for rapid, low-cost, and highly sensitive on-site simultaneous detection of RNA genome-contained PMMoV and DNA genome-contained Colletotrichum species.</p>","PeriodicalId":435,"journal":{"name":"Talanta","volume":null,"pages":null},"PeriodicalIF":5.6000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Talanta","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1016/j.talanta.2024.126908","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/18 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Ensuring the detection sensitivity of both RNA-derived and DNA-derived target genes in a single reaction has posed a significant challenge for on-site detection of plant pathogens. This challenge was addressed by developing a one-tube dual RT-RAA assay combined with LFS for the rapid on-site detection of pepper mild mottle virus (PMMoV) and four Colletotrichum species causing anthracnose in Solanaceous crops. By testing four different combinations of primer groups, two combinations were precisely adjusted within the dual RT-RAA system to balance amplification efficiency and maintain consistent levels of amplification in crude plant samples. Utilizing commercially accessible small-scale equipment and following a streamlined optimization strategy, the assay achieved a limit of detection of 0.32 copies/μL of target genes in the reaction. Importantly, it demonstrated no cross-reactivity with other plant pathogens, thereby affirming the high sensitivity and specificity of the developed dual RT-RAA-LFS detection assay. Moreover, the entire process took only 25 min from sample collection to the visible presentation of results. The assay was validated with 60 field samples and 10 seed samples, producing results consistent with reverse transcription quantitative polymerase chain reaction (RT-qPCR). Notably, it successfully detected PMMoV in systemic leaves without visible symptoms three days post-inoculation, underscoring its effectiveness in early disease detection. This streamlined strategy offers a valuable approach for rapid, low-cost, and highly sensitive on-site simultaneous detection of RNA genome-contained PMMoV and DNA genome-contained Colletotrichum species.
期刊介绍:
Talanta provides a forum for the publication of original research papers, short communications, and critical reviews in all branches of pure and applied analytical chemistry. Papers are evaluated based on established guidelines, including the fundamental nature of the study, scientific novelty, substantial improvement or advantage over existing technology or methods, and demonstrated analytical applicability. Original research papers on fundamental studies, and on novel sensor and instrumentation developments, are encouraged. Novel or improved applications in areas such as clinical and biological chemistry, environmental analysis, geochemistry, materials science and engineering, and analytical platforms for omics development are welcome.
Analytical performance of methods should be determined, including interference and matrix effects, and methods should be validated by comparison with a standard method, or analysis of a certified reference material. Simple spiking recoveries may not be sufficient. The developed method should especially comprise information on selectivity, sensitivity, detection limits, accuracy, and reliability. However, applying official validation or robustness studies to a routine method or technique does not necessarily constitute novelty. Proper statistical treatment of the data should be provided. Relevant literature should be cited, including related publications by the authors, and authors should discuss how their proposed methodology compares with previously reported methods.