Miriam Blanco-Ces, Ana de-Castro-Rios, Angela Lopez-Rabuñal, Maria Cobo-Golpe, Angelines Cruz, Elena Lendoiro
{"title":"Rapid Analytical Method for Quantification of Gamma-Hydroxybutyrate (GHB) in Hair by UPLC-MS/MS.","authors":"Miriam Blanco-Ces, Ana de-Castro-Rios, Angela Lopez-Rabuñal, Maria Cobo-Golpe, Angelines Cruz, Elena Lendoiro","doi":"10.1002/dta.3798","DOIUrl":null,"url":null,"abstract":"<p><p>Gamma-hydroxybutyrate (GHB), an endogenous compound related to the neurotransmitter gamma-aminobutyric acid (GABA), is used as a therapeutic and recreational drug and as a \"weapon\" in drug-facilitated crimes. The very short window of detection of GHB in conventional matrices (blood and urine) makes necessary the use of alternative matrices like hair. Hair has a long window of detection and the possibility to perform segmental analysis, which makes it very useful for proving GHB intake. In the present work, a method for quantification of GHB in hair was developed and validated. Hair (10 mg) was washed twice with dichloromethane and then incubated at room temperature with Milli-Q water in an ultrasound bath for 30 min. Analysis was performed by UPLC-MS/MS using a CORTECS UPLC HILIC (1.6 μm), 2.1 × 100-mm column, and a gradient with acetonitrile and ammonium acetate (10 mM) at pH 6.0, with a total run-time of 10 min. For detection, a triple quadrupole mass spectrometer in ESI negative mode was used. The method was validated, following the criteria established in the \"AAFS Standard Practices for Method Validation in Forensic Toxicology\" guideline, obtaining satisfactory results for linearity (0.5-50 ng/mg), accuracy (95.0%-103.2%), imprecision (< 10.2%), limit of detection (0.1 ng/mg) and quantification (0.5 ng/mg), exogenous selectivity (no interferences), matrix effect (less than -44.2%), extraction efficiency (> 86.4%), process efficiency (> 46.1%), and autosampler stability (< 4.3%). The method was used for the analysis of 26 authentic hair samples, 25 from non-drug users, obtaining values between < LOQ and 6.25 ng/mg of endogenous GHB and 1 from a former GHB chronic user to prove abstinence.</p>","PeriodicalId":160,"journal":{"name":"Drug Testing and Analysis","volume":" ","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2024-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Drug Testing and Analysis","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/dta.3798","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
Gamma-hydroxybutyrate (GHB), an endogenous compound related to the neurotransmitter gamma-aminobutyric acid (GABA), is used as a therapeutic and recreational drug and as a "weapon" in drug-facilitated crimes. The very short window of detection of GHB in conventional matrices (blood and urine) makes necessary the use of alternative matrices like hair. Hair has a long window of detection and the possibility to perform segmental analysis, which makes it very useful for proving GHB intake. In the present work, a method for quantification of GHB in hair was developed and validated. Hair (10 mg) was washed twice with dichloromethane and then incubated at room temperature with Milli-Q water in an ultrasound bath for 30 min. Analysis was performed by UPLC-MS/MS using a CORTECS UPLC HILIC (1.6 μm), 2.1 × 100-mm column, and a gradient with acetonitrile and ammonium acetate (10 mM) at pH 6.0, with a total run-time of 10 min. For detection, a triple quadrupole mass spectrometer in ESI negative mode was used. The method was validated, following the criteria established in the "AAFS Standard Practices for Method Validation in Forensic Toxicology" guideline, obtaining satisfactory results for linearity (0.5-50 ng/mg), accuracy (95.0%-103.2%), imprecision (< 10.2%), limit of detection (0.1 ng/mg) and quantification (0.5 ng/mg), exogenous selectivity (no interferences), matrix effect (less than -44.2%), extraction efficiency (> 86.4%), process efficiency (> 46.1%), and autosampler stability (< 4.3%). The method was used for the analysis of 26 authentic hair samples, 25 from non-drug users, obtaining values between < LOQ and 6.25 ng/mg of endogenous GHB and 1 from a former GHB chronic user to prove abstinence.
期刊介绍:
As the incidence of drugs escalates in 21st century living, their detection and analysis have become increasingly important. Sport, the workplace, crime investigation, homeland security, the pharmaceutical industry and the environment are just some of the high profile arenas in which analytical testing has provided an important investigative tool for uncovering the presence of extraneous substances.
In addition to the usual publishing fare of primary research articles, case reports and letters, Drug Testing and Analysis offers a unique combination of; ‘How to’ material such as ‘Tutorials’ and ‘Reviews’, Speculative pieces (‘Commentaries’ and ‘Perspectives'', providing a broader scientific and social context to the aspects of analytical testing), ‘Annual banned substance reviews’ (delivering a critical evaluation of the methods used in the characterization of established and newly outlawed compounds).
Rather than focus on the application of a single technique, Drug Testing and Analysis employs a unique multidisciplinary approach to the field of controversial compound determination. Papers discussing chromatography, mass spectrometry, immunological approaches, 1D/2D gel electrophoresis, to name just a few select methods, are welcomed where their application is related to any of the six key topics listed below.