Preparation and evaluation of Fe3O4@C@NiCo-LDH@CDs composites for magnetic solid-phase extraction of trace endocrine disruptors†

IF 2.7 3区 化学 Q2 CHEMISTRY, ANALYTICAL
Honglin Qin, Ruozhu Xu, Lizhen Qiao, Xupeng Zhai, Peixin Guo, Chen Li and Bingyan Han
{"title":"Preparation and evaluation of Fe3O4@C@NiCo-LDH@CDs composites for magnetic solid-phase extraction of trace endocrine disruptors†","authors":"Honglin Qin, Ruozhu Xu, Lizhen Qiao, Xupeng Zhai, Peixin Guo, Chen Li and Bingyan Han","doi":"10.1039/D4AY00864B","DOIUrl":null,"url":null,"abstract":"<p >The widespread use of endocrine disruptors (EDPs) has certain potential hazards to organisms and environments, and it is particularly important to develop effective pretreatment methods before detection of EDPs in complex samples. In this work, a novel magnetic nanocomposite decorated with layered double hydroxides (LDHs) and carbon dots (CDs) was designed and prepared for magnetic solid-phase extraction (MSPE) of EDPs (bisphenol S, bisphenol F, bisphenol A, bisphenol AF, diethylstilbestrol and 4-cumylphenol) combined with high-performance liquid chromatography-ultraviolet (HPLC-UV) detection. The prepared composites were characterized by field emission scanning electron microscopy (SEM), X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FT-IR) and X-ray photoelectron spectroscopy (XPS), and the adsorption mechanism towards these EDPs might be mainly based on hydrogen bonds and π–π conjugation. Under the optimized conditions, the proposed method showed limits of detection within 0.05–0.50 μg L<small><sup>−1</sup></small> and limits of quantitation within 0.2–2.0 μg L<small><sup>−1</sup></small>, and good linearity (<em>R</em><small><sup>2</sup></small> ≥ 0.9975) was presented in the range of 0.2–200 μg L<small><sup>−1</sup></small>. Finally, the Fe<small><sub>3</sub></small>O<small><sub>4</sub></small>@C@NiCo-LDH@CDs composite-based MSPE-HPLC-UV method was applied for enrichment and determination of EDPs in water, milk, and tea beverage samples with recoveries in the range of 81.2–119.8% and relative standard deviations below 9.7%.</p>","PeriodicalId":64,"journal":{"name":"Analytical Methods","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2024-08-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Methods","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2024/ay/d4ay00864b","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The widespread use of endocrine disruptors (EDPs) has certain potential hazards to organisms and environments, and it is particularly important to develop effective pretreatment methods before detection of EDPs in complex samples. In this work, a novel magnetic nanocomposite decorated with layered double hydroxides (LDHs) and carbon dots (CDs) was designed and prepared for magnetic solid-phase extraction (MSPE) of EDPs (bisphenol S, bisphenol F, bisphenol A, bisphenol AF, diethylstilbestrol and 4-cumylphenol) combined with high-performance liquid chromatography-ultraviolet (HPLC-UV) detection. The prepared composites were characterized by field emission scanning electron microscopy (SEM), X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FT-IR) and X-ray photoelectron spectroscopy (XPS), and the adsorption mechanism towards these EDPs might be mainly based on hydrogen bonds and π–π conjugation. Under the optimized conditions, the proposed method showed limits of detection within 0.05–0.50 μg L−1 and limits of quantitation within 0.2–2.0 μg L−1, and good linearity (R2 ≥ 0.9975) was presented in the range of 0.2–200 μg L−1. Finally, the Fe3O4@C@NiCo-LDH@CDs composite-based MSPE-HPLC-UV method was applied for enrichment and determination of EDPs in water, milk, and tea beverage samples with recoveries in the range of 81.2–119.8% and relative standard deviations below 9.7%.

Abstract Image

用于磁性固相萃取痕量内分泌干扰物的 Fe3O4@C@NiCo-LDH@CDs 复合材料的制备与评估
内分泌干扰物(EDPs)的广泛使用对生物和环境具有一定的潜在危害,因此在复杂样品中检测 EDPs 之前开发有效的预处理方法尤为重要。在这项工作中,设计并制备了一种装饰有层状双氢氧化物(LDHs)和碳点(CDs)的新型磁性纳米复合材料,用于结合高效液相色谱-紫外(HPLC-UV)检测法对 EDPs(双酚 S、双酚 F、双酚 A、双酚 AF、二乙基己烷苯酚和 4-积基苯酚)进行磁性固相萃取(MSPE)。通过场发射扫描电子显微镜(SEM)、X 射线衍射(XRD)、傅立叶变换红外光谱(FT-IR)和 X 射线光电子能谱(XPS)对所制备的复合材料进行了表征。在优化条件下,该方法的检出限为0.05-0.50 μg L-1,定量限为0.2-2.0 μg L-1,在0.2-200 μg L-1范围内线性关系良好(R2≥0.9975)。最后,将基于Fe3O4@C@NiCo-LDH@CDs复合材料的MSPE-HPLC-UV方法用于水、牛奶和茶饮料样品中EDPs的富集和测定,回收率为81.2%~119.8%,相对标准偏差小于9.7%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Analytical Methods
Analytical Methods CHEMISTRY, ANALYTICAL-FOOD SCIENCE & TECHNOLOGY
CiteScore
5.10
自引率
3.20%
发文量
569
审稿时长
1.8 months
期刊介绍: Early applied demonstrations of new analytical methods with clear societal impact
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信